Deep UV Optical Microscope (Olympus): Difference between revisions

From UCSB Nanofab Wiki
Jump to navigation Jump to search
Content deleted Content added
m added model field
link to LEXT wiki page
 
(7 intermediate revisions by 2 users not shown)
Line 1: Line 1:
{{tool|{{PAGENAME}}
{{tool2|{{PAGENAME}}
|picture=UVOlympus.jpg
|picture=UVOlympus.jpg
|type = Inspection, Test and Characterization
|type = Inspection, Test and Characterization
|super= Tony Bosch
|super= Tony Bosch
|super2= Demis D. John
|location=Bay 7
|location=Bay 7
|description =
|description = Deep-Ultraviolet (250nm) Microscope
|manufacturer = Olympus
|manufacturer = Olympus
|materials =
|materials =
Line 10: Line 11:
|model= MX61A-DUV
|model= MX61A-DUV
}}
}}
'''DUV Camera is non-operational and unable to be repaired.'''
= About =
'''Please use the ~450nm Blue Laser scanning scope, the [[Laser Scanning Confocal M-scope (Olympus LEXT)|Olympus LEXT]] instead.'''
This system does general purpose imaging in the visible and also has high resolution/high magnification DUV imaging using 250nm light. Surface features less than 100nm can be resolved. The system has precision stage control and is fully computer controlled for image capture and sample manipulation. A Good system for CD measurements on wafer (250nm and above) without entry into the SEM.

==About==
This system does general purpose imaging in the visible and also has high resolution/high magnification DUV imaging using 250 nm light. Surface features less than 100nm can be resolved.

The system has precision motorized stage control and is fully computer controlled for image capture and sample manipulation.

A Good system for CD measurements on wafer (250nm and above) without entry into the SEM.

==Detailed Specifications==

*Microscope Objectives:
**5x, 10x, 20x, 50x, 100x, DUV-100x
*Software Control:
**Motorized Stage & Objective Turret
**Calibrated Measurements (calibrations fixed)
**Z-motor (focus height) measurement
*Filters:
**Bright Field / Dark Field (visible only)

==Examples==
[[File:Olympus MX61A-DUV res test 100x DUV v1.png|alt=DUV microscope image with 1µm scale bar|none|thumb|504x504px|100x DUV image taken with the Olympus MX61A-DUV, showing sub-micron resolution.]]

==Other Info==
'''''Equip > Characterization > <u>[[Microscopes]]</u>''''' - ''see a list of all our microscopes''

Latest revision as of 00:09, 6 November 2025

Deep UV Optical Microscope (Olympus)
Location Bay 7
Tool Type Inspection, Test and Characterization
Manufacturer Olympus
Model MX61A-DUV
Description Deep-Ultraviolet (250nm) Microscope

Primary Supervisor Tony Bosch
(805) 893-3486
bosch@ece.ucsb.edu

Secondary Supervisor

Demis D. John


Recipes


DUV Camera is non-operational and unable to be repaired. 
Please use the ~450nm Blue Laser scanning scope, the Olympus LEXT instead.

About

This system does general purpose imaging in the visible and also has high resolution/high magnification DUV imaging using 250 nm light. Surface features less than 100nm can be resolved.

The system has precision motorized stage control and is fully computer controlled for image capture and sample manipulation.

A Good system for CD measurements on wafer (250nm and above) without entry into the SEM.

Detailed Specifications

  • Microscope Objectives:
    • 5x, 10x, 20x, 50x, 100x, DUV-100x
  • Software Control:
    • Motorized Stage & Objective Turret
    • Calibrated Measurements (calibrations fixed)
    • Z-motor (focus height) measurement
  • Filters:
    • Bright Field / Dark Field (visible only)

Examples

DUV microscope image with 1µm scale bar
100x DUV image taken with the Olympus MX61A-DUV, showing sub-micron resolution.

Other Info

Equip > Characterization > Microscopes - see a list of all our microscopes