Vacuum Deposition Recipes: Difference between revisions
Jump to navigation
Jump to search
(Changed PECVD2 levels and added proper internal links) |
(Added AuSn to Thermal evap 2) |
||
(19 intermediate revisions by 4 users not shown) | |||
Line 3: | Line 3: | ||
===Deposition Tools/Materials Table=== |
===Deposition Tools/Materials Table=== |
||
''The Key/Legend for this table's <code>A...R6</code> values is at the [[Vacuum Deposition Recipes#Process Ranking Table|<u>bottom of the page</u>]].'' |
|||
*<small>'''R''': ''Recipe is available. Clicking this link will take you to the recipe.''</small> |
|||
*<small>'''A''': ''Material is available for use, but no recipes are provided.''</small> |
|||
{| class="wikitable" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center;" border="1" |
{| class="wikitable" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center;" border="1" |
||
|- bgcolor="#d0e7ff" |
|- bgcolor="#d0e7ff" |
||
Line 37: | Line 34: | ||
|- |
|- |
||
! bgcolor="#d0e7ff" align="center" |Ag |
! bgcolor="#d0e7ff" align="center" |Ag |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R2]] |
||
| bgcolor="#eeffff" |<br> |
|||
| bgcolor="#eeffff" |{{Al/E3}} |
|||
| bgcolor="#eeffff" |{{Al/E4}} |
|||
| bgcolor="#eeffff" |[[Sputtering Recipes|A]] |
|||
| bgcolor="#eeffff" |[[Sputtering Recipes|A]] |
|||
| bgcolor="#eeffff" |<br> |
|||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 3 .28Temescal.29|R2]] |
|||
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 4 .28CHA.29|R2]] |
|||
| bgcolor="#eeffff" |[[Sputtering Recipes|R1]] |
|||
| bgcolor="#eeffff" |[[Sputtering Recipes|R1]] |
|||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |[[Thermal Evaporation Recipes#Thermal Evaporator 1|R1]] |
|||
| bgcolor="#eeffff" |[[Thermal Evaporation Recipes#Thermal Evaporator 2|R1]] |
|||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
Line 52: | Line 49: | ||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
|- |
|||
!AgBr |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|- |
|||
!AgCl |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|- |
|- |
||
! bgcolor="#d0e7ff" align="center" |Al |
! bgcolor="#d0e7ff" align="center" |Al |
||
|[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R2]] |
|||
|{{Al/E1}} |
|||
|<br> |
|<br> |
||
|[[E-Beam Evaporation Recipes#E-Beam 3 .28Temescal.29|R2]] |
|||
|{{Al/E3}} |
|||
|[[E-Beam Evaporation Recipes#E-Beam 4 .28CHA.29|R2]] |
|||
|{{Al/E4}} |
|||
|[[Sputtering Recipes| |
|[[Sputtering Recipes|R1]] |
||
| |
|[[Sputtering Recipes|R3]] |
||
|[[Sputtering Recipes|R1]] |
|||
|<br> |
|||
|R1 |
|||
|<br>[[Sputtering_Recipes#Ion_Beam_Deposition_.28Veeco_NEXUS.29|A]] |
|||
|[[Thermal Evaporation Recipes| |
|[[Thermal Evaporation Recipes#Thermal Evaporator 1|R3]] |
||
|[[Thermal Evaporation Recipes| |
|[[Thermal Evaporation Recipes#Thermal Evaporator 2|R1]] |
||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
Line 71: | Line 102: | ||
|- |
|- |
||
! bgcolor="#d0e7ff" align="center" |Al<sub>2</sub>O<sub>3</sub> |
! bgcolor="#d0e7ff" align="center" |Al<sub>2</sub>O<sub>3</sub> |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" | |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 2 .28Custom.29|R2]] |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |[[Sputtering Recipes| |
| bgcolor="#eeffff" |[[Sputtering Recipes|R3]] |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" |[[Sputtering Recipes|R3]] |
||
| bgcolor="#eeffff" |[[Sputtering Recipes|R1]] |
|||
| bgcolor="#eeffff" |[[Sputtering Recipes#Si3N4 deposition .28IBD.29|R5]] |
|||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |[https://wiki.nanotech.ucsb.edu/w/index.php?title=Sputtering_Recipes#Al2O3_deposition_.28IBD.29 R] |
|||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |[[Atomic Layer Deposition Recipes#Al2O3 deposition .28ALD CHAMBER 3.29|R4]] |
|||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
|- |
|||
| bgcolor="#eeffff" |{{rl|Atomic Layer Deposition Recipes|Al2O3 deposition (ALD CHAMBER 3)}} |
|||
!As |
|||
| bgcolor="#eeffff" |<br> |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|- |
|||
!AuPd |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|[[Thermal Evaporation Recipes#Thermal Evaporator 1|R1]] |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|- |
|||
!AuZn |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|[[Thermal Evaporation Recipes#Thermal Evaporator 1|R1]] |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|- |
|||
!AuSn |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|[[Thermal Evaporation Recipes#Thermal Evaporator 1|R1]] |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|- |
|||
!AuGe |
|||
|[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R1]] |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|- |
|- |
||
! bgcolor="#d0e7ff" align="center" |AlN |
! bgcolor="#d0e7ff" align="center" |AlN |
||
Line 92: | Line 208: | ||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
|[[Sputtering Recipes| |
|[[Sputtering Recipes|R1]] |
||
|[[Sputtering Recipes| |
|[[Sputtering Recipes|R1]] |
||
|<br> |
|<br> |
||
|R1 |
|||
|[[Sputtering_Recipes#Ion_Beam_Deposition_.28Veeco_NEXUS.29|A]] |
|||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
Line 101: | Line 217: | ||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
| |
|[[Atomic Layer Deposition Recipes#AlN deposition .28ALD CHAMBER 3.29|R4]] |
||
|<br> |
|<br> |
||
|- |
|- |
||
! bgcolor="#d0e7ff" align="center" |Au |
! bgcolor="#d0e7ff" align="center" |Au |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R2]] |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 3 .28Temescal.29|R2]] |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 4 .28CHA.29|R2]] |
||
| bgcolor="#eeffff" |[[Sputtering Recipes| |
| bgcolor="#eeffff" |[[Sputtering Recipes|R1]] |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" |R3 |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |[[Thermal Evaporation Recipes| |
| bgcolor="#eeffff" |[[Thermal Evaporation Recipes#Thermal Evaporator 1|R3]] |
||
| bgcolor="#eeffff" |[[Thermal Evaporation Recipes| |
| bgcolor="#eeffff" |[[Thermal Evaporation Recipes#Thermal Evaporator 2|R2]] |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
Line 131: | Line 247: | ||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
| |
|||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
Line 136: | Line 253: | ||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
|- |
|||
|<br> |
|||
!Be |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|- |
|- |
||
! bgcolor="#d0e7ff" align="center" |C |
! bgcolor="#d0e7ff" align="center" |C |
||
| bgcolor="#eeffff" align="center" | |
| bgcolor="#eeffff" align="center" |[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R3]] |
||
| bgcolor="#eeffff" align="center" | |
| bgcolor="#eeffff" align="center" | |
||
| bgcolor="#eeffff" align="center" | |
| bgcolor="#eeffff" align="center" | |
||
Line 154: | Line 287: | ||
| bgcolor="#eeffff" align="center" | |
| bgcolor="#eeffff" align="center" | |
||
| bgcolor="#eeffff" align="center" | |
| bgcolor="#eeffff" align="center" | |
||
|- |
|||
!Cd |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|- |
|||
!CdS |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|- |
|||
!CdTe |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|- |
|||
!CaF2 |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|[[Thermal Evaporation Recipes#Thermal Evaporator 2|R2]] |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|- |
|- |
||
! bgcolor="#d0e7ff" align="center" |CeO<sub>2</sub> |
! bgcolor="#d0e7ff" align="center" |CeO<sub>2</sub> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 2 .28Custom.29|R3]] |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
Line 173: | Line 374: | ||
|- |
|- |
||
! bgcolor="#d0e7ff" align="center" |Co |
! bgcolor="#d0e7ff" align="center" |Co |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R2]] |
||
| bgcolor="#eeffff" |<br> |
|||
| bgcolor="#eeffff" |<br> |
|||
| bgcolor="#eeffff" |{{Al/E4}} |
|||
| bgcolor="#eeffff" |[[Sputtering Recipes|R]] |
|||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 4 .28CHA.29|R2]] |
|||
| bgcolor="#eeffff" |[[Sputtering Recipes|R3]] |
|||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |[[Thermal Evaporation Recipes#Thermal Evaporator 1|R1]] |
|||
| bgcolor="#eeffff" |[[Thermal Evaporation Recipes#Thermal Evaporator 2|R1]] |
|||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
Line 190: | Line 391: | ||
|- |
|- |
||
! bgcolor="#d0e7ff" align="center" |Cr |
! bgcolor="#d0e7ff" align="center" |Cr |
||
|[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R1]] |
|||
|{{Al/E1}} |
|||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
|[[E-Beam Evaporation Recipes#E-Beam 4 .28CHA.29|R2]] |
|||
|{{Al/E4}} |
|||
|[https://wiki.nanotech.ucsb.edu/w/index.php?title=Sputtering_Recipes#Sputter_3_.28AJA_ATC_2000-F.29 |
|[https://wiki.nanotech.ucsb.edu/w/index.php?title=Sputtering_Recipes#Sputter_3_.28AJA_ATC_2000-F.29 R3] |
||
|<br> |
|<br> |
||
|{{Rl|Sputtering_Recipes|Sputter_5_.28AJA_ATC_2200-V.29|R3}} |
|||
|<br> |
|<br> |
||
|[[Thermal Evaporation Recipes#Thermal Evaporator 1|R3]] |
|||
|<br> |
|||
|[[Thermal Evaporation Recipes| |
|[[Thermal Evaporation Recipes#Thermal Evaporator 2|R2]] |
||
|[[Thermal Evaporation Recipes|A]] |
|||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
Line 207: | Line 408: | ||
|- |
|- |
||
! bgcolor="#d0e7ff" align="center" |Cu |
! bgcolor="#d0e7ff" align="center" |Cu |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R1]] |
||
| bgcolor="#eeffff" |<br> |
|||
| bgcolor="#eeffff" |<br> |
|||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |{{rl|Sputtering Recipes|Sputter 3 (AJA ATC 2000-F)}} |
|||
| bgcolor="#eeffff" |[[Sputtering Recipes|A]] |
|||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |[[Sputtering Recipes|R3]] |
|||
| bgcolor="#eeffff" |[[Sputtering Recipes|R2]] |
|||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |[[Thermal Evaporation Recipes#Thermal Evaporator 1|R2]] |
|||
| bgcolor="#eeffff" |[[Thermal Evaporation Recipes#Thermal Evaporator 2|R1]] |
|||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
Line 224: | Line 425: | ||
|- |
|- |
||
! bgcolor="#d0e7ff" align="center" |Fe |
! bgcolor="#d0e7ff" align="center" |Fe |
||
|[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R2]] |
|||
|{{Al/E1}} |
|||
|<br> |
|||
|<br> |
|||
|{{Al/E4}} |
|||
|[[Sputtering Recipes|R]] |
|||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
|[[E-Beam Evaporation Recipes#E-Beam 4 .28CHA.29|R2]] |
|||
|[[Sputtering Recipes|R3]] |
|||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
|[[Thermal Evaporation Recipes#Thermal Evaporator 1|R1]] |
|||
|[[Thermal Evaporation Recipes#Thermal Evaporator 2|R1]] |
|||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
Line 239: | Line 440: | ||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
|- |
|||
!Ga |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|- |
|||
!GaAs |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|- |
|- |
||
! bgcolor="#d0e7ff" align="center" |Ge |
! bgcolor="#d0e7ff" align="center" |Ge |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R2]] |
||
| bgcolor="#eeffff" |<br> |
|||
| bgcolor="#eeffff" |{{Al/E3}} |
|||
| bgcolor="#eeffff" |{{Al/E4}} |
|||
| bgcolor="#eeffff" |[[Sputtering Recipes|A]] |
|||
| bgcolor="#eeffff" |[[Sputtering Recipes|A]] |
|||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 3 .28Temescal.29|R2]] |
|||
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 4 .28CHA.29|R2]] |
|||
| bgcolor="#eeffff" |[[Sputtering Recipes|R1]] |
|||
| bgcolor="#eeffff" |[[Sputtering Recipes|R1]] |
|||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" | |
|||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
Line 259: | Line 494: | ||
! bgcolor="#d0e7ff" align="center" |GeO<sub>2</sub> |
! bgcolor="#d0e7ff" align="center" |GeO<sub>2</sub> |
||
| |
| |
||
|[[E-Beam Evaporation Recipes#E-Beam 2 .28Custom.29|R2]] |
|||
|{{Al/E2}} |
|||
| |
| |
||
| |
| |
||
Line 275: | Line 510: | ||
|- |
|- |
||
! bgcolor="#d0e7ff" align="center" |Gd |
! bgcolor="#d0e7ff" align="center" |Gd |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R2]] |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 4 .28CHA.29|R1]] |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
Line 292: | Line 527: | ||
|- |
|- |
||
! bgcolor="#d0e7ff" align="center" |Hf |
! bgcolor="#d0e7ff" align="center" |Hf |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R1]] |
||
| bgcolor="#eeffff" |<br> |
|||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br>[[E-Beam Evaporation Recipes#E-Beam 4 .28CHA.29|R1]] |
|||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
Line 313: | Line 548: | ||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
|[[Sputtering Recipes| |
|[[Sputtering Recipes|R1]] |
||
|[[Sputtering Recipes| |
|[[Sputtering Recipes|R1]] |
||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
Line 322: | Line 557: | ||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
| |
|[[Atomic Layer Deposition Recipes#AlN deposition .28ALD CHAMBER 3.29|R4]] |
||
|<br> |
|<br> |
||
|- |
|||
!Hg |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|- |
|- |
||
! bgcolor="#d0e7ff" align="center" |In |
! bgcolor="#d0e7ff" align="center" |In |
||
Line 335: | Line 587: | ||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |[[Thermal Evaporation Recipes| |
| bgcolor="#eeffff" |[[Thermal Evaporation Recipes#Thermal Evaporator 2|R3]] |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
Line 341: | Line 593: | ||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
|- |
|||
!InSb |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|- |
|- |
||
! bgcolor="#d0e7ff" align="center" |Ir |
! bgcolor="#d0e7ff" align="center" |Ir |
||
|[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R1]] |
|||
|{{Al/E1}} |
|||
|<br> |
|||
|<br> |
|||
|<br> |
|||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
|[[E-Beam Evaporation Recipes#E-Beam 4 .28CHA.29|R1]] |
|||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
| |
|||
| |
|||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
Line 361: | Line 630: | ||
! bgcolor="#d0e7ff" align="center" |ITO |
! bgcolor="#d0e7ff" align="center" |ITO |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 2 .28Custom.29|R3]] |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |[[Sputtering Recipes| |
| bgcolor="#eeffff" |[[Sputtering Recipes|R1]] |
||
| bgcolor="#eeffff" |[[Sputtering Recipes| |
| bgcolor="#eeffff" |[[Sputtering Recipes|R1]] |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" |R1 |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
Line 376: | Line 645: | ||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
|- |
|- |
||
!KCl |
|||
! bgcolor="#d0e7ff" align="center" |MgF2 |
|||
| |
|||
| |
|||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
|[[Sputtering Recipes|A]] |
|||
|[[Sputtering Recipes|A]] |
|||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|- |
|||
!LiF |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|- |
|||
!Mg |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|[[Thermal Evaporation Recipes#Thermal Evaporator 1|R1]] |
|||
|[[Thermal Evaporation Recipes#Thermal Evaporator 2|R1]] |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|- |
|||
! bgcolor="#d0e7ff" align="center" |MgF2 |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|[[Sputtering Recipes|R1]] |
|||
|[[Sputtering Recipes|R1]] |
|||
| |
|||
| |
|||
| |
|||
|[[Thermal Evaporation Recipes#Thermal Evaporator 2|R1]] |
|||
| |
| |
||
| |
| |
||
Line 395: | Line 715: | ||
! bgcolor="#d0e7ff" align="center" |MgO |
! bgcolor="#d0e7ff" align="center" |MgO |
||
| |
| |
||
|[[E-Beam Evaporation Recipes#E-Beam 2 .28Custom.29|R2]] |
|||
|{{Al/E2}} |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|- |
|||
!Mn |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|- |
|||
!MnS |
|||
| |
|||
| |
|||
| |
| |
||
| |
| |
||
Line 411: | Line 765: | ||
|- |
|- |
||
! bgcolor="#d0e7ff" align="center" |Mo |
! bgcolor="#d0e7ff" align="center" |Mo |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R2]] |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |[[Sputtering Recipes| |
| bgcolor="#eeffff" |[[Sputtering Recipes|R3]] |
||
| bgcolor="#eeffff" |[[Sputtering Recipes| |
| bgcolor="#eeffff" |[[Sputtering Recipes|R1]] |
||
| bgcolor="#eeffff" |<br> |
|||
| bgcolor="#eeffff" |<br> |
|||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" | |
|||
| bgcolor="#eeffff" | |
|||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
Line 426: | Line 780: | ||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
|- |
|||
!Na |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|- |
|||
!NaCl |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|- |
|- |
||
! bgcolor="#d0e7ff" align="center" |Nb |
! bgcolor="#d0e7ff" align="center" |Nb |
||
|[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R2]] |
|||
|{{Al/E1}} |
|||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
|[[Sputtering Recipes| |
|[[Sputtering Recipes|R3]] |
||
|<br> |
|||
|<br> |
|||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
| |
|||
| |
|||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
Line 443: | Line 831: | ||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
|- |
|||
!NbO5 |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|- |
|- |
||
! bgcolor="#d0e7ff" align="center" |Nd |
! bgcolor="#d0e7ff" align="center" |Nd |
||
Line 450: | Line 855: | ||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
|[[Sputtering Recipes| |
|[[Sputtering Recipes|R1]] |
||
|<br> |
|||
|<br> |
|||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
| |
|||
| |
|||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
Line 462: | Line 867: | ||
|- |
|- |
||
! bgcolor="#d0e7ff" align="center" |Ni |
! bgcolor="#d0e7ff" align="center" |Ni |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R2]] |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 3 .28Temescal.29|R2]] |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 4 .28CHA.29|R2]] |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" |[[Sputtering Recipes|R3]] |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |[[Thermal Evaporation Recipes| |
| bgcolor="#eeffff" |[[Thermal Evaporation Recipes#Thermal Evaporator 1|R3]] |
||
| bgcolor="#eeffff" |[[Thermal Evaporation Recipes| |
| bgcolor="#eeffff" |[[Thermal Evaporation Recipes#Thermal Evaporator 2|R2]] |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
Line 479: | Line 884: | ||
|- |
|- |
||
! bgcolor="#d0e7ff" align="center" |NiCr |
! bgcolor="#d0e7ff" align="center" |NiCr |
||
|[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R2]] |
|||
|{{Al/E1}} |
|||
| |
| |
||
| |
| |
||
|[[E-Beam Evaporation Recipes#E-Beam 4 .28CHA.29|R2]] |
|||
|{{Al/E4}} |
|||
| |
|||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
|[[Thermal Evaporation Recipes#Thermal Evaporator 1|R3]] |
|||
| |
| |
||
| |
| |
||
Line 496: | Line 901: | ||
|- |
|- |
||
! bgcolor="#d0e7ff" align="center" |NiFe |
! bgcolor="#d0e7ff" align="center" |NiFe |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R1]] |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" | |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" | |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 4 .28CHA.29|R2]] |
||
| bgcolor="#eeffff" |[[Sputtering Recipes| |
| bgcolor="#eeffff" |[[Sputtering Recipes|R1]] |
||
| bgcolor="#eeffff" | |
|||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" | |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" | |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" | |
||
| bgcolor="#eeffff" |[[Thermal Evaporation Recipes#Thermal Evaporator 1|R3]] |
|||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" | |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" | |
||
Line 511: | Line 916: | ||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" | |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" | |
||
|- |
|||
!Pb |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|- |
|||
!PbS |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|- |
|- |
||
! bgcolor="#d0e7ff" align="center" |Pd |
! bgcolor="#d0e7ff" align="center" |Pd |
||
|[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R2]] |
|||
|{{Al/E1}} |
|||
|<br> |
|<br> |
||
|[[E-Beam Evaporation Recipes#E-Beam 3 .28Temescal.29|R2]] |
|||
|{{Al/E3}} |
|||
|[[E-Beam Evaporation Recipes#E-Beam 4 .28CHA.29|R2]] |
|||
|{{Al/E4}} |
|||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
|[[Thermal Evaporation Recipes| |
|[[Thermal Evaporation Recipes#Thermal Evaporator 1|R3]] |
||
|[[Thermal Evaporation Recipes| |
|[[Thermal Evaporation Recipes#Thermal Evaporator 2|R1]] |
||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
Line 530: | Line 969: | ||
|- |
|- |
||
! bgcolor="#d0e7ff" align="center" |Pt |
! bgcolor="#d0e7ff" align="center" |Pt |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R2]] |
||
| bgcolor="#eeffff" |<br> |
|||
| bgcolor="#eeffff" |{{Al/E3}} |
|||
| bgcolor="#eeffff" |{{Al/E4}} |
|||
| bgcolor="#eeffff" |[[Sputtering Recipes|A]] |
|||
| bgcolor="#eeffff" |{{rl|Sputtering Recipes|Sputter 4 (AJA ATC 2200-V)}} |
|||
| bcolor="EEFFFF" |{{rl|Sputtering Recipes|Sputter 5 (AJA ATC 2200-V)}} |
|||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 3 .28Temescal.29|R2]] |
|||
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 4 .28CHA.29|R2]] |
|||
| bgcolor="#eeffff" |[[Sputtering Recipes|R3]] |
|||
| bgcolor="#eeffff" |[[Sputtering Recipes|R3]] |
|||
| bcolor="EEFFFF" |[[Sputtering Recipes|R3]] |
|||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" | |
|||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" |[[Atomic Layer Deposition Recipes#Pt deposition .28ALD CHAMBER 1.29|R4]] |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
|- |
|- |
||
! bgcolor="#d0e7ff" align="center" |Ru |
! bgcolor="#d0e7ff" align="center" |Ru |
||
|[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R2]] |
|||
|{{Al/E1}} |
|||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
|[[E-Beam Evaporation Recipes#E-Beam 4 .28CHA.29|R2]] |
|||
|{{Al/E4}} |
|||
|<br> |
|<br> |
||
|[[Sputtering Recipes#Ru Deposition .28Sputter 4.29| |
|[[Sputtering Recipes#Ru Deposition .28Sputter 4.29|R3]] |
||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
Line 560: | Line 999: | ||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
| |
|[[Atomic Layer Deposition Recipes#Pt deposition .28ALD CHAMBER 1.29|R4]] |
||
|<br> |
|<br> |
||
|- |
|||
!Sb |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|- |
|||
!Se |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|- |
|- |
||
! bgcolor="#d0e7ff" align="center" |Si |
! bgcolor="#d0e7ff" align="center" |Si |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 2 .28Custom.29|R2]] |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |[[Sputtering Recipes| |
| bgcolor="#eeffff" |[[Sputtering Recipes|R3]] |
||
| bgcolor="#eeffff" |[[Sputtering Recipes| |
| bgcolor="#eeffff" |[[Sputtering Recipes|R1]] |
||
| bgcolor="#eeffff" |<br> |
|||
| bgcolor="#eeffff" |<br>[[Sputtering_Recipes#Ion_Beam_Deposition_.28Veeco_NEXUS.29|A]] |
|||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |R1 |
|||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" | |
|||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |[https://wiki.nanotech.ucsb.edu/w/index.php?title=PECVD_Recipes#Amorphous-Si_deposition_.28PECVD_.232.29 R3] |
| bgcolor="#eeffff" |[https://wiki.nanotech.ucsb.edu/w/index.php?title=PECVD_Recipes#Amorphous-Si_deposition_.28PECVD_.232.29 R3] |
||
Line 585: | Line 1,058: | ||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
| |
|[[Sputtering Recipes|R3]] |
||
|[[Sputtering Recipes| |
|[[Sputtering Recipes|R1]] |
||
|<br> |
|<br> |
||
|[[ |
|[[Sputtering Recipes#Si3N4 deposition .28IBD.29|R6]] |
||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
| |
|[[PECVD Recipes#SiN deposition .28PECVD .231.29|R6]] |
||
|[[PECVD Recipes#SiN deposition .28PECVD .232.29|R6]] |
|[[PECVD Recipes#SiN deposition .28PECVD .232.29|R6]] |
||
| |
|[[PECVD Recipes#ICP-PECVD .28Unaxis VLR.29|R6]] |
||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
Line 608: | Line 1,081: | ||
| |
| |
||
| |
| |
||
| |
|[[PECVD Recipes#Low Stress Si3N4 .28PECVD.231.29|R4]] |
||
|[[PECVD Recipes#Low-Stress SiN deposition .28PECVD .232.29|R6]] |
|[[PECVD Recipes#Low-Stress SiN deposition .28PECVD .232.29|R6]] |
||
| |
|[[PECVD Recipes#ICP-PECVD .28Unaxis VLR.29|R6]] |
||
| |
| |
||
| |
| |
||
|- |
|- |
||
! bgcolor="#d0e7ff" align="center" |SiO<sub>2</sub> |
! bgcolor="#d0e7ff" align="center" |SiO<sub>2</sub> |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R2]] |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 2 .28Custom.29|R2]] |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" |[[Sputtering Recipes|R3]] |
||
| bgcolor="#eeffff" |[[Sputtering Recipes| |
| bgcolor="#eeffff" |[[Sputtering Recipes|R1]] |
||
| bgcolor="#eeffff" |[[Sputtering Recipes| |
| bgcolor="#eeffff" |[[Sputtering Recipes|R2]] |
||
| bgcolor="#eeffff" |[[Sputtering_Recipes#SiO2_deposition_.28IBD.29| |
| bgcolor="#eeffff" |[[Sputtering_Recipes#SiO2_deposition_.28IBD.29|R6]] |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" | |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" |[[PECVD Recipes#SiO2 deposition .28PECVD .231.29|R6]] |
||
| bgcolor="#eeffff" |[[PECVD Recipes#SiO2 deposition .28PECVD .232.29|R6]] |
| bgcolor="#eeffff" |[[PECVD Recipes#SiO2 deposition .28PECVD .232.29|R6]] |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" |[[PECVD Recipes#ICP-PECVD .28Unaxis VLR.29|R6]] |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" |[[Atomic Layer Deposition Recipes#Pt deposition .28ALD CHAMBER 1.29|R4]] |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
|- |
|||
!SiO<sub>x</sub> |
|||
| |
|||
|[[E-Beam Evaporation Recipes#E-Beam 2 .28Custom.29|R1]] |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|- |
|||
!SiO |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|[[Thermal Evaporation Recipes#Thermal Evaporator 1|R1]] |
|||
|[[Thermal Evaporation Recipes#Thermal Evaporator 2|R1]] |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|- |
|- |
||
! bgcolor="#d0e7ff" align="center" |SiO<sub>x</sub>N<sub>y</sub> |
! bgcolor="#d0e7ff" align="center" |SiO<sub>x</sub>N<sub>y</sub> |
||
Line 639: | Line 1,146: | ||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
|[[Sputtering Recipes#Si3N4 deposition .28IBD.29|R3]] |
|||
|[https://wiki.nanotech.ucsb.edu/w/index.php?title=Sputtering_Recipes#SiOxNy_deposition_.28IBD.29 R] |
|||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
|[[PECVD Recipes#SiO2 deposition .28PECVD .231.29|R4]] |
|||
|[[PECVD_Recipes#PECVD_1_.28PlasmaTherm_790.29|R]] |
|||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
Line 658: | Line 1,165: | ||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |[[Thermal Evaporation Recipes| |
| bgcolor="#eeffff" |[[Thermal Evaporation Recipes#Thermal Evaporator 2|R2]] |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
Line 667: | Line 1,174: | ||
! bgcolor="#d0e7ff" align="center" |SrF<sub>2</sub> |
! bgcolor="#d0e7ff" align="center" |SrF<sub>2</sub> |
||
|<br> |
|<br> |
||
|[[E-Beam Evaporation Recipes#E-Beam 2 .28Custom.29|R2]] |
|||
|{{Al/E2}} |
|||
|<br> |
|||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
Line 675: | Line 1,181: | ||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
|[[Thermal Evaporation Recipes#Thermal Evaporator 1|R1]] |
|||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
Line 683: | Line 1,190: | ||
|- |
|- |
||
! bgcolor="#d0e7ff" align="center" |Ta |
! bgcolor="#d0e7ff" align="center" |Ta |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R1]] |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" |[[Sputtering Recipes|R3]] |
||
| bgcolor="#eeffff" |[[Sputtering Recipes| |
| bgcolor="#eeffff" |[[Sputtering Recipes|R1]] |
||
| bgcolor="#eeffff" |<br> |
|||
| bgcolor="#eeffff" |<br>[[Sputtering_Recipes#Ion_Beam_Deposition_.28Veeco_NEXUS.29|A]] |
|||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |R1 |
|||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" | |
|||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
Line 701: | Line 1,208: | ||
! bgcolor="#d0e7ff" align="center" |Ta<sub>2</sub>O<sub>5</sub> |
! bgcolor="#d0e7ff" align="center" |Ta<sub>2</sub>O<sub>5</sub> |
||
|<br> |
|<br> |
||
|[[E-Beam Evaporation Recipes#E-Beam 2 .28Custom.29|R1]] |
|||
|<br> |
|<br> |
||
|[[E-Beam Evaporation Recipes#E-Beam 4 .28CHA.29|R1]] |
|||
|<br> |
|<br> |
||
|{{Al/E2}} |
|||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
|[[Sputtering Recipes#Si3N4 deposition .28IBD.29|R6]] |
|||
|<br> |
|<br> |
||
| |
|||
|[[Sputtering_Recipes#Ta2O5_deposition_.28IBD.29|R]] |
|||
|<br> |
|||
|<br> |
|||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
Line 717: | Line 1,224: | ||
|- |
|- |
||
! bgcolor="#d0e7ff" align="center" |Ti |
! bgcolor="#d0e7ff" align="center" |Ti |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R2]] |
||
| bgcolor="#eeffff" |<br> |
|||
| bgcolor="#eeffff" |{{Al/E3}} |
|||
| bgcolor="#eeffff" |{{Al/E4}} |
|||
| bgcolor="#eeffff" |{{rl|Sputtering Recipes|Sputter 3 (AJA ATC 2000-F)}} |
|||
| bgcolor="#eeffff" |{{rl|Sputtering Recipes|Ti-Au Deposition (Sputter 4)}} |
|||
| bgcolor="#eeffff" |{{rl|Sputtering Recipes|Sputter 5 (AJA ATC 2200-V)}} |
|||
| bgcolor="#eeffff" |<br>[[Sputtering_Recipes#Ion_Beam_Deposition_.28Veeco_NEXUS.29|A]] |
|||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 3 .28Temescal.29|R2]] |
|||
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 4 .28CHA.29|R2]] |
|||
| bgcolor="#eeffff" |[[Sputtering Recipes|R3]] |
|||
| bgcolor="#eeffff" |[[Sputtering Recipes|R3]] |
|||
| bgcolor="#eeffff" |[[Sputtering Recipes|R3]] |
|||
| bgcolor="#eeffff" |R1 |
|||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" | |
|||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
Line 739: | Line 1,246: | ||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
|[https://wiki.nanotech.ucsb.edu/w/index.php?title=Sputtering_Recipes#Sputter_4_.28AJA_ATC_2200-V.29 |
|[https://wiki.nanotech.ucsb.edu/w/index.php?title=Sputtering_Recipes#Sputter_4_.28AJA_ATC_2200-V.29 R3] |
||
|<br> |
|<br> |
||
|R1 |
|||
|[[Sputtering_Recipes#Ion_Beam_Deposition_.28Veeco_NEXUS.29|A]] |
|||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
Line 747: | Line 1,254: | ||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
| |
|[[Atomic Layer Deposition Recipes#Pt deposition .28ALD CHAMBER 1.29|R4]] |
||
|<br> |
|<br> |
||
|- |
|- |
||
! bgcolor="#d0e7ff" align="center" |TiW |
! bgcolor="#d0e7ff" align="center" |TiW |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R1]] |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |[[Sputtering Recipes| |
| bgcolor="#eeffff" |[[Sputtering Recipes|R2]] |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" |[[Sputtering Recipes|R3]] |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
Line 766: | Line 1,273: | ||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
|- |
|||
!TiO |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|- |
|- |
||
! bgcolor="#d0e7ff" align="center" |TiO<sub>2</sub> |
! bgcolor="#d0e7ff" align="center" |TiO<sub>2</sub> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 2 .28Custom.29|R2]] |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |[[Sputtering Recipes| |
| bgcolor="#eeffff" |[[Sputtering Recipes|R1]] |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" |[[Sputtering Recipes|R3]] |
||
| bgcolor="#eeffff" |<br> |
|||
| bgcolor="#eeffff" |[[Sputtering_Recipes#TiO2_deposition_.28IBD.29|R]] |
|||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |[[Sputtering Recipes#Si3N4 deposition .28IBD.29|R5]] |
|||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" | |
|||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" |[[Atomic Layer Deposition Recipes#Pt deposition .28ALD CHAMBER 1.29|R4]] |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
|- |
|- |
||
Line 789: | Line 1,313: | ||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
|[[Sputtering Recipes| |
|[[Sputtering Recipes|R1]] |
||
|[[Sputtering Recipes| |
|[[Sputtering Recipes|R1]] |
||
|<br> |
|||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
| |
|||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
Line 802: | Line 1,326: | ||
|- |
|- |
||
! bgcolor="#d0e7ff" align="center" |W |
! bgcolor="#d0e7ff" align="center" |W |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R2]] |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |[[Sputtering Recipes| |
| bgcolor="#eeffff" |[[Sputtering Recipes|R2]] |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" |[[Sputtering Recipes|R3]] |
||
| bgcolor="#eeffff" |<br> |
|||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" | |
|||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
Line 817: | Line 1,341: | ||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
|- |
|||
!WC |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|- |
|- |
||
! bgcolor="#d0e7ff" align="center" |Zn |
! bgcolor="#d0e7ff" align="center" |Zn |
||
Line 827: | Line 1,368: | ||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
|[[Thermal Evaporation Recipes| |
|[[Thermal Evaporation Recipes#Thermal Evaporator 1|R3]] |
||
|[[Thermal Evaporation Recipes| |
|[[Thermal Evaporation Recipes#Thermal Evaporator 2|R2]] |
||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
Line 844: | Line 1,385: | ||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" | |
|||
| bgcolor="#eeffff" | |
|||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |[[Atomic Layer Deposition Recipes#Pt deposition .28ALD CHAMBER 1.29|R3]] |
|||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
|- |
|||
| bgcolor="#eeffff" |<br> |
|||
!ZnS |
|||
| bgcolor="#eeffff" |{{rl|Atomic Layer Deposition Recipes|ZnO:Al deposition (ALD CHAMBER 1)}} |
|||
| |
|||
| bgcolor="#eeffff" |<br> |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|- |
|- |
||
! bgcolor="#d0e7ff" align="center" |Zr |
! bgcolor="#d0e7ff" align="center" |Zr |
||
|[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R2]] |
|||
|{{Al/E1}} |
|||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
|[[E-Beam Evaporation Recipes#E-Beam 4 .28CHA.29|R2]] |
|||
|{{Al/E4}} |
|||
|[[Sputtering Recipes| |
|[[Sputtering Recipes|R1]] |
||
|[[Sputtering Recipes| |
|[[Sputtering Recipes|R1]] |
||
|<br> |
|||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
|[[Thermal Evaporation Recipes#Thermal Evaporator 2|R1]] |
|||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
Line 879: | Line 1,437: | ||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" | |
|||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" | |
| bgcolor="#eeffff" |[[Atomic Layer Deposition Recipes#Pt deposition .28ALD CHAMBER 1.29|R4]] |
||
| bgcolor="#eeffff" |{{rl|Atomic Layer Deposition Recipes|ZrO2 deposition (ALD CHAMBER 3)}} |
|||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
|- |
|- |
||
Line 904: | Line 1,462: | ||
|} |
|} |
||
===Process Ranking Table=== |
|||
Processes in the table above are ranked by their "''Process Maturity Level''" as follows: |
|||
{| class="wikitable" |
|||
|'''Process Level''' |
|||
| colspan="11" |'''Description of Process Level Ranking''' |
|||
|- |
|||
|A |
|||
| colspan="11" |Process '''A'''llowed and materials available but never done |
|||
|- |
|||
|R1 |
|||
| colspan="11" |Process has been ran at least once |
|||
|- |
|||
|R2 |
|||
| colspan="11" |Process has been ran and/or procedure is documented or/and data available |
|||
|- |
|||
|R3 |
|||
| colspan="11" |Process has been ran, procedure is documented, and data is available |
|||
|- |
|||
|R4 |
|||
| colspan="11" |Process has a documented procedure with regular (≥4x per year) data '''or''' lookahead/in-Situ control available |
|||
|- |
|||
|R5 |
|||
| colspan="11" |Process has a documented procedure with regular (≥4x per year) data '''and''' lookahead/in-Situ control available |
|||
|- |
|||
|R6 |
|||
| colspan="11" |Process has a documented procedure, regular ( ≥4x per year) data, and control charts/limits available |
|||
|} |
|||
[[Category:Processing]] |
[[Category:Processing]] |
Latest revision as of 21:57, 7 November 2024
Process Control Data
See linked page for process control data (calibration data over time, such as dep. rate, refractive index, stress etc.) over time, for a selection of highly used tools/films.
Deposition Tools/Materials Table
The Key/Legend for this table's A...R6
values is at the bottom of the page.
Process Ranking Table
Processes in the table above are ranked by their "Process Maturity Level" as follows:
Process Level | Description of Process Level Ranking | ||||||||||
A | Process Allowed and materials available but never done | ||||||||||
R1 | Process has been ran at least once | ||||||||||
R2 | Process has been ran and/or procedure is documented or/and data available | ||||||||||
R3 | Process has been ran, procedure is documented, and data is available | ||||||||||
R4 | Process has a documented procedure with regular (≥4x per year) data or lookahead/in-Situ control available | ||||||||||
R5 | Process has a documented procedure with regular (≥4x per year) data and lookahead/in-Situ control available | ||||||||||
R6 | Process has a documented procedure, regular ( ≥4x per year) data, and control charts/limits available |