m →SiO2 Etching (Panasonic 1): added etch rate, unknown selectivity |
→SiO2 Etching (Panasonic 2): linked to ICP#1 params |
||
| Line 49: | Line 49: | ||
==SiO<sub>2</sub> Etching (Panasonic 2)== |
==SiO<sub>2</sub> Etching (Panasonic 2)== |
||
*[[media:Panasonic2-SiOx-Recipe.pdf|SiO<sub>2</sub> Vertical Etch Recipe - CHF<sub>3</sub>]] |
*[[media:Panasonic2-SiOx-Recipe.pdf|SiO<sub>2</sub> Vertical Etch Recipe - CHF<sub>3</sub>]] |
||
**Direct copy of "SiOVert" from ICP#1, [[ICP_Etching_Recipes#SiO2_Etching_.28Panasonic_1.29|see parameters there]]. |
|||
*[[media:33-Etching_SiO2_with_Vertical_Side-wall.pdf|SiO<sub>2</sub> Vertical Etch Recipe#2 - CF<sub>4</sub>/CHF<sub>3</sub>]] |
*[[media:33-Etching_SiO2_with_Vertical_Side-wall.pdf|SiO<sub>2</sub> Vertical Etch Recipe#2 - CF<sub>4</sub>/CHF<sub>3</sub>]] |
||
*[[media:Panasonic2-ICP-Plasma-Etch-SiO2-nanoscale-rev1.pdf|SiO<sub>2</sub> Nanoscale Etch Recipe - CHF<sub>3</sub>/O<sub>2</sub>]] |
*[[media:Panasonic2-ICP-Plasma-Etch-SiO2-nanoscale-rev1.pdf|SiO<sub>2</sub> Nanoscale Etch Recipe - CHF<sub>3</sub>/O<sub>2</sub>]] |
||
Revision as of 23:45, 19 September 2017
Back to Dry Etching Recipes.
Si Deep RIE (PlasmaTherm/Bosch Etch)
Bosch and Release Etch (Si Deep RIE)
Single-step Si Etching (not Bosch Process!) (Si Deep RIE)
ICP Etch 1 (Panasonic E626I)
SiO2 Etching (Panasonic 1)
- SiO2 Vertical Etch Recipe Parameters - CHF3
- Etch rate ≈ 2300Å/min (users must calibrate)
- Selectivity (SiO2:Photoresist) ≈ greater than 1:1 (users must calibrate)
- SiO2 CHF3 Etch Variations
SiNx Etching (Panasonic 1)
Al Etch (Panasonic 1)
Cr Etch (Panasonic 1)
Ti Etch (Panasonic 1)
W-TiW Etch (Panasonic 1)
GaAs-AlGaAs Etch (Panasonic 1)
- GaAs-Nanoscale Etch Recipe - PR mask - Cl2-BCl3-Ar
- AlGaAs Etch Recipes - Cl2N2
- GaAs DRIE via Etch Recipes - Cl2-BCl3-Ar PR passivation
GaN Etch (Panasonic 1)
SiC Etch (Panasonic 1)
Sapphire Etch (Panasonic 1)
ICP Etch 2 (Panasonic E640)
Recipes starting points for materials without processes listed can be obtained from Panasonic1 recipe files. The chambers are slightly different, but essentially the same, requiring only small program changes to obtain similar results.
SiO2 Etching (Panasonic 2)
- SiO2 Vertical Etch Recipe - CHF3
- Direct copy of "SiOVert" from ICP#1, see parameters there.
- SiO2 Vertical Etch Recipe#2 - CF4/CHF3
- SiO2 Nanoscale Etch Recipe - CHF3/O2
SiNx Etching (Panasonic 2)
Al Etch (Panasonic 2)
GaAs Etch (Panasonic 2)
ICP-Etch (Unaxis VLR)
GaAs-AlGaAs Etch (Unaxis VLR)
InP-InGaAs-InAlAs Etch (Unaxis VLR)
- InP Etch Recipe (Cl2N2Ar 200C)
- InP-based Material Etch Profile (Cl2N2Ar200C)
- Unaxis InP Etch Recipe (Cl2H2 Ar 200C) Parameters
- InP-InGaAs Etch Profile (Cl2H2 Ar 200C)
- InGaAs-InAlAs Etch Issure (Cl2H2 Ar 200C)
- InP Etch (Cl2H2Ar 200C)2-17-2016
- InP Etch (Cl2H2Ar 200C) Start on 6-3-2016
- Lower etch-rate InP Etch (Cl2N2 200C)