Thermal Evaporation Recipes: Difference between revisions

From UCSB Nanofab Wiki
Jump to navigation Jump to search
Content deleted Content added
Biljana (talk | contribs)
m moved In to bottom of table
(12 intermediate revisions by 2 users not shown)
Line 3: Line 3:
=[[Thermal Evaporator 1]]=
=[[Thermal Evaporator 1]]=


=Materials Table=
==Materials Table==


{| border="1" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center; font-size: 95%" class="collapsible collapsed wikitable"
{| border="1" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center; font-size: 95%" class="collapsible collapsed wikitable"
Line 180: Line 180:
|
|
|-
|-
|Strontium Fluoride
|StrontiumFluoride
|SrF<sub>2
|SrF<sub>2
|4.28
|4.28
Line 199: Line 199:
|-
|-
|ITO(IndiumTinOxide)
|ITO(IndiumTinOxide)
|In<sub>2O<sub>3-SnO<sub>2
|In<sub>2</sub>O<sub>3</sub> - SnO<sub>2
|5.43-7.14
|6.43-7.14
|0.841
|0.841
|
|
Line 208: Line 208:
|-
|-
|Permalloy
|Permalloy
|Ni<sub>0.1Fe<sub>0.2
|Ni<sub>0.1</sub>Fe<sub>0.2</sub>
|8.7
|8.7
|26.40
|26.40
Line 215: Line 215:
|0.1
|0.1
|
|
|-
|}


=[[Thermal Evaporator 2]]=
=[[Thermal Evaporator 2]]=


= Materials Table =
== Materials Table ==


{| border="1" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center; font-size: 95%" class="collapsible collapsed wikitable"
{| border="1" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center; font-size: 95%" class="collapsible collapsed wikitable"
Line 644: Line 644:
|
|
|
|
|-
|}

== In Deposition (Thermal Evaporator 2) ==
*[[media:Thermal evaporator 2-new Sheet1.pdf|Indium evaporation Data]]

Revision as of 00:00, 27 June 2018

Back to Vacuum Deposition Recipes.

Thermal Evaporator 1

Materials Table

Thermal Evaporator 2

Materials Table

In Deposition (Thermal Evaporator 2)