==Nikon==
==Nikon==
The Nikon scopes have 3rd party cameras that are connected to computers via AM Scope software which allows users to digitally capture images through the microscope and make calibrated measurements.
The Nikon scopes have 3rd party cameras that are connected to computers via AM Scope software which allows users to digitally capture images through the microscope and make calibrated measurements.

⚫
===Microscope #1: Nikon Optiphot-2 (Char. Lab, Room 1111)===

⚫
*Trinocular: Ocular Binoc. + Camera (Exclusive)
⚫
*LED Illuminator, Variable
⚫
*Objectives: ''Info to be added''
⚫
*Bright/Dark Field
⚫
*Top Reflected (Episcopic) & Bottom Transmission (Diascopic) Illumination
⚫
*AMScope 14MP Cameras with calibrated software for measurements. Software available for desktop measurements. [https://www.amscope.com/software-download Link here].
⚫
*User Manual: [https://www.nanotech.ucsb.edu/wiki/images/2/28/Nikon-Microscope-OptiPhot-Manual.pdf Nikon Optiphot-2 (PDF)]


===Microscope #2: Nikon Optiphot 200 (Bay 7)===
===Microscope #2: Nikon Optiphot 200 (Bay 7)===
Line 56: Line 46:


The lab has two general purpose Olympus microscopes, and two specialized microscopes that require training to use, although both of these can also be used for general imaging.
The lab has two general purpose Olympus microscopes, and two specialized microscopes that require training to use, although both of these can also be used for general imaging.
[[File:Microscope 01 Olympus BHMJL crop.png|alt=Photo of Microscope #01 in the Characterization lab, Room 1111|thumb|200x200px|Microscope #01 in the Characterization lab, Room 1111]]

⚫
===Microscope #1: Olympus BHMJL (Char. Lab, Room 1111)===

⚫
*Trinocular: Ocular Binoc. + Camera (Exclusive)
⚫
*LED Illuminator, Variable
⚫
*Objectives: ''Info to be added''
⚫
*Bright/Dark Field
⚫
*Top Reflected (Episcopic) & Bottom Transmission (Diascopic) Illumination
⚫
*AMScope 14MP Cameras with calibrated software for measurements. Software available for desktop measurements. [https://www.amscope.com/software-download Link here].
⚫
*User Manual: [https://www.nanotech.ucsb.edu/wiki/images/2/28/Nikon-Microscope-OptiPhot-Manual.pdf Nikon Optiphot-2 (PDF)]


===[[Fluorescence Microscope (Olympus MX51)|Fluorescence Microscope: Olympus MX51 (Bay 6)]]===
===Microscope #5: [[Fluorescence Microscope (Olympus MX51)|Fluorescence Microscope: Olympus MX51 (Bay 6)]]===


*See the wiki page for the [[Fluorescence Microscope (Olympus MX51)|Olympus MX51]] for full details
*See the wiki page for the [[Fluorescence Microscope (Olympus MX51)|Olympus MX51]] for full details
Line 71: Line 72:
*Three Fluorescence Filters (requires training, see main tool page for specs.)
*Three Fluorescence Filters (requires training, see main tool page for specs.)


===[[Deep UV Optical Microscope (Olympus)|DUV Microscope: Olympus MX61A-DUV (Bay 7)]]===
===Microscope #6: [[Deep UV Optical Microscope (Olympus)|DUV Microscope: Olympus MX61A-DUV (Bay 7)]]===
Please see the main tool page for detailed info on this microscope: [[Deep UV Optical Microscope (Olympus)]]
Please see the main tool page for detailed info on this microscope: [[Deep UV Optical Microscope (Olympus)]]
YOU ARE REQUIRED TO GET TRAINED on this tool before you are allowed to use it! Please contact the Tool Owner to get training.
YOU ARE REQUIRED TO GET TRAINED on this tool before you are allowed to use it! Please contact the Tool Owner to get training.

Revision as of 19:49, 3 December 2019

Microscopes
Tool Type Inspection, Test and Characterization
Location Bay 3, 6 & 7
Supervisor Tony Bosch
Supervisor Phone (805) 893-3486
Supervisor E-Mail bosch@ece.ucsb.edu
Description Optical Microscopes
Manufacturer Nikon & Olympus


Microscope Training - Use this guide for general usage info & the many advanced features available on most of our microscopes.

Nikon

The Nikon scopes have 3rd party cameras that are connected to computers via AM Scope software which allows users to digitally capture images through the microscope and make calibrated measurements.

Microscope #2: Nikon Optiphot 200 (Bay 7)

  • Trinocular: Ocular Binoc. + Camera (Simultaneous)
  • Objectives: 5x, 10x, 20x, 50x, 100x, 150x
  • Filters: Green, ND
  • Bright/Dark Field
  • Differential Interference Contrast (DIC/Nomarski)
    • DIC only available on 100x and 150x mags due to image quality reduction at low mags due to DIC prisms which were removed for low mags.
  • Top Reflected Illumination (Episcopic)
  • AMScope 14MP Cameras with calibrated software for measurements. Software available for desktop measurements. Link here.

Microscope #3: Nikon Eclipse L200 (Bay 6)

  • Manual for Nikon Eclipse L200D
  • Trinocular: Binoc. + Camera (Mutually Exclusive)
  • Objectives: 5x, 10x, 20x, 50x, 100x, 150x
  • Filters: Green, ND
  • Bright/Dark Field
  • Differential Interference Contrast (DIC/Nomarski)
  • Top Reflected Illumination (Episcopic)
  • AMScope 14MP Cameras with calibrated software for measurements. Software available for desktop measurements. Link here.

Microscope #4: Nikon Eclipse L200D (Bay 6)

  • Trinocular: Binoc. + Camera (Mutually Exclusive)
  • Objectives: 5x, 10x, 20x, 50x, 100x, 150x
  • Filters: Green, ND
  • Bright/Dark Field
  • Differential Interference Contrast (DIC/Nomarski)
  • Top Reflected (Episcopic) & Bottom Transmission (Diascopic) Illumination
  • AMScope 14MP Cameras with calibrated software for measurements. Software available for desktop measurements. Link here.

Olympus

The lab has two general purpose Olympus microscopes, and two specialized microscopes that require training to use, although both of these can also be used for general imaging.

Photo of Microscope #01 in the Characterization lab, Room 1111
Microscope #01 in the Characterization lab, Room 1111

Microscope #1: Olympus BHMJL (Char. Lab, Room 1111)

  • Trinocular: Ocular Binoc. + Camera (Exclusive)
  • LED Illuminator, Variable
  • Objectives: Info to be added
  • Bright/Dark Field
  • Top Reflected (Episcopic) & Bottom Transmission (Diascopic) Illumination
  • AMScope 14MP Cameras with calibrated software for measurements. Software available for desktop measurements. Link here.
  • User Manual: Nikon Optiphot-2 (PDF)

Microscope #5: Fluorescence Microscope: Olympus MX51 (Bay 6)

  • See the wiki page for the Olympus MX51 for full details
  • Trinocular: Binoc. + Camera (Simultaneous)
  • Native Olympus Stream Software:
    • Photo/video capture
    • Calibrated measurement (calibrations locked)
  • Objectives: 5x, 10x, 20x, 50x, 100x, 150x
  • Filters: Green, ND
  • Bright/Dark Field
  • Differential Interference Contrast (DIC/Nomarski)
  • Top (Episcopic) & Bottom (Diascopic) Illumination
  • Three Fluorescence Filters (requires training, see main tool page for specs.)

Microscope #6: DUV Microscope: Olympus MX61A-DUV (Bay 7)

Please see the main tool page for detailed info on this microscope: Deep UV Optical Microscope (Olympus)

YOU ARE REQUIRED TO GET TRAINED on this tool before you are allowed to use it! Please contact the Tool Owner to get training.
  • Motorized Stage + Objective Turret
  • Trinocular: Binoc. + Camera (Simultaneous)
  • Objectives: 5x, 10x, 20, 50x, 100x, DUV-100x
  • Filters: to be added
  • Native Olympus MX61 Software control & Camera
    • Calibrated measurements (calibrations locked)
    • Z (focus) measurement via motorized stage height
  • Deep-UV Light source + DUV Camera
    • DUV-100x sub-micron imaging/measurement

Olympus LEXT Confocal Microscope (Bay 4)

See the main tool page for complete info: Laser Scanning Confocal M-scope (Olympus LEXT)

YOU ARE REQUIRED TO GET TRAINED on this tool before you are allowed to use it! Please contact the Tool Owner to get training.
  • Motorized stage + Objective Turret
  • 100mm wafer stage
  • Native Olympus OLS2000 Software & Built-In Camera:
    • Calibrated measurement (calibrations locked)
    • Image stitching capabilities
  • 3D Laser-Scanning Confocal Microscopy capability:
    • 3D Topographical measurement (optical profilometry)
    • Surface roughness estimations (large roughness)
    • Thin-Film Film-Thickness Measurements (thicker films)

Procedures & Documentation