PECVD1 Recipes: Difference between revisions

From UCSB Nanofab Wiki
Jump to navigation Jump to search
Line 18: Line 18:
*[https://docs.google.com/spreadsheet/ccc?key=0AnwBU1s4JQo2dEttR2JSTkRoamR0SUZ4bE5QUW9uS2c&usp=sharing SiO<sub>2</sub> 1000A Thickness uniformity 2014]
*[https://docs.google.com/spreadsheet/ccc?key=0AnwBU1s4JQo2dEttR2JSTkRoamR0SUZ4bE5QUW9uS2c&usp=sharing SiO<sub>2</sub> 1000A Thickness uniformity 2014]


*Deposition rate~35.22nm/min (users must calibrate this prior to critical deps)
*Deposition rate~35.24nm/min (users must calibrate this prior to critical deps)
*HF e.r.~646nm/min
*HF e.r.~639nm/min
*Stress~-407MPa
*Stress~-415MPa
*Refractive Index~1.460
*Refractive Index~1.461


== SiO<sub>x</sub>N<sub>y</sub> deposition (PECVD #1) ==
== SiO<sub>x</sub>N<sub>y</sub> deposition (PECVD #1) ==

Revision as of 15:39, 14 October 2014

PECVD 1 (PlasmaTherm 790)

SiN deposition (PECVD #1)

  • Deposition rate~11.25nm/min (users must calibrate this prior to critical deps)
  • HF e.r.~89nm/min
  • Stress~446MPa
  • Refractive Index~1.940

SiO2 deposition (PECVD #1)

  • Deposition rate~35.24nm/min (users must calibrate this prior to critical deps)
  • HF e.r.~639nm/min
  • Stress~-415MPa
  • Refractive Index~1.461

SiOxNy deposition (PECVD #1)

  • Deposition rate~14.50nm/min (users must calibrate this prior to critical deps)
  • HF e.r.~399nm/min
  • Stress~145MPa
  • Refractive Index~1.714