Wafer Bonder (SUSS SB6-8E): Difference between revisions
Jump to navigation
Jump to search
Content deleted Content added
Freeborn d (talk | contribs) |
No edit summary |
||
| Line 2: | Line 2: | ||
|picture=WaferBonder.jpg |
|picture=WaferBonder.jpg |
||
|type = Thermal Processing |
|type = Thermal Processing |
||
|super= |
|super= Lee Sawyer |
||
|phone=(805)839-3918x216 |
|phone=(805)839-3918x216 |
||
|location=Bay 7 |
|location=Bay 7 |
||
Revision as of 17:52, 15 April 2020
|
About
This is Karl-Suss model SB-6 substrate bonder. Wafer bonding of pieces to 6” wafers can be done at pressures from 5e-5 to 3e3 mBar and from 50°C to 550°C. This tool mates with the Karl-Suss MA-6 aligner to allow for aligned bonding. Forces up to 20 kN for a 150 mm wafer size are available. The system supports thermal compression as well as anodic bonding (up to 2000 V). The system is computer controlled with a windows environment allowing for multiple recipe steps and saving of recipes and data. The system is configured for manual loading of wafers.
Detailed Specifications
- Wafer bonding from 50°C to 550°C, +/- 5 degrees accuracy, +/- 3% uniformity
- Upper and lower heating of samples
- 5e-5 to 3e3 Torr environment bonding pressure, with Nitrogen
- Sample size: pieces to 6” wafers, aligned bonding by using MA/BA-6 aligner
- Anodic bonding to 2000 V
- Windows-based computer control
- Wafer bonder currently set up for 4" wafers
