Wafer Cleaver (PELCO Flip-Scribe): Difference between revisions

From UCSB Nanofab Wiki
Jump to navigation Jump to search
Content deleted Content added
links to Mfg
changed room --> ESB 1111
 
(3 intermediate revisions by 2 users not shown)
Line 3: Line 3:
|type = Packaging
|type = Packaging
|super= Brian Thibeault
|super= Brian Thibeault
|location=ESB 1106?
|location=ESB 1111
|description = Manual Cleaving
|description = Manual Cleaving
|model = [https://www.tedpella.com/Material-Sciences_html/PELCO-FlipScribe.aspx PELCO Flip-Scribe]
|model = [https://www.tedpella.com/Material-Sciences_html/PELCO-FlipScribe.aspx PELCO Flip-Scribe]
Line 11: Line 11:
}}
}}
==About==
==About==
The LatticeAx is a manual cleaving system, with a diamond tip that scribes along the underside of the part/wafer. The user manually drags the part across the diamond scribe, using the guides and stops to push the part in a controlled, straight line.
The Flip-Scribe is a manual scribe+break cleaving system, with a diamond tip that scribes along the underside of the part/wafer. The user manually drags the part across the diamond scribe, using the guides and stops to push the part in a controlled, straight line.
Manual breaking tools are provided to perform the break after scribing.
Manual breaking tools are provided to perform the break after scribing.

Can scribe/break ~350µm thick sapphire wafers. Thicker/more difficult to cleave parts should be thinned down on the [[Mechanical Polisher (Allied)|Allied Polisher]] before cleaving.


==Detailed Specifications==
==Detailed Specifications==


* Wafer/Parts Sizes: 4" down to ~10mm
*Wafer/Parts Sizes: 4" down to ~10mm
*Digital microscope w/ laptop for finer alignment
*~100µm alignment accuracy


==Operating Procedures==
==Operating Procedures==


* [[LatticeAx SOP]] - To be added
*Flipscribe [[LatticeAx SOP|SOP]] - To be added




==Recipes==
==Recipes==


*Recipes > Packaging > '''[[Packaging Recipes#LatticeAx|To Be Added]]'''
*Recipes > Packaging > '''[[Packaging Recipes#LatticeAx|''To Be Added'']]'''


Be sure to also see the recipes for protecting your sample from dicing dust on the [[Packaging Recipes]] page.
Be sure to also see the recipes for protecting your sample from dicing dust on the [[Packaging Recipes|'''Packaging Recipes''']] page.

Latest revision as of 14:57, 13 December 2022

Wafer Cleaver (PELCO Flip-Scribe)
Tool Type Packaging
Location ESB 1111
Supervisor Brian Thibeault
Supervisor Phone (805) 893-2268
Supervisor E-Mail thibeault@ece.ucsb.edu
Description Manual Cleaving
Manufacturer TedPella Inc.
Model PELCO Flip-Scribe


About

The Flip-Scribe is a manual scribe+break cleaving system, with a diamond tip that scribes along the underside of the part/wafer. The user manually drags the part across the diamond scribe, using the guides and stops to push the part in a controlled, straight line. Manual breaking tools are provided to perform the break after scribing.

Can scribe/break ~350µm thick sapphire wafers. Thicker/more difficult to cleave parts should be thinned down on the Allied Polisher before cleaving.

Detailed Specifications

  • Wafer/Parts Sizes: 4" down to ~10mm
  • Digital microscope w/ laptop for finer alignment
  • ~100µm alignment accuracy

Operating Procedures

  • Flipscribe SOP - To be added


Recipes

Be sure to also see the recipes for protecting your sample from dicing dust on the Packaging Recipes page.