Dicing Saw (ADT): Difference between revisions
Jump to navigation
Jump to search
Content deleted Content added
→Recipes: corrected link to recipes |
→Detailed Specifications: deleted old SOP, Lee's SOP only |
||
| Line 18: | Line 18: | ||
==Detailed Specifications== |
==Detailed Specifications== |
||
* Maximum Wafer Size: 8" |
|||
* Parts mounted to UV-release tape for cutting |
|||
* Automated cut maps at multiple angles (0° and 90° typical) |
|||
* ~few micron alignment to on-wafer features. |
|||
* Thermocarbon Resnoid dicing blades provided by staff |
|||
==Operating Procedures== |
==Operating Procedures== |
||
*[https://wiki.nanotech.ucsb.edu/w/images/5/57/ADT_SOP_Rev_D.pdf ADT Dicing Saw Standard Operating Procedure] |
*[https://wiki.nanotech.ucsb.edu/w/images/5/57/ADT_SOP_Rev_D.pdf ADT Dicing Saw Standard Operating Procedure] |
||
*[[ADT 7100 - Initial Setup Before Cutting|Setting up the Saw before Cutting]] - Disregard and refer to SOP above |
|||
*[[ADT 7100 - Standard Dicing Procedure - Programmed Cut Map|Standard Dicing Procedure - Programmed Cut Map]] |
|||
*[[ADT 7100 - Standard Dicing Procedure - Single Cuts|Standard Dicing Procedure - Single Cuts]] |
|||
*[[ADT 7100 - Recovering an Old Recipe (2019)|Recovering an Old Recipe]] |
*[[ADT 7100 - Recovering an Old Recipe (2019)|Recovering an Old Recipe]] |
||
Revision as of 17:26, 23 September 2021
|
About
The ADT 7100 Dicing Saw is optimized for multi-angle dicing of thin, tight tolerance products up to 200 mm x 200 mm. It is currently setup for dicing up to 8” diameter wafers. Check the Dicing Saw Recipes page for the blades we currently stock.
An ADT WM-966 tape applicator & Ultron Systems UH104-8 UV lamp system is used to apply UV-release tape for securing die during dicing.
Contact the tool supervisor for blades and dicing frames for your group.
Detailed Specifications
- Maximum Wafer Size: 8"
- Parts mounted to UV-release tape for cutting
- Automated cut maps at multiple angles (0° and 90° typical)
- ~few micron alignment to on-wafer features.
- Thermocarbon Resnoid dicing blades provided by staff
Operating Procedures
Recipes
- Recipes > Packaging > Dicing Saw Recipes (ADT 7100)
Be sure to also see the recipes for protecting your sample from dicing dust, and mounting/unmounting.