Microscopes: Difference between revisions

From UCSB Nanofab Wiki
Jump to navigation Jump to search
Content deleted Content added
added info for microscope 2 + 3
→Microscope #4: (Bay 6): info on olympus uscopes
Line 25: Line 25:
* [https://www.nanotech.ucsb.edu/wiki/images/8/80/Nikon-Microscope-Manual.pdf Manual for Nikon Eclipse L200D]
* [https://www.nanotech.ucsb.edu/wiki/images/8/80/Nikon-Microscope-Manual.pdf Manual for Nikon Eclipse L200D]
* Trinocular: Binoc. + Camera (Mutually Exclusive)
* Trinocular: Binoc. + Camera (Mutually Exclusive)
* ProgResvideo/photo capture & measurement
* ProgRes video/photo capture & measurement
* 5x, 10x, 20x, 50x, 100x, 150x
* Objectives: 5x, 10x, 20x, 50x, 100x, 150x
* Filters: Green, ND
* Filters: Green, ND
* Bright/Dark Field
* Bright/Dark Field
* Differential Interference Contrast (DIC/Nomarski)
* Differential Interference Contrast (DIC/Nomarski)
* Top/Bottom Illumination
* Top Illumination


=== Microscope #4: (Bay 6) ===
=== Microscope #4: (Bay 6) ===
* Trinocular: Binoc. + Camera (Mutually Exclusive)
* TBD
* ProgRes video/photo capture & measurement
* Objectives: 5x, 10x, 20x, 50x, 100x, 150x
* Filters: Green, ND
* Bright/Dark Field
* Differential Interference Contrast (DIC/Nomarski)
* Top/Bottom Illumination


==Olympus==
==Olympus==

The lab currently has two Olympus microscopes:
* [https://www.nanotech.ucsb.edu/wiki/images/2/28/Nikon-Microscope-OptiPhot-Manual.pdf Microscope #1: Olympus Optiphot-2 (Bay 3)]
=== [https://www.nanotech.ucsb.edu/wiki/images/2/28/Nikon-Microscope-OptiPhot-Manual.pdf Microscope #1: Olympus Optiphot-2 (Bay 3)] ===
* ''To be added''
⚫
* [[Fluorescence Microscope (Olympus MX51)|Fluorescence Microscope: Olympus MX51 (Bay 6)]]

⚫
* [[Deep UV Optical Microscope (Olympus)|DUV Microscope: Olympus MX61A-DUV (Bay 7)]]
⚫
=== [[Fluorescence Microscope (Olympus MX51)|Fluorescence Microscope: Olympus MX51 (Bay 6)]] ===
⚫
** ''Motorized Stage/Turret, Software control with Calibrated measurements, Deep-UV Light source+Camera for DUV-100x high res. imaging/measurement.''
* See the wiki page for the [[Fluorescence Microscope (Olympus MX51)|Olympus MX51]]
* Trinocular: Binoc. + Camera (Mutually Exclusive)
* Native photo/video capture & calibrated measurement
* Objectives: 5x, 10x, 20x, 50x, 100x, 150x
* Filters: Green, ND
* Bright/Dark Field
* Differential Interference Contrast (DIC/Nomarski)
* Top/Bottom Illumination
* Three Fluorescence Filters

⚫
=== [[Deep UV Optical Microscope (Olympus)|DUV Microscope: Olympus MX61A-DUV (Bay 7)]] ===
⚫
''Motorized Stage/Turret, Software control with Calibrated measurements, Deep-UV Light source+Camera for DUV-100x high res. imaging/measurement.''


== [[Laser Scanning Confocal M-scope (Olympus LEXT)|Olympus LEXT Confocal Microscope]] ==
== [[Laser Scanning Confocal M-scope (Olympus LEXT)|Olympus LEXT Confocal Microscope]] ==

Revision as of 05:55, 18 April 2019

Microscopes
Tool Type Inspection, Test and Characterization
Location Bay 3, 6 & 7
Supervisor Tony Bosch
Supervisor Phone (805) 893-3486
Supervisor E-Mail bosch@ece.ucsb.edu
Description Optical Microscopes
Manufacturer Nikon (3) & Olympus (1)


Nikon

The lab currently has 3 Nikon Microscopes (Microscopes #2, #3 & #4). These are located in bays 6 and 7.

The scopes are connected to computers via Jenoptik ProgRes software which allows users to digitally capture images through the microscope and make calibrated measurements.

Microscope #2: (Bay 7)

  • Trinocular: Ocular Binoc. + Camera (Simultaneous)
  • ProgRes video/photo capture & measurement
  • Objectives: 5x, 10x, 20x, 50x, 100x, 150x
  • Filters: Green, ND
  • Bright/Dark Field
  • Differential Interference Contrast (DIC/Nomarski)
    • The DIC prism is installed on each objective and can't be removed, so even regular microscope images suffer from a slight double-image
  • Top Illumination

Microscope #3: Eclipse Nikon L200D (Bay 6)

  • Manual for Nikon Eclipse L200D
  • Trinocular: Binoc. + Camera (Mutually Exclusive)
  • ProgRes video/photo capture & measurement
  • Objectives: 5x, 10x, 20x, 50x, 100x, 150x
  • Filters: Green, ND
  • Bright/Dark Field
  • Differential Interference Contrast (DIC/Nomarski)
  • Top Illumination

Microscope #4: (Bay 6)

  • Trinocular: Binoc. + Camera (Mutually Exclusive)
  • ProgRes video/photo capture & measurement
  • Objectives: 5x, 10x, 20x, 50x, 100x, 150x
  • Filters: Green, ND
  • Bright/Dark Field
  • Differential Interference Contrast (DIC/Nomarski)
  • Top/Bottom Illumination

Olympus

Microscope #1: Olympus Optiphot-2 (Bay 3)

  • To be added

Fluorescence Microscope: Olympus MX51 (Bay 6)

  • See the wiki page for the Olympus MX51
  • Trinocular: Binoc. + Camera (Mutually Exclusive)
  • Native photo/video capture & calibrated measurement
  • Objectives: 5x, 10x, 20x, 50x, 100x, 150x
  • Filters: Green, ND
  • Bright/Dark Field
  • Differential Interference Contrast (DIC/Nomarski)
  • Top/Bottom Illumination
  • Three Fluorescence Filters

DUV Microscope: Olympus MX61A-DUV (Bay 7)

Motorized Stage/Turret, Software control with Calibrated measurements, Deep-UV Light source+Camera for DUV-100x high res. imaging/measurement.

Olympus LEXT Confocal Microscope

YOU ARE REQUIRED TO GET TRAINED on this tool before you are allowed to use it! Please contact the Tool Owner to get training.

The LEXT has a motorized stage, image stitching capabilities and some image measurement capabilities, in addition to the primary topographical measurement capabilities afforded by the laser-scanning confocal microscopy function.

See the main tool page for more info: Laser Scanning Confocal M-scope (Olympus LEXT)

Documentation