Recent changes
Jump to navigation
Jump to search
Track the most recent changes to the wiki on this page.
List of abbreviations:
- N
- This edit created a new page (also see list of new pages)
- m
- This is a minor edit
- b
- This edit was performed by a bot
- (±123)
- The page size changed by this number of bytes
16 July 2024
|
13:21 | Stepper Recipes 4 changes history +1,287 [John d (4×)] | |||
m |
|
13:21 (cur | prev) +26 John d talk contribs →Particle Checks Tag: Visual edit | |||
m |
|
13:19 (cur | prev) -10 John d talk contribs →Particle Checks Tag: Visual edit | |||
|
13:18 (cur | prev) +814 John d talk contribs →Process Control Data: added thumbnail images of the Cals | ||||
|
13:16 (cur | prev) +457 John d talk contribs →Process Control Data: added particle check section and explanation/fig Tag: Visual edit |
|
13:20 | (Upload log) [John d (3×)] | |||
|
13:20 John d talk contribs uploaded a new version of File:ASML Cal Particle Check.png (higher resolution) | ||||
|
13:17 John d talk contribs uploaded a new version of File:ASML Cal Particle Check.png (flipped wafers 180°, so Flat is Down like on software.) | ||||
|
13:14 John d talk contribs uploaded File:ASML Cal Particle Check.png |
15 July 2024
12:07 | Template:Announcements diffhist +374 Mehalana v talk contribs |
13 July 2024
08:14 | PECVD Recipes diffhist +962 John d talk contribs →ICP-PECVD (Unaxis VLR): added GapFill recipe |
12 July 2024
11 July 2024
13:35 | Lab Rules diffhist +89 John d talk contribs →Acid/Base and HF/TMAH/Bromine Processing: minor wording on HF TRIonic glove description to match shelf labeling |
|
09:19 | Lithography Recipes 8 changes history +2,251 [John d; Gopimeena (7×)] | |||
|
09:19 (cur | prev) 0 Gopimeena talk contribs →Recipes Table (S-Cubed Flexi): Reverted back to previous view Tag: Visual edit | ||||
|
09:18 (cur | prev) -4 Gopimeena talk contribs →Recipes Table (S-Cubed Flexi): Cosmetics chages Tag: Visual edit | ||||
|
09:14 (cur | prev) +1 Gopimeena talk contribs →Recipes Table (S-Cubed Flexi) Tag: Visual edit | ||||
|
09:13 (cur | prev) -524 Gopimeena talk contribs →Recipes Table (S-Cubed Flexi) Tag: Visual edit | ||||
|
09:10 (cur | prev) 0 Gopimeena talk contribs Fixed some mistakes Tag: Visual edit | ||||
|
08:59 (cur | prev) +1,235 Gopimeena talk contribs Added all S-Cube recipes open for UCSB USER Tag: Visual edit | ||||
|
08:47 (cur | prev) +126 John d talk contribs →Recipes Table (S-Cubed Flexi): minor update s- headings for dev/dry-etch BARC Tag: Visual edit | ||||
|
08:33 (cur | prev) +1,417 Gopimeena talk contribs →Recipes Table (S-Cubed Flexi) Tag: Visual edit |
10 July 2024
23:15 | User creation log User account Evgeneia talk contribs was created |
|
19:28 | Lithography Recipes 3 changes history +2,489 [Gopimeena; John d (2×)] | |||
|
19:28 (cur | prev) +206 John d talk contribs →Recipes Table (S-Cubed Flexi): added rows between variations Tag: Visual edit | ||||
|
19:02 (cur | prev) +826 John d talk contribs →Automated Coat/Develop System Recipes (S-Cubed Flexi): added "variations" info Tag: Visual edit | ||||
|
17:24 (cur | prev) +1,457 Gopimeena talk contribs →Automated Coat/Develop System Recipes (S-Cubed Flexi) Tag: Visual edit |
16:25 | User rights log John d talk contribs changed group membership for Gopimeena from (none) to staff (new staff) |
9 July 2024
|
11:33 | Sputtering Recipes 2 changes history +575 [John d (2×)] | |||
|
11:33 (cur | prev) +238 John d talk contribs →SiO2 Uniformity: added table of stats Tag: Visual edit | ||||
|
11:26 (cur | prev) +337 John d talk contribs →Ion Beam Deposition (Veeco NEXUS): Added plot of Sio2 uniformity Tag: Visual edit |
11:25 | Upload log John d talk contribs uploaded File:IBD - Deposition Uniformity across a 6-inch wafer 2010-06-15 v2.png |
8 July 2024
11:56 | E-Beam 3 (Temescal) diffhist -8 Barreraz talk contribs →Documentation |
11:55 | Upload log Barreraz talk contribs uploaded File:EB-3 operation instructions 7-8-24.pdf |
|
10:24 | Template:Announcements 2 changes history +749 [Mehalana v (2×)] | |||
|
10:24 (cur | prev) -384 Mehalana v talk contribs | ||||
|
10:23 (cur | prev) +1,133 Mehalana v talk contribs |