Services: Difference between revisions
→Tasks for each Lab User: added Mike Silva to requesting an orientation |
|||
| (20 intermediate revisions by 2 users not shown) | |||
| Line 36: | Line 36: | ||
For new institutions to gain access to the UCSB Nanofabrication Facility, please provide the following documents. Email the docs to both [[Claudia Gutierrez]] and the [[Brian Thibeault|Lab Director]]. |
For new institutions to gain access to the UCSB Nanofabrication Facility, please provide the following documents. Email the docs to both [[Claudia Gutierrez]] and the [[Brian Thibeault|Lab Director]]. |
||
#Submit a |
#Submit a [//wiki.nanotech.ucsb.edu/w/images/7/79/Nanofabrication_Facility_Project_Description.xlsx Project Description (download)] (contact info etc.) to the [[Brian Thibeault|Lab Director]]. |
||
#Nanofab staff acceptance |
#Nanofab staff acceptance |
||
#[//wiki.nanotech.ucsb.edu/w/images/a/a2/UCSB-Facilities-Use-Agreement.pdf UCSB Facility Use Agreement (download)] signed by an official company signatory (attached form) |
#[//wiki.nanotech.ucsb.edu/w/images/a/a2/UCSB-Facilities-Use-Agreement.pdf UCSB Facility Use Agreement (download)] signed by an official company signatory (attached form) |
||
| Line 59: | Line 59: | ||
#Email [[Claudia Gutierrez]] to request a UCSBNetID (required) and to gain access to the UCSB Learning Center for basic on-line safety training. |
#Email [[Claudia Gutierrez]] to request a UCSBNetID (required) and to gain access to the UCSB Learning Center for basic on-line safety training. |
||
#Take the [https://www.ehs.ucsb.edu/training/uc-laboratory-safety-fundamentals-initial-online UCSB EH&S online safety course] once you have gained access. |
#Take the [https://www.ehs.ucsb.edu/training/uc-laboratory-safety-fundamentals-initial-online UCSB EH&S online safety course] once you have gained access. |
||
#Request UCSB Nanofab orientation/training by the [[Brian Thibeault|lab manager]] with review of the lab policy which can be found at the following link: [[Lab Rules|NanoFab Lab Rules]] |
#Request UCSB Nanofab orientation/training by the [[Brian Thibeault|lab manager]] & [[Mike Silva|operations manager]] with review of the lab policy which can be found at the following link: [[Lab Rules|NanoFab Lab Rules]] |
||
#[[Frequently Asked Questions#What Supplies do I need to bring to the lab.3F|Please read this FAQ page (link here)]] for a list of items you may need to bring to the lab for your research. |
#[[Frequently Asked Questions#What Supplies do I need to bring to the lab.3F|Please read this FAQ page (link here)]] for a list of items you may need to bring to the lab for your research. |
||
| Line 71: | Line 71: | ||
#Submit a Detailed [//wiki.nanotech.ucsb.edu/w/images/7/79/Nanofabrication_Facility_Project_Description.xlsx project description (download)] to [Mailto:nanofab-job-inquiry@ece.ucsb.edu Demis D. John & Brian Thibeault] |
#Submit a Detailed [//wiki.nanotech.ucsb.edu/w/images/7/79/Nanofabrication_Facility_Project_Description.xlsx project description (download)] to [Mailto:nanofab-job-inquiry@ece.ucsb.edu Demis D. John & Brian Thibeault] |
||
#Nanofab staff acceptance |
#Nanofab staff acceptance |
||
# |
#[[Media:Facility-Use-MOU---Intercampus-UC-User.pdf|Facilities Use - Memorandum of Understanding - Inter-UC Campus Use (download)]] - signed by Individual lab users. [https://wiki.nanotech.ucsb.edu/w/images/7/7c/Attachment_A_-_UCSB_Master_Facilities_Use_Agreement_Labs.pdf Attachment A] Lists UCSB facilities covered by the agreement. |
||
====Tasks for each UC Lab User==== |
====Tasks for each UC Lab User==== |
||
| Line 87: | Line 87: | ||
===Important Info on Fabrication Services=== |
===Important Info on Fabrication Services=== |
||
*[https://www.nanotech.ucsb.edu/services#comp-k3rx7hk4 '''Rates are listed here''']. |
*[https://www.nanotech.ucsb.edu/services#comp-k3rx7hk4 '''Rates are listed here''']. |
||
**We bill for both "<u>''Use of Facility + Equipment''</u>" '''plus''' "''<u>Dedicated staff support</u>''" time per hour. |
|||
| ⚫ | |||
**We will only apply '''Academic/Gov't rates''' if the technical contact directing the work is at the academic/gov't institution we have a signed service agreement with. |
|||
*Any project must first be accepted by our Project Scientists. |
|||
| ⚫ | |||
*We have limited staff and are not a foundry, and we will only accept jobs that we are capable of performing with success. |
**We have limited staff and are not a foundry, and we will only accept jobs that we are capable of performing with success. |
||
* |
**We may be able to suggest other ways to get your devices made in our lab if Staff use is not appropriate for your project. |
||
*You are billed as if your own employee were using the lab regardless of results. We can provide only a rough estimate of time and cost. |
|||
*There is '''''no guarantee''''' of research results or success in fabrication. |
|||
*You will be <u>billed for the Actual time and materials required during the job</u>, regardless of project outcome. |
*You will be <u>billed for the Actual time and materials required during the job</u>, regardless of project outcome. |
||
| ⚫ | |||
**We can provide only a rough ''estimate'' of time and cost because it's an hourly service, not a "quote". |
|||
*We send out bills at the end of each month, with payment expected as Net30; Credit card payments are accepted. |
|||
| ⚫ | *[[Frequently Asked Questions#Publications acknowledging the Nanofab|Publications Policy]] - fabrication executed by NanoFab Staff is often significant "''intellectual contribution''". [[Frequently Asked Questions#Publications acknowledging the Nanofab|Acknowledgement of NanoFab use]] is required at minimum. |
||
===Request Remote Fabrication Services=== |
===Request Remote Fabrication Services=== |
||
| Line 104: | Line 107: | ||
====Paperwork for Fabrication Services==== |
====Paperwork for Fabrication Services==== |
||
4. Return the [//wiki.nanotech.ucsb.edu/w/images/1/1d/UCSB_Service_Agreement.pdf '''UCSB Service Agreement'''] (download) |
|||
*Requires signature from your institution - <u>signature authority required</u>, typically ''not'' the professor or graduate student. Business or Contracts Dept., for example. |
|||
| ⚫ | |||
4. Return the [//wiki.nanotech.ucsb.edu/w/images/1/1d/UCSB_Service_Agreement.pdf '''UCSB Service Agreement'''] (download) |
|||
*Requires signature from your institution (signature authority required) |
|||
*Only one agreement is needed per institution. Ask us to find out if your inst. already has one in place. |
*Only one agreement is needed per institution. Ask us to find out if your inst. already has one in place. |
||
*'''UC Users:''' this is not NOT needed. |
|||
3. Submit the [//wiki.nanotech.ucsb.edu/w/images/7/79/Nanofabrication_Facility_Project_Description.xlsx '''Project Info and Description Form'''] (download) to [Mailto:nanofab-job-inquiry@ece.ucsb.edu,claudia18@ucsb.edu?subject=Fab+Services+Project+Description Demis D. John and Claudia Gutierrez] |
|||
| ⚫ | |||
*If you are a '''UCSB Group''', we ''don't'' need the service agreement. from you, only the '''''Project Info & Description Form''''' (above). |
|||
*'''UC Users''' - in the Project Description, you will have to provide a valid Recharge Account number to bill against. |
|||
*If you are a '''group from another UC''', we don't need the Service Agreement, instead we need a different form: [[Services#Other U.C. Campuses|The Inter-Campus MOU]] (here is [https://wiki.nanotech.ucsb.edu/w/images/7/7c/Attachment_A_-_UCSB_Master_Facilities_Use_Agreement_Labs.pdf Attachment A]). |
|||
===='''Statement of Work'''==== |
===='''Statement of Work'''==== |
||
For each request, please provide a quick PPT/Word/similar doc explaining exactly what you need done, |
For each request, please provide a quick PPT/Word/similar doc explaining ''exactly'' what you need done ("SOW"). We will discuss this with you before starting the work, and our staff may use this document to answer questions that come up during processing. Your SOW should include: |
||
| ⚫ | |||
| ⚫ | |||
**We use the approx date as your BatchID |
|||
| ⚫ | |||
| ⚫ | |||
**Sample ID's/numbering is highly recommended if appropriate. |
|||
*Size/Shape of samples. Eg. "''4-inch wafers''" or "''irregular ~1cm pieces''" |
|||
*Exact processing steps to perform. Staff will assist filling in any missing details. |
*Exact processing steps to perform. Staff will assist filling in any missing details. |
||
**Please clearly state which steps UCSB Staff will perform, versus steps your staff will perform, if needed. |
|||
*Targets and acceptable tolerances for the main steps, eg. "''Deposit 500nm of SiO2, acceptable range 450-550nm (±10% tolerance)''". |
*Targets and acceptable tolerances for the main steps, eg. "''Deposit 500nm of SiO2, acceptable range 450-550nm (±10% tolerance)''". |
||
| ⚫ | |||
**Note that tight tolerances (<<10%) will require us to run additional calibrations at your expense, so please choose a tolerance that is ''required'' for your devices to work. |
**Note that tight tolerances (<<10%) will require us to run additional calibrations at your expense, so please choose a tolerance that you know is ''required'' for your devices to work. |
||
| ⚫ | |||
| ⚫ | |||
===== Example SOWs ===== |
|||
| ⚫ | |||
For some tools the programming/instructions can be fairly complex - below are examples for tools that require more detailed instructions: |
|||
*[https://docs.google.com/presentation/d/1mx8Jxu_4v2PnNiwqXvni8I1i4NWoCFMb?rtpof=true&usp=drive_fs Basic SOW example PPT: "''2025-09-15 InP Deep Etch v1.pptx''"]. |
|||
*An example PPT for Stepper lithography jobs can be found here: [[Media:UCSB ASML DUV Stepper - Programming Worksheet.pptx|UCSB_Stepper_-_Programming_Worksheet.pptx]] |
|||
*An example PPT for Dicing (die singulation) can be found here: [[Media:Dicing - Example Dicing Instructions for UC Santa Barbara v2.pptx|Dicing - Example Dicing Instructions for UC Santa Barbara v2.pptx]] |
|||
Latest revision as of 14:30, 1 October 2026
Procedures and paperwork to get your students/employees into the NanoFab.
If you are looking for fabrication services by NanoFab staff, please see this section.
Hourly rates can be found on this page.
Please choose the appropriate section:
Lab Orientation
The lab orientation takes between 1-2 hours and is scheduled based on new user demand.
The orientation will explain actual lab use, equipment scheduling and trainings, discuss safety policy, enter users into the access system, tour the gowning room area and explain any questions about lab or tool use. Please feel free to call or email to discuss in more detail. See the below sections for the additional info needed to attend a lab orientation.
Onboarding for out-of-town visitors
For lab users visiting from out of town, please start your scheduling with us at least 3-4 weeks in advance so we can help you schedule a lab orientation and tool trainings around your planned trip dates, and help make your trip efficient and productive. Contact Demis for advice on which tools to get trained on.
U.C. Santa Barbara Researchers
Applies to: UCSB faculty, post-docs, graduate students, undergraduates, interns etc.
- Contact the Lab Director, Brian Thibeault for lab access.
Industry and non-U.C. Academic Institutions
Applies to: Employees of Companies (for-profit), and researchers from Universities/Academic Institutions that are not part for the University of California system. This includes Government research labs in any country.
Follow ALL instructions below:
If you think your institution has previously sent people to use our lab, some of this paperwork may already be in place. Contact the Lab Director to find out if that is the case.
Paperwork for new Institutions (Non-UC)
For new institutions to gain access to the UCSB Nanofabrication Facility, please provide the following documents. Email the docs to both Claudia Gutierrez and the Lab Director.
- Submit a Project Description (download) (contact info etc.) to the Lab Director.
- Nanofab staff acceptance
- UCSB Facility Use Agreement (download) signed by an official company signatory (attached form)
- Provide a General Liability Insurance Certificate
- Commercial Form General Liability requirements:
- Combined Single Limit per Occurrence: $1,000,000
- General Aggregate, Bodily Injury, Property Damage: $2,000,000
- The Regents of the University of California must be named as an additional insured.
- An example certificate is attached (download). Your certificate should have the same basic format and information as shown. The certificate should be emailed to the Lab Director.
- The CERTIFICATE HOLDER shall be identified as follows:
- The Regents of the University of California
- Contracts & Property Office
- SAASB Bldg., Rm. 3203
- University of California
- Santa Barbara, CA 93106-2095
- Commercial Form General Liability requirements:
- Provide Proof of Workers’ Compensation Insurance or equivalent coverage. This is required under California state law. If the required certificate of insurance is not received and approved prior to the Facility User's intended use of facility, Facility User shall not be allowed to use University facilities.
Tasks for each Lab User
For EACH researcher that will enter the lab, please follow these directions:
- Fill out, sign, and return the UCSB Blanket Liability Waiver (download) to the Lab director
- Email Claudia Gutierrez to request a UCSBNetID (required) and to gain access to the UCSB Learning Center for basic on-line safety training.
- Take the UCSB EH&S online safety course once you have gained access.
- Request UCSB Nanofab orientation/training by the lab manager & operations manager with review of the lab policy which can be found at the following link: NanoFab Lab Rules
- Please read this FAQ page (link here) for a list of items you may need to bring to the lab for your research.
Other U.C. Campuses
Applies To: Researchers at other University of California campuses, apart from U.C Santa Barbara.
Follow ALL instructions below:
Paperwork for new UC institutions
For new UC institutions to gain access to the UCSB Nanofabrication Facility, please provide the following documents. Send the files to both Claudia Gutierrez and the Lab Director.
- Submit a Detailed project description (download) to Demis D. John & Brian Thibeault
- Nanofab staff acceptance
- Facilities Use - Memorandum of Understanding - Inter-UC Campus Use (download) - signed by Individual lab users. Attachment A Lists UCSB facilities covered by the agreement.
Tasks for each UC Lab User
For EACH researcher that will enter the lab, please follow these directions:
- Fill out, sign, and return the UCSB Blanket Liability Waiver (download) to the Lab director
- Email Claudia Gutierrez to request a UCSBNetID (required) and to gain access to the UCSB Learning Center for basic on-line safety training.
- Take the UCSB EH&S online safety course once you have gained access.
- Request UCSB Nanofab orientation/training by the lab manager with review of the lab policy which can be found at the following link: NanoFab Lab Rules
- Please read this FAQ page (link here) for a list of items you may need to bring to the lab for your research.
Fabrication Services by NanoFab Staff
Perform fabrication services via NanoFab staff, instead of your staff/employees entering our lab.
Important Info on Fabrication Services
- Rates are listed here.
- We bill for both "Use of Facility + Equipment" plus "Dedicated staff support" time per hour.
- We will only apply Academic/Gov't rates if the technical contact directing the work is at the academic/gov't institution we have a signed service agreement with.
- You will work directly with Demis or his staff to accept + schedule the work, if the project is accepted.
- We have limited staff and are not a foundry, and we will only accept jobs that we are capable of performing with success.
- We may be able to suggest other ways to get your devices made in our lab if Staff use is not appropriate for your project.
- There is no guarantee of research results or success in fabrication.
- You will be billed for the Actual time and materials required during the job, regardless of project outcome.
- We can provide only a rough estimate of time and cost because it's an hourly service, not a "quote".
- We send out bills at the end of each month, with payment expected as Net30; Credit card payments are accepted.
- Publications Policy - fabrication executed by NanoFab Staff is often significant "intellectual contribution". Acknowledgement of NanoFab use is required at minimum.
Request Remote Fabrication Services
Submitting jobs for "remote" fabrication services requires the following steps:
1. Contact us (email us) to determine project feasibility or ask questions.
2. Nanofab Staff acceptance of project.
Paperwork for Fabrication Services
4. Return the UCSB Service Agreement (download)
- Requires signature from your institution - signature authority required, typically not the professor or graduate student. Business or Contracts Dept., for example.
- Only one agreement is needed per institution. Ask us to find out if your inst. already has one in place.
- UC Users: this is not NOT needed.
3. Submit the Project Info and Description Form (download) to Demis D. John and Claudia Gutierrez
- No signatures required, only project info and contact info for internal billing purposes. A student cal fill this out.
- UC Users - in the Project Description, you will have to provide a valid Recharge Account number to bill against.
Statement of Work
For each request, please provide a quick PPT/Word/similar doc explaining exactly what you need done ("SOW"). We will discuss this with you before starting the work, and our staff may use this document to answer questions that come up during processing. Your SOW should include:
- Name your file something unique with a date like: "2024-08 SiO2 Dep v1.pptx"
- We use the approx date as your BatchID
- Revisions will update only the v1/2/3 number, but keep the BatchID the same.
- How many wafers to run and/or number of samples to be provided.
- Sample ID's/numbering is highly recommended if appropriate.
- Size/Shape of samples. Eg. "4-inch wafers" or "irregular ~1cm pieces"
- Exact processing steps to perform. Staff will assist filling in any missing details.
- Please clearly state which steps UCSB Staff will perform, versus steps your staff will perform, if needed.
- Targets and acceptable tolerances for the main steps, eg. "Deposit 500nm of SiO2, acceptable range 450-550nm (±10% tolerance)".
- It is common to not know the tolerance for research devices, so just leave that out and a "best effort" is usually acceptable.
- Note that tight tolerances (<<10%) will require us to run additional calibrations at your expense, so please choose a tolerance that you know is required for your devices to work.
Example SOWs
For some tools the programming/instructions can be fairly complex - below are examples for tools that require more detailed instructions:
- Basic SOW example PPT: "2025-09-15 InP Deep Etch v1.pptx".
- An example PPT for Stepper lithography jobs can be found here: UCSB_Stepper_-_Programming_Worksheet.pptx
- An example PPT for Dicing (die singulation) can be found here: Dicing - Example Dicing Instructions for UC Santa Barbara v2.pptx