+ | {{tool2|{{PAGENAME}} |
|picture=ADT.jpg |
|picture=ADT.jpg |
||
|type = Packaging |
|type = Packaging |
||
− | |super= |
+ | |super= Lee Sawyer |
+ | |super2= Aidan Hopkins |
||
− | |phone= 805-893-3918x208 |
||
− | |location= |
+ | |location=Backend Lab: ESB 1111 |
− | |email=hopkins@ece.ucsb.edu |
||
|description = ADT Dicing Saw |
|description = ADT Dicing Saw |
||
+ | |model = ADT 7100 |
||
|manufacturer = Advanced Dicing Technologies Ltd. |
|manufacturer = Advanced Dicing Technologies Ltd. |
||
|materials = |
|materials = |
||
|toolid=49 |
|toolid=49 |
||
}} |
}} |
||
− | == |
+ | ==About== |
+ | The Model 7100 Series is a semi-automatic dicing saw. Semiconductor, glass, and plastic substrates of all types can be automatically or manually cut. This dicing Saw is optimized for multi-angle dicing of tight tolerance substrates up to 200 mm diameter in size. |
||
− | The ADT 7100 Dicing Saw is optimized for multi-angle dicing of thin, tight tolerance products up to 200 mm x 200 mm. It is currently setup for dicing up to 8” diameter wafers. Check the Dicing Saw Recipes page for the blades we currently stock. |
||
⚫ | |||
⚫ | |||
+ | An ADT WM-966 tape applicator is used to mount samples to UV-release tape for dicing and an Ultron Systems UH104-8 UV lamp system is used to release samples post dicing. |
||
⚫ | |||
− | * [[ADT 7100 - Standard Dicing Procedure - Programmed Cut Map|Standard Dicing Procedure - Programmed Cut Map]] |
||
− | * [[ADT 7100 - Standard Dicing Procedure - Single Cuts|Standard Dicing Procedure - Single Cuts]] |
||
+ | Contact Staff for blades and dicing frames for your group. |
||
− | ==== [[Recipe Recovery Procedure]] ==== |
||
− | # [[File:Image.png]]Click on the Programming Workspace |
||
− | # Go to any recipe |
||
− | # Click 'Recipe Import'[[File:Recipe import.png]] |
||
− | # Select 'd: [New Volume]' from 'Folder List'[[File:Volume d.jpg|533x533px]] |
||
− | # Open folder 'ADT'. Open Folder 'ADT-7100-8544150816'. Open folder 'db'. Open folder 'exports' |
||
− | # Find you recipe in the box to the right and double click on it |
||
− | # Verify group name is correct under 'Recipe Info' |
||
− | # Click 'OK' |
||
− | # Click 'Replace' |
||
− | # Repeat for additional recipes |
||
⚫ | |||
⚫ | |||
+ | |||
⚫ | |||
+ | *Maximum Wafer Size: 8" |
||
⚫ | |||
+ | *Parts mounted to UV-release tape for dicing |
||
+ | *Automated cut maps at multiple angles (0° and 90° typical) |
||
+ | *~Few micron alignment to on-wafer features. |
||
+ | *Thermocarbon Resnoid dicing blades provided by Staff |
||
+ | |||
⚫ | |||
+ | |||
+ | *[https://wiki.nanofab.ucsb.edu/w/images/5/54/ADT_SOP_Rev_J.pdf ADT Dicing Saw Standard Operating Procedure] |
||
+ | *[https://wiki.nanofab.ucsb.edu/w/images/5/5c/Post_Dicing_Tape_Expansion_SOP.pdf Post Dicing Tape Expansion] |
||
+ | *[https://wiki.nanofab.ucsb.edu/w/images/5/5a/Ultron_1042R_Film_specs.pdf Ultron Systems, Inc. 1042R Anti-Static Ultraviolet Film TDS] |
||
+ | *[[ADT 7100 - Recovering an Old Recipe (2019)|Recovering an Old Recipe]] |
||
+ | |||
+ | |||
⚫ | |||
+ | |||
+ | *Recipes > Packaging > '''[[Packaging Recipes#Dicing Saw Recipes .28ADT 7100.29|Dicing Saw Recipes (ADT 7100)]]''' |
||
+ | |||
⚫ |
Revision as of 14:10, 6 June 2024
|
About
The Model 7100 Series is a semi-automatic dicing saw. Semiconductor, glass, and plastic substrates of all types can be automatically or manually cut. This dicing Saw is optimized for multi-angle dicing of tight tolerance substrates up to 200 mm diameter in size.
Check the Dicing Saw Recipes page for the blades we currently stock.
An ADT WM-966 tape applicator is used to mount samples to UV-release tape for dicing and an Ultron Systems UH104-8 UV lamp system is used to release samples post dicing.
Contact Staff for blades and dicing frames for your group.
Detailed Specifications
- Maximum Wafer Size: 8"
- Parts mounted to UV-release tape for dicing
- Automated cut maps at multiple angles (0° and 90° typical)
- ~Few micron alignment to on-wafer features.
- Thermocarbon Resnoid dicing blades provided by Staff
Operating Procedures
- ADT Dicing Saw Standard Operating Procedure
- Post Dicing Tape Expansion
- Ultron Systems, Inc. 1042R Anti-Static Ultraviolet Film TDS
- Recovering an Old Recipe
Recipes
- Recipes > Packaging > Dicing Saw Recipes (ADT 7100)
Be sure to also see the recipes for protecting your sample from dicing dust, and mounting/unmounting.