Thermal Evap 2 (Solder): Difference between revisions

From UCSB Nanofab Wiki
Jump to navigation Jump to search
Content deleted Content added
Biljana (talk | contribs)
Biljana (talk | contribs)
 
(74 intermediate revisions by 5 users not shown)
Line 1: Line 1:
{{tool|{{PAGENAME}}
{{tool2|{{PAGENAME}}
|picture=Thermal2.jpg
|picture=Thermal2.jpg
|type = Vacuum Deposition
|type = Vacuum Deposition
|super= Brian Lingg
|super= Michael Barreraz
|super2= Don Freeborn
|location=Bay 3
|location=Bay 3
|description = ?
|description = ?
Line 10: Line 11:
}}
}}


= About =
== About ==
Thermal evaporator #2 is the designated "Solder" evaporator. The tool is used primarily for solder materials including Gold, Indium and Tin. See the Recipes section below for other materials used.


Use this tool for materials with low melting temperatures, or for materials that have a high risk of contamination in the e-beam evaporators.
⚫
=Detailed Specifications=
*Standard 18" bell jar pumped by 8" Varian cryopump (HV8) driven by Ebara 2.1 compressor
*Low E-7 Torr ultimate pressure
*Rate Monitor: Maxtek TM-300
*Typical material rates: Al - 1 A/s @ 85 amps
**Au - 5 A/s @ 122 amps
**Cr - 2 A/s @ 85 amps
**Zn - 4.5 A/s @ 50 amps


⚫
== Detailed Specifications ==
= Materials Table =
Wafers up to 12" can be mounted.


==Documentation==
{| border="1" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center; font-size: 95%" class="collapsible collapsed wikitable"
*[//wiki.nanotech.ucsb.edu/w/images/b/b3/Thermal_Evaporator2.pdf Operating Instructions]
|-
*[https://wiki.nanofab.ucsb.edu/w/images/1/17/Thermal_Evaporator2-Normal_Fixture-_Indium_Deposition.pdf Using Normal Fixture]
! colspan=8 width=1300 height=35 bgcolor="#D0E7FF" align="center"|<div style="font-size: 150%;">Materials Table</div>
*[https://wiki.nanofab.ucsb.edu/w/images/d/d1/Thermal_Evaprator2-Cold_Fixture-Indium_Deposition.pdf Using Cold Fixture]
|- bgcolor="#D0E7FF"
*[https://wiki.nanofab.ucsb.edu/w/images/7/74/Thermal_Evap_2_pump_down_procedure-New-_5-29-25.pdf Temp Pump Down SOP as of 5-29-25]
! width="45" bgcolor="#D0E7FF" align="center" | '''Material'''

! width="45" bgcolor="#D0E7FF" align="center" | '''Symbol'''
== Recipes ==
! width="45" bgcolor="#D0E7FF" align="center" | '''Density, g/cm3'''
* [[Thermal Evaporation Recipes#Thermal Evaporator 2|Recipes > Thermal Evaporation Recipes > Thermal Evaporator 2]]
! width="45" bgcolor="#D0E7FF" align="center" | '''Z Ratio'''
** ''Visit this page for the materials table and evaporation parameters for all materials available.''
! width="45" bgcolor="#D0E7FF" align="center" | '''Tooling, %'''
* [https://wiki.nanofab.ucsb.edu/w/images/0/05/Sn_deposition_in_Thermal_Evaporator2.pdf Tin deposition]
! width="45" bgcolor="#D0E7FF" align="center" | '''Current, Amp'''

! width="45" bgcolor="#D0E7FF" align="center" | '''Dep.rate, A/sec'''
== Plot ==
! width="100" bgcolor="#D0E7FF" align="center" | '''Comments'''
* [https://wiki.nanofab.ucsb.edu/w/images/b/bb/Thermal_Evaporator2-Plot.png Plot for Indium Deposition]
|-

Latest revision as of 21:35, 19 June 2025

Thermal Evap 2 (Solder)
Location Bay 3
Tool Type Vacuum Deposition
Manufacturer Custom
Description ?

Primary Supervisor Michael Barreraz
(805) 893-4147
mikebarreraz@ece.ucsb.edu

Secondary Supervisor

Don Freeborn


Recipes Vacuum Deposition Recipes

SignupMonkey: Sign up for this tool


About

Thermal evaporator #2 is the designated "Solder" evaporator. The tool is used primarily for solder materials including Gold, Indium and Tin. See the Recipes section below for other materials used.

Use this tool for materials with low melting temperatures, or for materials that have a high risk of contamination in the e-beam evaporators.

Detailed Specifications

Wafers up to 12" can be mounted.

Documentation

Recipes

Plot