SiN deposition (PECVD #1)

  • Deposition rate~11.30nm/min (users must calibrate this prior to critical deps)
  • HF e.r.~89nm/min
  • Stress~466MPa
  • Refractive Index~1.937

SiO2 deposition (PECVD #1)

  • Deposition rate~35.41nm/min (users must calibrate this prior to critical deps)
  • HF e.r.~669nm/min
  • Stress~-414MPa
  • Refractive Index~1.460