Recent changes

Jump to navigation Jump to search

Track the most recent changes to the wiki on this page.

Recent changes options Below are the changes since 7 July 2024, 05:16 (up to 50 shown). (Reset date selection)
Show last 50 | 100 | 250 | 500 changes in last 1 | 3 | 7 | 14 | 30 days
Hide registered users | Hide anonymous users | Hide my edits | Hide bots | Show minor edits
Show new changes starting from 04:10, 15 July 2024
   
List of abbreviations:
N
This edit created a new page (also see list of new pages)
m
This is a minor edit
b
This edit was performed by a bot
(±123)
The page size changed by this number of bytes

13 July 2024

     08:14  PECVD Recipes diffhist +962 John d talk contribs →‎ICP-PECVD (Unaxis VLR): added GapFill recipe Tag: Visual edit

12 July 2024

     11:25  Template:Announcements diffhist +37 Mehalana v talk contribs →‎Dicing Saw Service Visit

11 July 2024

     13:35  Lab Rules diffhist +89 John d talk contribs →‎Acid/Base and HF/TMAH/Bromine Processing: minor wording on HF TRIonic glove description to match shelf labeling Tag: Visual edit
     09:19  Lithography Recipes‎‎ 8 changes history +2,251 [John d‎; Gopimeena‎ (7×)]
     
09:19 (cur | prev) 0 Gopimeena talk contribs →‎Recipes Table (S-Cubed Flexi): Reverted back to previous view Tag: Visual edit
     
09:18 (cur | prev) -4 Gopimeena talk contribs →‎Recipes Table (S-Cubed Flexi): Cosmetics chages Tag: Visual edit
     
09:14 (cur | prev) +1 Gopimeena talk contribs →‎Recipes Table (S-Cubed Flexi) Tag: Visual edit
     
09:13 (cur | prev) -524 Gopimeena talk contribs →‎Recipes Table (S-Cubed Flexi) Tag: Visual edit
     
09:10 (cur | prev) 0 Gopimeena talk contribs Fixed some mistakes Tag: Visual edit
     
08:59 (cur | prev) +1,235 Gopimeena talk contribs Added all S-Cube recipes open for UCSB USER Tag: Visual edit
     
08:47 (cur | prev) +126 John d talk contribs →‎Recipes Table (S-Cubed Flexi): minor update s- headings for dev/dry-etch BARC Tag: Visual edit
     
08:33 (cur | prev) +1,417 Gopimeena talk contribs →‎Recipes Table (S-Cubed Flexi) Tag: Visual edit

10 July 2024

     23:15 User creation log User account Evgeneia talk contribs was created ‎
     19:28  Lithography Recipes‎‎ 3 changes history +2,489 [Gopimeena‎; John d‎ (2×)]
     
19:28 (cur | prev) +206 John d talk contribs →‎Recipes Table (S-Cubed Flexi): added rows between variations Tag: Visual edit
     
19:02 (cur | prev) +826 John d talk contribs →‎Automated Coat/Develop System Recipes (S-Cubed Flexi): added "variations" info Tag: Visual edit
     
17:24 (cur | prev) +1,457 Gopimeena talk contribs →‎Automated Coat/Develop System Recipes (S-Cubed Flexi) Tag: Visual edit
     16:25 User rights log John d talk contribs changed group membership for Gopimeena from (none) to staff ‎(new staff)

9 July 2024

     11:33  Sputtering Recipes‎‎ 2 changes history +575 [John d‎ (2×)]
     
11:33 (cur | prev) +238 John d talk contribs →‎SiO2 Uniformity: added table of stats Tag: Visual edit
     
11:26 (cur | prev) +337 John d talk contribs →‎Ion Beam Deposition (Veeco NEXUS): Added plot of Sio2 uniformity Tag: Visual edit
     11:25 Upload log John d talk contribs uploaded File:IBD - Deposition Uniformity across a 6-inch wafer 2010-06-15 v2.png

8 July 2024

     11:56  E-Beam 3 (Temescal) diffhist -8 Barreraz talk contribs →‎Documentation Tag: Visual edit
     11:55 Upload log Barreraz talk contribs uploaded File:EB-3 operation instructions 7-8-24.pdf
     10:24  Template:Announcements‎‎ 2 changes history +749 [Mehalana v‎ (2×)]
     
10:24 (cur | prev) -384 Mehalana v talk contribs
     
10:23 (cur | prev) +1,133 Mehalana v talk contribs