| Material | Symbol | Density, g/cm3 | Z Ratio | Tooling, % | Comments | |||||
| Aluminum | Al | 2.70 | 1.08 | |||||||
| Antimony | Sb | 6.620 | 0.768 | |||||||
| Arsenic | As | 5.73 | 0.996 | |||||||
| Beryllium | Be | 1.85 | 0.543 | |||||||
| Boron | B | 2.54 | 0.389 | |||||||
| Cadmium | Cd | 8.64 | 0.682 | |||||||
| Cadmium sulfide | CdS | 4.83 | 1.02 | |||||||
| Cadmium telluride | CdTe | 5.85 | 0.980 | |||||||
| Calcium fluoride | CaF2 | 3.18 | 0.775 | Used often | ||||||
| Carbon (graphite) | C | 2.25 | 3.26 | |||||||
| Chromium | Cr | 7.20 | 0.305 | 155 | Used often | |||||
| Cobalt | Co | 8.71 | 0.343 | |||||||
| Copper | Cu | 8.93 | 0.437 | |||||||
| Gallium | Ga | 5.93 | 0.593 | |||||||
| Gallium Arsenide | GaAs | 5.31 | 1.59 | |||||||
| Germanium | Ge | 5.35 | 0.516 | |||||||
| Gold | Au | 19.30 | 0.381 | Used often | ||||||
| Indium | In | 7.30 | 0.841 | 120 | USed often | |||||
| Indium antimonide | InSb | 5.76 | 0.769 | |||||||
| Iridium | Ir | 22.4 | 0.129 | |||||||
| Iron | Fe | 7.86 | 0.349 | |||||||
| Lead | Pb | 11.3 | 1.13 | |||||||
| Lead sulfide | PbS | 7.50 | 0.566 | |||||||
| Lithium fluoride | LiF | 2.638 | 0.778 | |||||||
| Magnesium | Mg | 1.74 | 1.61 | |||||||
| Magnesium oxide | MgO | 3.58 | 0.411 | |||||||
| Magnesium Fluoride | MgF2 | 3.00 ( should be 3.18) | 0.427( should be 0.637) | |||||||
| Manganese | Mn | 7.20 | 0.377 | |||||||
| Manganese(II) Sulfide | MnS | 3.99 | 0.94 | |||||||
| Mercury | Hg | 13.46 | 0.74 | |||||||
| Molybdenum | Mo | 10.2 | 0.257 | |||||||
| Nickel | Ni | 8.91 | 0.331 | Used often | ||||||
| Niobium | Nb | 8.578 | 0.492 | |||||||
| Niobium(V) Oxide | Nb2O5 | 4.47 | 1.00 | - | Palladium | Pd | 12.0 | 0.357 | ||
| Platinum | Pt | 21.4 | 0.245 | |||||||
| Potasium Cloride | KCl | 1.98 | 2.05 | |||||||
| Selenium | Se | 4.82 | 0.864 | |||||||
| Silicon | Si | 2.32 | 0.712 | |||||||
| Silicon(II) Oxide | SiO | 2.13 | 0.87 | |||||||
| Silicon dioxide (fused quarz) | SiO2 | 2.20 | 1.07 | |||||||
| Silver | Ag | 10.5 | 0.529 | |||||||
| Silver bromide | AgBr | 6.47 | 1.18 | |||||||
| Silver chloride | AgCl | 5.56 | 1.32 | |||||||
| Sodium | Na | 0.97 | 4.8 | |||||||
| Sodium chloride | NaCl | 2.17 | 1.57 | |||||||
| Tantalum | Ta | 16.6 | 0.262 | |||||||
| Tantalum(IV) oxide | Ta2O5 | 8.2 | 0.30 | |||||||
| Tin | Sn | 7.30 | 0.724 | Used often | ||||||
| Titanium | Ti | 4.50 | 0.628 | Used often | ||||||
| Titanium (IV) Oxide | TiO2 | 4.26 | 0.40 | |||||||
| Titanium Oxide | TiO | 4.90 | N/A | |||||||
| Tangsten | W | 19.3 | 0.163 | |||||||
| Tangsten carbide | WC | 15.6 | 0.151 | |||||||
| Zinc | Zn | 7.04 | 0.514 | Used often; Density should be 7.14 | ||||||
| Zinc Oxide | ZnO | 5.61 | 0.556 | |||||||
| Zinc Sulphide | ZnS | 4.09 | 0.775 | |||||||
| Zirconium | Zr | 6.51 | 0.60 | Should be 6.40 | ||||||
| Zirconium Oxide | ZrO2 | 5.6 | Should be 5.49 | |||||||