Vacuum Deposition Recipes: Difference between revisions

From UCSB Nanofab Wiki
Jump to navigation Jump to search
No edit summary
m (add Sputter5 ITO and Ni currently on system)
 
(128 intermediate revisions by 8 users not shown)
Line 1: Line 1:
===[[Process Group - Process Control Data#Deposition .28Process Control Data.29|<u>Process Control Data</u>]]===
{{Recipe Table Explanation}}
<small>''See [[Process Group - Process Control Data#Deposition .28Process Control Data.29|linked page]] for process control data (calibration data over time, such as dep. rate, refractive index, stress etc.) over time, for a selection of highly used tools/films.''</small>
{| border="1" class="wikitable" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center;"

|- bgcolor="#D0E7FF"
===Deposition Tools/Materials Table===
! width="1675" height="45" colspan="18" | <div style="font-size: 150%;">Vacuum Deposition Recipes</div>
''The Key/Legend for this table's <code>A...R6</code> values is at the [[Vacuum Deposition Recipes#Process Ranking Table|<u>bottom of the page</u>]].''
|- bgcolor="#D0E7FF"
{| class="wikitable" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center;" border="1"
| <!-- INTENTIONALLY LEFT BLANK --> <br>
|- bgcolor="#d0e7ff"
! bgcolor="#D0E7FF" align="center" colspan="4" | '''[[E-Beam Evaporation Recipes|E-Beam Evaporation]]'''
! colspan="16" width="1675" height="45" |<div style="font-size: 150%;">Vacuum Deposition Recipes</div>
! bgcolor="#D0E7FF" align="center" colspan="6" | '''[[Sputtering Recipes|Sputtering]]'''
|- bgcolor="#d0e7ff"
! bgcolor="#D0E7FF" align="center" colspan="2" | '''[[Thermal Evaporation Recipes|Thermal Evaporation]]'''
|<!-- INTENTIONALLY LEFT BLANK --><br>
! bgcolor="#D0E7FF" align="center" colspan="3" | '''[[PECVD Recipes|Plasma Enhanced Chemical<br>Vapor Deposition (PECVD)]]'''
! width="90" bgcolor="#D0E7FF" align="center" | '''[[Atomic Layer Deposition Recipes|Atomic Layer Deposition]]'''
! colspan="4" bgcolor="#d0e7ff" align="center" |'''[[E-Beam Evaporation Recipes|E-Beam Evaporation]]'''
! width="80" bgcolor="#D0E7FF" align="center" | '''[[Molecular Vapor Deposition Recipes|Molecular Vapor Deposition]]'''
! colspan="4" |'''[[Sputtering Recipes|Sputtering]]'''
! colspan="2" bgcolor="#d0e7ff" align="center" |'''[[Thermal Evaporation Recipes|Thermal Evaporation]]'''
! colspan="3" bgcolor="#d0e7ff" align="center" |'''[[PECVD Recipes|Plasma Enhanced Chemical<br>Vapor Deposition (PECVD)]]'''
! width="90" bgcolor="#d0e7ff" align="center" |'''[[Atomic Layer Deposition Recipes|Atomic Layer Deposition]]'''
! width="80" bgcolor="#d0e7ff" align="center" |'''[[Molecular Vapor Deposition Recipes|Molecular Vapor Deposition]]'''
|-
|-
! width="20" bgcolor="#D0E7FF" align="center" | '''Material'''
! width="20" bgcolor="#d0e7ff" align="center" |'''Material'''
| width="65" bgcolor="#DAF1FF" | [[E-Beam Evaporation Recipes#E-Beam_1_.28Sharon.29|E-Beam 1 (Sharon)]]
| width="65" bgcolor="#daf1ff" |[[E-Beam Evaporation Recipes#E-Beam_1_.28Sharon.29|E-Beam 1 (Sharon)]]
| width="65" bgcolor="#DAF1FF" | [[E-Beam Evaporation Recipes#E-Beam_2_.28Custom.29|E-Beam 2 (Custom)]]
| width="65" bgcolor="#daf1ff" |[[E-Beam Evaporation Recipes#E-Beam_2_.28Custom.29|E-Beam 2 (Custom)]]
| width="65" bgcolor="#DAF1FF" | [[E-Beam Evaporation Recipes#E-Beam_3_.28Temescal.29|E-Beam 3 (Temescal)]]
| width="65" bgcolor="#daf1ff" |[[E-Beam Evaporation Recipes#E-Beam_3_.28Temescal.29|E-Beam 3 (Temescal)]]
| width="65" bgcolor="#DAF1FF" | [[E-Beam Evaporation Recipes#E-Beam_4_.28CHA.29|E-Beam 4 (CHA)]]
| width="65" bgcolor="#daf1ff" |[[E-Beam Evaporation Recipes#E-Beam_4_.28CHA.29|E-Beam 4 (CHA)]]
| width="65" bgcolor="#DAF1FF" | [[Sputtering Recipes#Sputter_1_.28Custom.29|Sputter 1 (Custom)]]
| width="65" bgcolor="#daf1ff" |[[Sputtering_Recipes#Sputter_3_.28AJA_ATC_2000-F.29|Sputter 3<br>(AJA ATC 2000-F)]]
| width="65" bgcolor="#DAF1FF" | [[Sputtering Recipes#Sputter_2_.28SFI_Endeavor.29|Sputter 2<br>(SFI Endeavor)]]
| width="65" bgcolor="#daf1ff" |[[Sputtering_Recipes#Sputter_4_.28AJA_ATC_2200-V.29|Sputter 4<br>(AJA ATC 2200-V)]]
| width="65" bgcolor="#DAF1FF" | [[Sputtering Recipes#Sputter_3_.28ATC_2000-F.29|Sputter 3<br>(ATC 2000-F)]]
| width="65" bgcolor="#daf1ff" |[https://wiki.nanotech.ucsb.edu/w/index.php?title=Sputtering_Recipes#Sputter_5_.28AJA_ATC_2200-V.29 Sputter 5 (AJA ATC 2200-V)]
| width="65" bgcolor="#DAF1FF" | [[Sputtering Recipes#Sputter_4_.28ATC_2200-V.29|Sputter 4<br>(ATC 2200-V)]]
| width="55" bgcolor="#daf1ff" |[[Sputtering_Recipes#Ion_Beam_Deposition_.28Veeco_NEXUS.29|Ion Beam<br>Deposition (Veeco Nexus)]]
| width="65" bgcolor="#DAF1FF" | [[Sputtering Recipes#Sputter_5_.28Lesker_AXXIS.29|Sputter 5 (Lesker AXXIS)]]
| width="45" bgcolor="#daf1ff" |[[Thermal Evaporation Recipes#Thermal_Evap_1|Thermal<br>Evap 1]]
| width="55" bgcolor="#DAF1FF" | [[Ion Beam Deposition (Veeco NEXUS)|Ion Beam<br>Deposition (Tool)]]
| width="65" bgcolor="#daf1ff" |[[Thermal Evaporation Recipes#Thermal_Evap_2_.28Solder.29|Thermal Evap 2 (Solder)]]
| width="45" bgcolor="#DAF1FF" | [[Thermal Evaporation Recipes#Thermal_Evap_1|Thermal<br>Evap 1]]
| width="65" bgcolor="#daf1ff" |[[PECVD Recipes#PECVD_1_.28PlasmaTherm_790.29|PECVD 1<br>(PlasmaTherm 790)]]
| width="65" bgcolor="#DAF1FF" | [[Thermal Evaporation Recipes#Thermal_Evap_2_.28Solder.29|Thermal Evap 2 (Solder)]]
| width="65" bgcolor="#daf1ff" |[[PECVD Recipes#PECVD_2_.28Advanced_Vacuum.29|PECVD 2<br>(Advanced Vacuum)]]
| width="65" bgcolor="#DAF1FF" | [[PECVD Recipes#PECVD_1_.28PlasmaTherm_790.29|PECVD 1<br>(PlasmaTherm 790)]]
| width="65" bgcolor="#daf1ff" |[[PECVD_Recipes#ICP-PECVD_.28Unaxis_VLR.29|Unaxis VLR ICP-PECVD]]
| width="65" bgcolor="#DAF1FF" | [[PECVD Recipes#PECVD_2_.28Advanced_Vacuum.29|PECVD 2<br>(Advanced Vacuum)]]
| width="65" bgcolor="#daf1ff" |[[Atomic_Layer_Deposition_Recipes|Atomic Layer Deposition (Oxford FlexAL)]]
| width="65" bgcolor="#DAF1FF" | [[PECVD Recipes#Unaxis_VLR_ICP-PECVD|Unaxis VLR ICP-PECVD]]
| width="65" bgcolor="#daf1ff" |[[Molecular Vapor Deposition|Molecular Vapor Deposition (Tool)]]
| width="65" bgcolor="#DAF1FF" | [[Atomic Layer Deposition (Oxford FlexAL)|Atomic Layer Deposition (Tool)]]
| width="65" bgcolor="#DAF1FF" | [[Molecular Vapor Deposition|Molecular Vapor Deposition (Tool)]]
|-
|-
! bgcolor="#D0E7FF" align="center" | Ag
! bgcolor="#d0e7ff" align="center" |Ag
| bgcolor="EEFFFF" | {{Al/E1}}
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R2]]
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | {{Al/E3}}
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 3 .28Temescal.29|R2]]
| bgcolor="EEFFFF" | {{Al/E4}}
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 4 .28CHA.29|R2]]
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |[[Sputtering Recipes|R1]]
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |[[Sputtering Recipes|R1]]
| bgcolor="EEFFFF" | [[Sputtering Recipes|A]]
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | [[Sputtering Recipes|A]]
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |[[Thermal Evaporation Recipes#Thermal Evaporator 1|R1]]
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |[[Thermal Evaporation Recipes#Thermal Evaporator 2|R1]]
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | <br>
| bgcolor="EEFFFF" | <br>
|-
|-
!AgBr
! bgcolor="#D0E7FF" align="center" | Al
|
| {{Al/E1}}
|
| <br>
|
| {{Al/E3}}
|
| {{Al/E4}}
|
| <br>
|
| {{rl|Sputtering Recipes|Al deposition (Sputter 2)}}
|
| [[Sputtering Recipes|A]]
|
| [[Sputtering Recipes|R]]
|
| <br>
|
| <br>
|
| [[Thermal Evaporation Recipes|A]]
|
| [[Thermal Evaporation Recipes|A]]
|
| <br>
|
| <br>
|
| <br>
| <br>
| <br>
|-
|-
!AgCl
! bgcolor="#D0E7FF" align="center" | Al<sub>2</sub>O<sub>3</sub>
|
| bgcolor="EEFFFF" | {{Al/E1}}
|
| bgcolor="EEFFFF" | {{Al/E2}}
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | [[Sputtering Recipes|A]]
|
| bgcolor="EEFFFF" | [[Sputtering Recipes|A]]
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | [[Ion_Beam_Deposition_(Veeco_NEXUS)|A]]
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
| bgcolor="EEFFFF" | {{rl|Atomic Layer Deposition Recipes|Al2O3 deposition (ALD)}}
| bgcolor="EEFFFF" | <br>
|-
|-
! bgcolor="#D0E7FF" align="center" | AlN
! bgcolor="#d0e7ff" align="center" |Al
|[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R2]]
| <br>
| <br>
|<br>
|[[E-Beam Evaporation Recipes#E-Beam 3 .28Temescal.29|R2]]
| <br>
|[[E-Beam Evaporation Recipes#E-Beam 4 .28CHA.29|R2]]
| <br>
|[[Sputtering Recipes|R1]]
| <br>
| {{rl|Sputtering Recipes|AlN deposition (Sputter 2)}}
|[[Sputtering Recipes|R3]]
| [[Sputtering Recipes|A]]
|[[Sputtering Recipes|R1]]
|R1
| [[Sputtering Recipes|A]]
|[[Thermal Evaporation Recipes#Thermal Evaporator 1|R3]]
| <br>
|[[Thermal Evaporation Recipes#Thermal Evaporator 2|R1]]
| [[Ion_Beam_Deposition_(Veeco_NEXUS)|A]]
| <br>
|<br>
| <br>
|<br>
| <br>
|<br>
| <br>
|<br>
| <br>
|<br>
| {{rl|Atomic Layer Deposition Recipes|AlN deposition (ALD)}}
| <br>
|-
|-
! bgcolor="#D0E7FF" align="center" | Au
! bgcolor="#d0e7ff" align="center" |Al<sub>2</sub>O<sub>3</sub>
| bgcolor="EEFFFF" | {{Al/E1}}
| bgcolor="#eeffff" |
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 2 .28Custom.29|R2]]
| bgcolor="EEFFFF" | {{Al/E3}}
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | {{Al/E4}}
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |[[Sputtering Recipes|R3]]
| bgcolor="EEFFFF" | {{rl|Sputtering Recipes|Au deposition (Sputter 2)}}
| bgcolor="#eeffff" |[[Sputtering Recipes|R3]]
| bgcolor="EEFFFF" | [[Sputtering Recipes|A]]
| bgcolor="#eeffff" |[[Sputtering Recipes|R1]]
| bgcolor="EEFFFF" | {{rl|Sputtering Recipes|Ti-Au Deposition (Sputter 4)}}
| bgcolor="#eeffff" |[[Sputtering Recipes#Si3N4 deposition .28IBD.29|R5]]
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | [[Thermal Evaporation Recipes|A]]
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | [[Thermal Evaporation Recipes|A]]
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |[[Atomic Layer Deposition Recipes#Al2O3 deposition .28ALD CHAMBER 3.29|R4]]
| bgcolor="EEFFFF" | <br>
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | <br>
| bgcolor="EEFFFF" | <br>
|-
|-
!As
! bgcolor="#D0E7FF" align="center" | B
|
| <br>
|
| <br>
|
| <br>
|
| <br>
|
| <br>
|
| <br>
|
| <br>
|
| <br>
|
| <br>
|
| <br>
|
| <br>
|
| <br>
|
| <br>
|
| <br>
|
| <br>
| <br>
| <br>
|-
|-
!AuPd
! bgcolor="#D0E7FF" align="center" | Co
|
| bgcolor="EEFFFF" | {{Al/E1}}
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | {{Al/E4}}
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | [[Sputtering Recipes|R]]
|
| bgcolor="EEFFFF" | <br>
|[[Thermal Evaporation Recipes#Thermal Evaporator 1|R1]]
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
| bgcolor="EEFFFF" | <br>
| bgcolor="EEFFFF" | <br>
|-
|-
!AuZn
! bgcolor="#D0E7FF" align="center" | Cr
|
| {{Al/E1}}
|
| <br>
|
| <br>
|
| {{Al/E4}}
|
| <br>
|
| <br>
|
| [[Sputtering Recipes|R]]
|
| <br>
|[[Thermal Evaporation Recipes#Thermal Evaporator 1|R1]]
| <br>
|
| <br>
|
| [[Thermal Evaporation Recipes|A]]
|
| [[Thermal Evaporation Recipes|A]]
|
| <br>
|
| <br>
|
| <br>
| <br>
| <br>
|-
|-
!AuSn
! bgcolor="#D0E7FF" align="center" | Cu
|
| bgcolor="EEFFFF" | {{Al/E1}}
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | [[Sputtering Recipes|A]]
|
| bgcolor="EEFFFF" | [[Sputtering Recipes|A]]
|
| bgcolor="EEFFFF" | <br>
|[[Thermal Evaporation Recipes#Thermal Evaporator 1|R1]]
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
| bgcolor="EEFFFF" | <br>
| bgcolor="EEFFFF" | <br>
|-
|-
!AuGe
! bgcolor="#D0E7FF" align="center" | Fe
|[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R1]]
| {{Al/E1}}
|
| <br>
|
| <br>
|
| {{Al/E4}}
|
| <br>
|
| <br>
|
| [[Sputtering Recipes|R]]
|
| <br>
|
| <br>
|
| <br>
|
| <br>
|
| <br>
|
| <br>
|
| <br>
|
| <br>
| <br>
| <br>
|-
|-
! bgcolor="#D0E7FF" align="center" | Ge
! bgcolor="#d0e7ff" align="center" |AlN
|<br>
| bgcolor="EEFFFF" | {{Al/E1}}
|<br>
| bgcolor="EEFFFF" | <br>
|<br>
| bgcolor="EEFFFF" | {{Al/E3}}
|<br>
| bgcolor="EEFFFF" | {{Al/E4}}
|[[Sputtering Recipes|R1]]
| bgcolor="EEFFFF" | <br>
|[[Sputtering Recipes|R1]]
| bgcolor="EEFFFF" | <br>
|<br>
| bgcolor="EEFFFF" | [[Sputtering Recipes|A]]
|R1
| bgcolor="EEFFFF" | [[Sputtering Recipes|A]]
|<br>
| bgcolor="EEFFFF" | <br>
|<br>
| bgcolor="EEFFFF" | <br>
|<br>
| bgcolor="EEFFFF" | <br>
|<br>
| bgcolor="EEFFFF" | <br>
|<br>
| bgcolor="EEFFFF" | <br>
|[[Atomic Layer Deposition Recipes#AlN deposition .28ALD CHAMBER 3.29|R4]]
| bgcolor="EEFFFF" | <br>
|<br>
| bgcolor="EEFFFF" | <br>
| bgcolor="EEFFFF" | <br>
| bgcolor="EEFFFF" | <br>
|-
|-
! bgcolor="#D0E7FF" align="center" | GeO<sub>2</sub>
! bgcolor="#d0e7ff" align="center" |Au
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R2]]
|
| bgcolor="#eeffff" |<br>
| {{Al/E2}}
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 3 .28Temescal.29|R2]]
|
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 4 .28CHA.29|R2]]
|
| bgcolor="#eeffff" |[[Sputtering Recipes|R1]]
|
| bgcolor="#eeffff" |R3
|
| bgcolor="#eeffff" |<br>
|
| bgcolor="#eeffff" |<br>
|
| bgcolor="#eeffff" |[[Thermal Evaporation Recipes#Thermal Evaporator 1|R3]]
|
| bgcolor="#eeffff" |[[Thermal Evaporation Recipes#Thermal Evaporator 2|R2]]
|
| bgcolor="#eeffff" |<br>
|
| bgcolor="#eeffff" |<br>
|
| bgcolor="#eeffff" |<br>
|
| bgcolor="#eeffff" |<br>
|
| bgcolor="#eeffff" |<br>
|
|
|
|-
|-
! bgcolor="#D0E7FF" align="center" | Gd
! bgcolor="#d0e7ff" align="center" |B
|<br>
| bgcolor="EEFFFF" | {{Al/E1}}
|<br>
| bgcolor="EEFFFF" | <br>
|<br>
| bgcolor="EEFFFF" | <br>
|<br>
| bgcolor="EEFFFF" | {{Al/E4}}
|<br>
| bgcolor="EEFFFF" | <br>
|<br>
| bgcolor="EEFFFF" | <br>
|<br>
| bgcolor="EEFFFF" | <br>
|<br>
| bgcolor="EEFFFF" | <br>
|<br>
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|<br>
| bgcolor="EEFFFF" | <br>
|<br>
| bgcolor="EEFFFF" | <br>
|<br>
| bgcolor="EEFFFF" | <br>
|<br>
| bgcolor="EEFFFF" | <br>
|<br>
| bgcolor="EEFFFF" | <br>
| bgcolor="EEFFFF" | <br>
| bgcolor="EEFFFF" | <br>
|-
|-
!Be
! bgcolor="#D0E7FF" align="center" | Hf
|
| bgcolor="EEFFFF" | {{Al/E1}}
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
| bgcolor="EEFFFF" | <br>
| bgcolor="EEFFFF" | <br>
|-
|-
! bgcolor="#D0E7FF" align="center" | HfO<sub>2</sub>
! bgcolor="#d0e7ff" align="center" |C
| bgcolor="#eeffff" align="center" |[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R3]]
| <br>
| bgcolor="#eeffff" align="center" |
| <br>
| bgcolor="#eeffff" align="center" |
| <br>
| bgcolor="#eeffff" align="center" |
| <br>
| bgcolor="#eeffff" align="center" |
| <br>
| bgcolor="#eeffff" align="center" |
| <br>
| bgcolor="#eeffff" align="center" |
| [[Sputtering Recipes|A]]
| bgcolor="#eeffff" align="center" |
| [[Sputtering Recipes|A]]
| bgcolor="#eeffff" align="center" |
| <br>
| bgcolor="#eeffff" align="center" |
| <br>
| bgcolor="#eeffff" align="center" |
| <br>
| bgcolor="#eeffff" align="center" |
| <br>
| bgcolor="#eeffff" align="center" |
| <br>
| bgcolor="#eeffff" align="center" |
| <br>
| bgcolor="#eeffff" align="center" |
| <br>
| {{rl|Atomic Layer Deposition Recipes|HfO2 deposition (ALD)}}
| <br>
|-
|-
!Cd
! bgcolor="#D0E7FF" align="center" | In
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | [[Thermal Evaporation Recipes|A]]
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
| bgcolor="EEFFFF" | <br>
| bgcolor="EEFFFF" | <br>
|-
|-
!CdS
! bgcolor="#D0E7FF" align="center" | Ir
|
| {{Al/E1}}
|
| <br>
|
| <br>
|
| <br>
|
| <br>
|
| <br>
|
| <br>
|
| <br>
|
| <br>
|
| <br>
|
| <br>
|
| <br>
|
| <br>
|
| <br>
|
| <br>
| <br>
| <br>
|-
|-
!CdTe
! bgcolor="#D0E7FF" align="center" | ITO
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | {{Al/E2}}
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | [[Sputtering Recipes|A]]
|
| bgcolor="EEFFFF" | [[Sputtering Recipes|A]]
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | [[Ion_Beam_Deposition_(Veeco_NEXUS)|A]]
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
| bgcolor="EEFFFF" | <br>
| bgcolor="EEFFFF" | <br>
|-
|-
!CaF2
! bgcolor="#D0E7FF" align="center" | MgF2
|
|
|
|
|
|
|
|
|
|
|
|
|
| [[Sputtering Recipes|A]]
|
| [[Sputtering Recipes|A]]
|
|
|[[Thermal Evaporation Recipes#Thermal Evaporator 2|R2]]
|
|
|
|
|
|
|
|
|
|
|
|
|
|-
|-
! bgcolor="#D0E7FF" align="center" | MgO
! bgcolor="#d0e7ff" align="center" |CeO<sub>2</sub>
| bgcolor="#eeffff" |<br>
|
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 2 .28Custom.29|R3]]
| {{Al/E2}}
| bgcolor="#eeffff" |<br>
|
| bgcolor="#eeffff" |<br>
|
| bgcolor="#eeffff" |<br>
|
| bgcolor="#eeffff" |<br>
|
| bgcolor="#eeffff" |<br>
|
| bgcolor="#eeffff" |<br>
|
| bgcolor="#eeffff" |<br>
|
| bgcolor="#eeffff" |<br>
|
| bgcolor="#eeffff" |<br>
|
| bgcolor="#eeffff" |<br>
|
| bgcolor="#eeffff" |<br>
|
| bgcolor="#eeffff" |<br>
|
| bgcolor="#eeffff" |<br>
|
|
|
|-
|-
! bgcolor="#D0E7FF" align="center" | Mo
! bgcolor="#d0e7ff" align="center" |Co
| bgcolor="EEFFFF" | {{Al/E1}}
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R2]]
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 4 .28CHA.29|R2]]
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |[[Sputtering Recipes|R3]]
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | [[Sputtering Recipes|A]]
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | [[Sputtering Recipes|A]]
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |[[Thermal Evaporation Recipes#Thermal Evaporator 1|R1]]
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |[[Thermal Evaporation Recipes#Thermal Evaporator 2|R1]]
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | <br>
| bgcolor="EEFFFF" | <br>
|-
|-
! bgcolor="#D0E7FF" align="center" | Nb
! bgcolor="#d0e7ff" align="center" |Cr
|[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R1]]
| {{Al/E1}}
| <br>
|<br>
| <br>
|<br>
|[[E-Beam Evaporation Recipes#E-Beam 4 .28CHA.29|R2]]
| <br>
|[https://wiki.nanotech.ucsb.edu/w/index.php?title=Sputtering_Recipes#Sputter_3_.28AJA_ATC_2000-F.29 R3]
| <br>
| <br>
|<br>
|{{Rl|Sputtering_Recipes|Sputter_5_.28AJA_ATC_2200-V.29|R3}}
| <br>
|<br>
| [[Sputtering Recipes|R]]
|[[Thermal Evaporation Recipes#Thermal Evaporator 1|R3]]
| <br>
|[[Thermal Evaporation Recipes#Thermal Evaporator 2|R2]]
| <br>
| <br>
|<br>
| <br>
|<br>
| <br>
|<br>
| <br>
|<br>
| <br>
|<br>
| <br>
| <br>
|-
|-
! bgcolor="#D0E7FF" align="center" | Nd
! bgcolor="#d0e7ff" align="center" |Cu
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R1]]
|
| <br>
| bgcolor="#eeffff" |<br>
| <br>
| bgcolor="#eeffff" |<br>
| <br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |[[Sputtering Recipes|R3]]
| <br>
| bgcolor="#eeffff" |[[Sputtering Recipes|R2]]
| <br>
| <br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| [[Sputtering Recipes|A]]
| bgcolor="#eeffff" |[[Thermal Evaporation Recipes#Thermal Evaporator 1|R2]]
| <br>
| bgcolor="#eeffff" |[[Thermal Evaporation Recipes#Thermal Evaporator 2|R1]]
| <br>
| <br>
| bgcolor="#eeffff" |<br>
| <br>
| bgcolor="#eeffff" |<br>
| <br>
| bgcolor="#eeffff" |<br>
| <br>
| bgcolor="#eeffff" |<br>
| <br>
| bgcolor="#eeffff" |<br>
| <br>
| <br>
|-
|-
! bgcolor="#D0E7FF" align="center" | Ni
! bgcolor="#d0e7ff" align="center" |Fe
|[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R2]]
| bgcolor="EEFFFF" | {{Al/E1}}
|<br>
| bgcolor="EEFFFF" | <br>
|<br>
| bgcolor="EEFFFF" | {{Al/E3}}
|[[E-Beam Evaporation Recipes#E-Beam 4 .28CHA.29|R2]]
| bgcolor="EEFFFF" | {{Al/E4}}
|[[Sputtering Recipes|R3]]
| bgcolor="EEFFFF" | <br>
|<br>
| bgcolor="EEFFFF" | <br>
|<br>
| bgcolor="EEFFFF" | {{rl|Sputtering Recipes|Ni deposition (Sputter 3)}}
|<br>
| bgcolor="EEFFFF" | <br>
|[[Thermal Evaporation Recipes#Thermal Evaporator 1|R1]]
| bgcolor="EEFFFF" | <br>
|[[Thermal Evaporation Recipes#Thermal Evaporator 2|R1]]
| bgcolor="EEFFFF" | <br>
|<br>
| bgcolor="EEFFFF" | [[Thermal Evaporation Recipes|A]]
|<br>
| bgcolor="EEFFFF" | [[Thermal Evaporation Recipes|A]]
|<br>
| bgcolor="EEFFFF" | <br>
|<br>
| bgcolor="EEFFFF" | <br>
|<br>
| bgcolor="EEFFFF" | <br>
| bgcolor="EEFFFF" | <br>
| bgcolor="EEFFFF" | <br>
|-
|-
!Ga
! bgcolor="#D0E7FF" align="center" | NiCr
|
| {{Al/E1}}
|
|
|
|
|
| {{Al/E4}}
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|-
|-
!GaAs
! bgcolor="#D0E7FF" align="center" | NiFe
|
| bgcolor="EEFFFF" | {{Al/E1}}
|
| bgcolor="EEFFFF" |
|
| bgcolor="EEFFFF" |
|
| bgcolor="EEFFFF" | {{Al/E4}}
|
| bgcolor="EEFFFF" |
|
| bgcolor="EEFFFF" |
|
| bgcolor="EEFFFF" | [[Sputtering Recipes|A]]
|
| bgcolor="EEFFFF" |
|
| bgcolor="EEFFFF" |
|
| bgcolor="EEFFFF" |
|
| bgcolor="EEFFFF" |
|
| bgcolor="EEFFFF" |
|
| bgcolor="EEFFFF" |
|
| bgcolor="EEFFFF" |
|
| bgcolor="EEFFFF" |
| bgcolor="EEFFFF" |
| bgcolor="EEFFFF" |
|-
|-
! bgcolor="#D0E7FF" align="center" | Pd
! bgcolor="#d0e7ff" align="center" |Ge
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R2]]
| {{Al/E1}}
| <br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 3 .28Temescal.29|R2]]
| {{Al/E3}}
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 4 .28CHA.29|R2]]
| {{Al/E4}}
| bgcolor="#eeffff" |[[Sputtering Recipes|R1]]
| <br>
| bgcolor="#eeffff" |[[Sputtering Recipes|R1]]
| <br>
| <br>
| bgcolor="#eeffff" |<br>
| <br>
| bgcolor="#eeffff" |<br>
| <br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |
| <br>
| bgcolor="#eeffff" |<br>
| [[Thermal Evaporation Recipes|A]]
| bgcolor="#eeffff" |<br>
| [[Thermal Evaporation Recipes|A]]
| <br>
| bgcolor="#eeffff" |<br>
| <br>
| bgcolor="#eeffff" |<br>
| <br>
| bgcolor="#eeffff" |<br>
| <br>
| <br>
|-
|-
! bgcolor="#D0E7FF" align="center" | Pt
! bgcolor="#d0e7ff" align="center" |GeO<sub>2</sub>
|
| bgcolor="EEFFFF" | {{Al/E1}}
|[[E-Beam Evaporation Recipes#E-Beam 2 .28Custom.29|R2]]
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | {{Al/E3}}
|
| bgcolor="EEFFFF" | {{Al/E4}}
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | [[Sputtering Recipes|A]]
|
| bgcolor="EEFFFF" | [[Sputtering Recipes|R]]
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
| bgcolor="EEFFFF" | {{rl|Atomic Layer Deposition Recipes|Pt deposition (ALD)}}
| bgcolor="EEFFFF" | <br>
|-
|-
! bgcolor="#D0E7FF" align="center" | Ru
! bgcolor="#d0e7ff" align="center" |Gd
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R2]]
| {{Al/E1}}
| <br>
| bgcolor="#eeffff" |<br>
| <br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 4 .28CHA.29|R1]]
| {{Al/E4}}
| <br>
| bgcolor="#eeffff" |<br>
| <br>
| bgcolor="#eeffff" |<br>
| <br>
| bgcolor="#eeffff" |<br>
| <br>
| bgcolor="#eeffff" |<br>
| <br>
| bgcolor="#eeffff" |<br>
| <br>
| bgcolor="#eeffff" |<br>
| <br>
| bgcolor="#eeffff" |<br>
| <br>
| bgcolor="#eeffff" |<br>
| <br>
| bgcolor="#eeffff" |<br>
| <br>
| bgcolor="#eeffff" |<br>
| <br>
| bgcolor="#eeffff" |<br>
| <br>
| <br>
|-
|-
! bgcolor="#D0E7FF" align="center" | Si
! bgcolor="#d0e7ff" align="center" |Hf
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R1]]
| bgcolor="EEFFFF" | {{Al/E2}}
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |<br>[[E-Beam Evaporation Recipes#E-Beam 4 .28CHA.29|R1]]
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | [[Sputtering Recipes|A]]
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | [[Sputtering Recipes|A]]
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | {{rl|PECVD Recipes|amorphous-Si deposition (PECVD-2)}}
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | {{rl|PECVD Recipes|amorphous-Si deposition (Unaxis VLR)}}
| bgcolor="EEFFFF" | <br>
| bgcolor="EEFFFF" | <br>
|-
|-
! bgcolor="#D0E7FF" align="center" | SiN
! bgcolor="#d0e7ff" align="center" |HfO<sub>2</sub>
| <br>
|<br>
| <br>
|<br>
| <br>
|<br>
| <br>
|<br>
|[[Sputtering Recipes|R1]]
| <br>
|[[Sputtering Recipes|R1]]
| <br>
|<br>
| {{rl|Sputtering Recipes|SiN deposition (Sputter 3)}}
|<br>
| [[Sputtering Recipes|A]]
| <br>
|<br>
|<br>
| {{rl|Sputtering Recipes|SiN deposition (IBD)}}
| <br>
|<br>
| <br>
|<br>
|<br>
| {{rl|PECVD Recipes|SiN deposition (PECVD #1)}}
| {{rl|PECVD Recipes|SiN deposition (PECVD #2)}}
|[[Atomic Layer Deposition Recipes#AlN deposition .28ALD CHAMBER 3.29|R4]]
|<br>
| {{rl|PECVD Recipes|SiN deposition (Unaxis VLR)}}
| <br>
| <br>
|-
|-
!Hg
! bgcolor="#D0E7FF" align="center" | SiO<sub>2</sub>
|
| bgcolor="EEFFFF" | {{Al/E1}}
|
| bgcolor="EEFFFF" | {{Al/E2}}
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | {{rl|Sputtering Recipes|SiO2 deposition (Sputter 3)}}
|
| bgcolor="EEFFFF" | [[Sputtering Recipes|A]]
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | {{rl|Sputtering Recipes|SiO2 deposition (IBD)}}
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | {{rl|PECVD Recipes|SiO2 deposition (PECVD #1)}}
|
| bgcolor="EEFFFF" | {{rl|PECVD Recipes|SiO2 deposition (PECVD #2)}}
|
| bgcolor="EEFFFF" | {{rl|PECVD Recipes|SiO2 deposition (Unaxis VLR)}}
| bgcolor="EEFFFF" | {{rl|Atomic Layer Deposition Recipes|SiO2 deposition (ALD)}}
| bgcolor="EEFFFF" | <br>
|-
|-
! bgcolor="#D0E7FF" align="center" | SiO<sub>x</sub>N<sub>y</sub>
! bgcolor="#d0e7ff" align="center" |In
| <br>
| bgcolor="#eeffff" |<br>
| <br>
| bgcolor="#eeffff" |<br>
| <br>
| bgcolor="#eeffff" |<br>
| <br>
| bgcolor="#eeffff" |<br>
| <br>
| bgcolor="#eeffff" |<br>
| <br>
| bgcolor="#eeffff" |<br>
| <br>
| bgcolor="#eeffff" |<br>
| <br>
| bgcolor="#eeffff" |<br>
| <br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |[[Thermal Evaporation Recipes#Thermal Evaporator 2|R3]]
| [[Ion_Beam_Deposition_(Veeco_NEXUS)|R]]
| <br>
| bgcolor="#eeffff" |<br>
| <br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| [[PECVD_Recipes#PECVD_1_.28PlasmaTherm_790.29|R]]
| <br>
| bgcolor="#eeffff" |<br>
| <br>
| bgcolor="#eeffff" |<br>
| <br>
| <br>
|-
|-
!InSb
! bgcolor="#D0E7FF" align="center" | Sn
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | [[Thermal Evaporation Recipes|A]]
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
| bgcolor="EEFFFF" | <br>
| bgcolor="EEFFFF" | <br>
|-
|-
! bgcolor="#D0E7FF" align="center" | SrF<sub>2</sub>
! bgcolor="#d0e7ff" align="center" |Ir
|[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R1]]
| <br>
|<br>
| {{Al/E2}}
| <br>
|<br>
|[[E-Beam Evaporation Recipes#E-Beam 4 .28CHA.29|R1]]
| <br>
| <br>
|<br>
| <br>
|<br>
| <br>
|<br>
| <br>
|<br>
|
| <br>
|
| <br>
| <br>
|<br>
| <br>
|<br>
| <br>
|<br>
| <br>
|<br>
| <br>
|<br>
| <br>
| <br>
|-
|-
! bgcolor="#D0E7FF" align="center" | Ta
! bgcolor="#d0e7ff" align="center" |ITO
| bgcolor="EEFFFF" | {{Al/E1}}
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 2 .28Custom.29|R3]]
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |[[Sputtering Recipes|R1]]
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |[[Sputtering Recipes|R1]]
| bgcolor="#eeffff" |R1
| bgcolor="EEFFFF" | {{rl|Sputtering Recipes|Ta deposition (Sputter 3)}}
| bgcolor="EEFFFF" | [[Sputtering Recipes|A]]
| bgcolor="#eeffff" |R1
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | <br>
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" | <br>
| bgcolor="EEFFFF" | <br>
|-
|-
!KCl
! bgcolor="#D0E7FF" align="center" | Ta<sub>2</sub>O<sub>5</sub>
|
| <br>
|
| <br>
|
| <br>
|
| {{Al/E2}}
|
| <br>
|
| <br>
|
| <br>
|
| <br>
|
| <br>
|
| {{rl|Sputtering Recipes|Ta2O5 deposition (IBD)}}
|
| <br>
|
| <br>
|
| <br>
|
| <br>
|
| <br>
| <br>
| <br>
|-
|-
!LiF
! bgcolor="#D0E7FF" align="center" | Ti
|
| bgcolor="EEFFFF" | {{Al/E1}}
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | {{Al/E3}}
|
| bgcolor="EEFFFF" | {{Al/E4}}
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | [[Sputtering Recipes|A]]
|
| bgcolor="EEFFFF" | {{rl|Sputtering Recipes|Ti-Au Deposition (Sputter 4)}}
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
| bgcolor="EEFFFF" | <br>
| bgcolor="EEFFFF" | <br>
|-
|-
!Mg
! bgcolor="#D0E7FF" align="center" | TiN
|
| <br>
|
| <br>
|
| <br>
|
| <br>
|
| <br>
|
| [[Sputtering Recipes|A]]
|
| <br>
|
| [[Sputtering Recipes|R]]
|[[Thermal Evaporation Recipes#Thermal Evaporator 1|R1]]
| <br>
|[[Thermal Evaporation Recipes#Thermal Evaporator 2|R1]]
| [[Ion_Beam_Deposition_(Veeco_NEXUS)|A]]
|
| <br>
|
| <br>
|
| <br>
|
| <br>
|
| <br>
| {{rl|Atomic Layer Deposition Recipes|TiN deposition (ALD)}}
| <br>
|-
|-
! bgcolor="#D0E7FF" align="center" | TiW
! bgcolor="#d0e7ff" align="center" |MgF2
|
| bgcolor="EEFFFF" | {{Al/E1}}
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|[[Sputtering Recipes|R1]]
| bgcolor="EEFFFF" | <br>
|[[Sputtering Recipes|R1]]
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | [[Sputtering Recipes|A]]
|
| bgcolor="EEFFFF" | {{rl|Sputtering Recipes|W-TiW Deposition (Sputter 4)}}
|
| bgcolor="EEFFFF" | <br>
|[[Thermal Evaporation Recipes#Thermal Evaporator 2|R1]]
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
| bgcolor="EEFFFF" | <br>
| bgcolor="EEFFFF" | <br>
|-
|-
! bgcolor="#D0E7FF" align="center" | TiO<sub>2</sub>
! bgcolor="#d0e7ff" align="center" |MgO
|
| bgcolor="EEFFFF" | <br>
|[[E-Beam Evaporation Recipes#E-Beam 2 .28Custom.29|R2]]
| bgcolor="EEFFFF" | {{Al/E2}}
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | {{Rl|Sputtering Recipes|TiO2 deposition (Sputter 2)}}
|
| bgcolor="EEFFFF" | [[Sputtering Recipes|A]]
|
| bgcolor="EEFFFF" | [[Sputtering Recipes|A]]
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | {{Rl|Sputtering Recipes|TiO2 deposition (IBD)}}
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
| bgcolor="EEFFFF" | {{rl|Atomic Layer Deposition Recipes|TiO2 deposition (ALD)}}
| bgcolor="EEFFFF" | <br>
|-
|-
!Mn
! bgcolor="#D0E7FF" align="center" | V
|
| <br>
|
| <br>
|
| <br>
|
| <br>
|
| <br>
|
| <br>
|
| [[Sputtering Recipes|A]]
|
| [[Sputtering Recipes|A]]
|
| <br>
|
| <br>
|
| <br>
|
| <br>
|
| <br>
|
| <br>
|
| <br>
| <br>
| <br>
|-
|-
!MnS
! bgcolor="#D0E7FF" align="center" | W
|
| bgcolor="EEFFFF" | {{Al/E1}}
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | [[Sputtering Recipes|A]]
|
| bgcolor="EEFFFF" | {{rl|Sputtering Recipes|W deposition (Sputter 4)}}
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
| bgcolor="EEFFFF" | <br>
| bgcolor="EEFFFF" | <br>
|-
|-
! bgcolor="#D0E7FF" align="center" | Zn
! bgcolor="#d0e7ff" align="center" |Mo
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R2]]
| <br>
| <br>
| bgcolor="#eeffff" |<br>
| <br>
| bgcolor="#eeffff" |<br>
| <br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |[[Sputtering Recipes|R3]]
| <br>
| bgcolor="#eeffff" |[[Sputtering Recipes|R1]]
| <br>
| <br>
| bgcolor="#eeffff" |<br>
| <br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |
| <br>
| bgcolor="#eeffff" |
| <br>
| bgcolor="#eeffff" |<br>
| [[Thermal Evaporation Recipes|A]]
| bgcolor="#eeffff" |<br>
| [[Thermal Evaporation Recipes|A]]
| <br>
| bgcolor="#eeffff" |<br>
| <br>
| bgcolor="#eeffff" |<br>
| <br>
| bgcolor="#eeffff" |<br>
| <br>
| <br>
|-
|-
!Na
! bgcolor="#D0E7FF" align="center" | ZnO
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
| bgcolor="EEFFFF" | {{rl|Atomic Layer Deposition Recipes|ZnO deposition (ALD)}}
| bgcolor="EEFFFF" | <br>
|-
|-
!NaCl
! bgcolor="#D0E7FF" align="center" | Zr
|
| {{Al/E1}}
|
| <br>
|
| <br>
|
| {{Al/E4}}
|
| <br>
|
| <br>
|
| [[Sputtering Recipes|A]]
|
| [[Sputtering Recipes|A]]
|
| <br>
|
| <br>
|
| <br>
|
| <br>
|
| <br>
|
| <br>
|
| <br>
| <br>
| <br>
|-
|-
! bgcolor="#D0E7FF" align="center" | ZrO<sub>2</sub>
! bgcolor="#d0e7ff" align="center" |Nb
|[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R2]]
| bgcolor="EEFFFF" | <br>
|<br>
| bgcolor="EEFFFF" | <br>
|<br>
| bgcolor="EEFFFF" | <br>
|<br>
| bgcolor="EEFFFF" | <br>
|<br>
| bgcolor="EEFFFF" | <br>
|[[Sputtering Recipes|R3]]
| bgcolor="EEFFFF" | <br>
|<br>
| bgcolor="EEFFFF" | <br>
|<br>
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|
| bgcolor="EEFFFF" | <br>
|<br>
| bgcolor="EEFFFF" | <br>
|<br>
| bgcolor="EEFFFF" | <br>
|<br>
| bgcolor="EEFFFF" | <br>
|<br>
| bgcolor="EEFFFF" | <br>
|<br>
| bgcolor="EEFFFF" | <br>
| bgcolor="EEFFFF" | {{rl|Atomic Layer Deposition Recipes|ZrO2 deposition (ALD)}}
| bgcolor="EEFFFF" | <br>
|-
|-
!NbO5
! width="20" bgcolor="#D0E7FF" align="center" | '''Material'''
|
| width="65" bgcolor="#DAF1FF" | [[E-Beam Evaporation Recipes#E-Beam_1_.28Sharon.29|E-Beam 1 (Sharon)]]
|
| width="65" bgcolor="#DAF1FF" | [[E-Beam Evaporation Recipes#E-Beam_2_.28Custom.29|E-Beam 2 (Custom)]]
|
| width="65" bgcolor="#DAF1FF" | [[E-Beam Evaporation Recipes#E-Beam_3_.28Temescal.29|E-Beam 3 (Temescal)]]
|
| width="65" bgcolor="#DAF1FF" | [[E-Beam Evaporation Recipes#E-Beam_4_.28CHA.29|E-Beam 4 (CHA)]]
|
| width="65" bgcolor="#DAF1FF" | [[Sputtering Recipes#Sputter_1_.28Custom.29|Sputter 1 (Custom)]]
|
| width="65" bgcolor="#DAF1FF" | [[Sputtering Recipes#Sputter_2_.28SFI_Endeavor.29|Sputter 2<br>(SFI Endeavor)]]
|
| width="65" bgcolor="#DAF1FF" | [[Sputtering Recipes#Sputter_3_.28ATC_2000-F.29|Sputter 3<br>(ATC 2000-F)]]
|
| width="65" bgcolor="#DAF1FF" | [[Sputtering Recipes#Sputter_4_.28ATC_2200-V.29|Sputter 4<br>(ATC 2200-V)]]
|
| width="65" bgcolor="#DAF1FF" | [[Sputtering Recipes#Sputter_5_.28Lesker_AXXIS.29|Sputter 5 (Lesker AXXIS)]]
|
| width="55" bgcolor="#DAF1FF" | [[Ion Beam Deposition (Veeco NEXUS)|Ion Beam<br>Deposition (Tool)]]
|
| width="45" bgcolor="#DAF1FF" | [[Thermal Evaporation Recipes#Thermal_Evap_1|Thermal<br>Evap 1]]
|
| width="65" bgcolor="#DAF1FF" | [[Thermal Evaporation Recipes#Thermal_Evap_2_.28Solder.29|Thermal Evap 2 (Solder)]]
|
| width="65" bgcolor="#DAF1FF" | [[PECVD Recipes#PECVD_1_.28PlasmaTherm_790.29|PECVD 1<br>(PlasmaTherm 790)]]
|
| width="65" bgcolor="#DAF1FF" | [[PECVD Recipes#PECVD_2_.28Advanced_Vacuum.29|PECVD 2<br>(Advanced Vacuum)]]
|
| width="65" bgcolor="#DAF1FF" | [[PECVD Recipes#Unaxis_VLR_ICP-PECVD|Unaxis VLR ICP-PECVD]]
|-
| width="65" bgcolor="#DAF1FF" | [[Atomic Layer Deposition (Oxford FlexAL)|Atomic Layer Deposition (Tool)]]
! bgcolor="#d0e7ff" align="center" |Nd
| width="65" bgcolor="#DAF1FF" | [[Molecular Vapor Deposition|Molecular Vapor Deposition (Tool)]]
|
|<br>
|<br>
|<br>
|<br>
|[[Sputtering Recipes|R1]]
|<br>
|<br>
|
|
|<br>
|<br>
|<br>
|<br>
|<br>
|-
! bgcolor="#d0e7ff" align="center" |Ni
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R2]]
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 3 .28Temescal.29|R2]]
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 4 .28CHA.29|R2]]
| bgcolor="#eeffff" |[[Sputtering Recipes|R3]]
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |R1
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |[[Thermal Evaporation Recipes#Thermal Evaporator 1|R3]]
| bgcolor="#eeffff" |[[Thermal Evaporation Recipes#Thermal Evaporator 2|R2]]
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
|-
! bgcolor="#d0e7ff" align="center" |NiCr
|[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R2]]
|
|
|[[E-Beam Evaporation Recipes#E-Beam 4 .28CHA.29|R2]]
|
|
|
|
|[[Thermal Evaporation Recipes#Thermal Evaporator 1|R3]]
|
|
|
|
|
|
|-
! bgcolor="#d0e7ff" align="center" |NiFe
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R1]]
| bgcolor="#eeffff" |
| bgcolor="#eeffff" |
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 4 .28CHA.29|R2]]
| bgcolor="#eeffff" |[[Sputtering Recipes|R1]]
| bgcolor="#eeffff" |
| bgcolor="#eeffff" |
| bgcolor="#eeffff" |
| bgcolor="#eeffff" |[[Thermal Evaporation Recipes#Thermal Evaporator 1|R3]]
| bgcolor="#eeffff" |
| bgcolor="#eeffff" |
| bgcolor="#eeffff" |
| bgcolor="#eeffff" |
| bgcolor="#eeffff" |
| bgcolor="#eeffff" |
|-
!Pb
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|-
!PbS
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|-
! bgcolor="#d0e7ff" align="center" |Pd
|[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R2]]
|<br>
|[[E-Beam Evaporation Recipes#E-Beam 3 .28Temescal.29|R2]]
|[[E-Beam Evaporation Recipes#E-Beam 4 .28CHA.29|R2]]
|<br>
|<br>
|<br>
|<br>
|[[Thermal Evaporation Recipes#Thermal Evaporator 1|R3]]
|[[Thermal Evaporation Recipes#Thermal Evaporator 2|R1]]
|<br>
|<br>
|<br>
|<br>
|<br>
|-
! bgcolor="#d0e7ff" align="center" |Pt
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R2]]
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 3 .28Temescal.29|R2]]
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 4 .28CHA.29|R2]]
| bgcolor="#eeffff" |[[Sputtering Recipes|R3]]
| bgcolor="#eeffff" |[[Sputtering Recipes|R3]]
| bcolor="EEFFFF" |[[Sputtering Recipes|R3]]
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |[[Atomic Layer Deposition Recipes#Pt deposition .28ALD CHAMBER 1.29|R4]]
| bgcolor="#eeffff" |<br>
|-
! bgcolor="#d0e7ff" align="center" |Ru
|[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R2]]
|<br>
|<br>
|[[E-Beam Evaporation Recipes#E-Beam 4 .28CHA.29|R2]]
|<br>
|[[Sputtering Recipes#Ru Deposition .28Sputter 4.29|R3]]
|<br>
|<br>
|<br>
|<br>
|<br>
|<br>
|<br>
|[[Atomic Layer Deposition Recipes#Pt deposition .28ALD CHAMBER 1.29|R4]]
|<br>
|-
!Sb
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|-
!Se
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|-
! bgcolor="#d0e7ff" align="center" |Si
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 2 .28Custom.29|R2]]
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |[[Sputtering Recipes|R3]]
| bgcolor="#eeffff" |[[Sputtering Recipes|R1]]
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |R1
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |[https://wiki.nanotech.ucsb.edu/w/index.php?title=PECVD_Recipes#Amorphous-Si_deposition_.28PECVD_.232.29 R3]
| bgcolor="#eeffff" |
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
|-
! bgcolor="#d0e7ff" align="center" |SiN
|<br>
|<br>
|<br>
|<br>
|[[Sputtering Recipes|R3]]
|[[Sputtering Recipes|R1]]
|<br>
|[[Sputtering Recipes#Si3N4 deposition .28IBD.29|R6]]
|<br>
|<br>
|[[PECVD Recipes#SiN deposition .28PECVD .231.29|R6]]
|[[PECVD Recipes#SiN deposition .28PECVD .232.29|R6]]
|[[PECVD Recipes#ICP-PECVD .28Unaxis VLR.29|R6]]
|<br>
|<br>
|-
! bgcolor="#d0e7ff" align="center" |SiN - Low Stress
|
|
|
|
|
|
|
|
|
|
|[[PECVD Recipes#Low Stress Si3N4 .28PECVD.231.29|R4]]
|[[PECVD Recipes#Low-Stress SiN deposition .28PECVD .232.29|R6]]
|[[PECVD Recipes#ICP-PECVD .28Unaxis VLR.29|R6]]
|
|
|-
! bgcolor="#d0e7ff" align="center" |SiO<sub>2</sub>
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R2]]
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 2 .28Custom.29|R2]]
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |[[Sputtering Recipes|R3]]
| bgcolor="#eeffff" |[[Sputtering Recipes|R1]]
| bgcolor="#eeffff" |[[Sputtering Recipes|R2]]
| bgcolor="#eeffff" |[[Sputtering_Recipes#SiO2_deposition_.28IBD.29|R6]]
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |
| bgcolor="#eeffff" |[[PECVD Recipes#SiO2 deposition .28PECVD .231.29|R6]]
| bgcolor="#eeffff" |[[PECVD Recipes#SiO2 deposition .28PECVD .232.29|R6]]
| bgcolor="#eeffff" |[[PECVD Recipes#ICP-PECVD .28Unaxis VLR.29|R6]]
| bgcolor="#eeffff" |[[Atomic Layer Deposition Recipes#Pt deposition .28ALD CHAMBER 1.29|R4]]
| bgcolor="#eeffff" |<br>
|-
!SiO<sub>x</sub>
|
|[[E-Beam Evaporation Recipes#E-Beam 2 .28Custom.29|R1]]
|
|
|
|
|
|
|
|
|
|
|
|
|
|-
!SiO
|
|
|
|
|
|
|
|
|[[Thermal Evaporation Recipes#Thermal Evaporator 1|R1]]
|[[Thermal Evaporation Recipes#Thermal Evaporator 2|R1]]
|
|
|
|
|
|-
! bgcolor="#d0e7ff" align="center" |SiO<sub>x</sub>N<sub>y</sub>
|<br>
|<br>
|<br>
|<br>
|<br>
|<br>
|<br>
|[[Sputtering Recipes#Si3N4 deposition .28IBD.29|R3]]
|<br>
|<br>
|[[PECVD Recipes#SiO2 deposition .28PECVD .231.29|R4]]
|<br>
|<br>
|<br>
|<br>
|-
! bgcolor="#d0e7ff" align="center" |Sn
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |[[Thermal Evaporation Recipes#Thermal Evaporator 2|R2]]
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
|-
! bgcolor="#d0e7ff" align="center" |SrF<sub>2</sub>
|<br>
|[[E-Beam Evaporation Recipes#E-Beam 2 .28Custom.29|R2]]
|<br>
|<br>
|<br>
|<br>
|<br>
|<br>
|[[Thermal Evaporation Recipes#Thermal Evaporator 1|R1]]
|<br>
|<br>
|<br>
|<br>
|<br>
|<br>
|-
! bgcolor="#d0e7ff" align="center" |Ta
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R1]]
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |[[Sputtering Recipes|R3]]
| bgcolor="#eeffff" |[[Sputtering Recipes|R1]]
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |R1
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
|-
! bgcolor="#d0e7ff" align="center" |Ta<sub>2</sub>O<sub>5</sub>
|<br>
|[[E-Beam Evaporation Recipes#E-Beam 2 .28Custom.29|R1]]
|<br>
|[[E-Beam Evaporation Recipes#E-Beam 4 .28CHA.29|R1]]
|<br>
|<br>
|<br>
|[[Sputtering Recipes#Si3N4 deposition .28IBD.29|R6]]
|<br>
|
|<br>
|<br>
|<br>
|<br>
|<br>
|-
! bgcolor="#d0e7ff" align="center" |Ti
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R2]]
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 3 .28Temescal.29|R2]]
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 4 .28CHA.29|R2]]
| bgcolor="#eeffff" |[[Sputtering Recipes|R3]]
| bgcolor="#eeffff" |[[Sputtering Recipes|R3]]
| bgcolor="#eeffff" |[[Sputtering Recipes|R3]]
| bgcolor="#eeffff" |R1
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
|-
! bgcolor="#d0e7ff" align="center" |TiN
|<br>
|<br>
|<br>
|<br>
|<br>
|[https://wiki.nanotech.ucsb.edu/w/index.php?title=Sputtering_Recipes#Sputter_4_.28AJA_ATC_2200-V.29 R3]
|<br>
|R1
|<br>
|<br>
|<br>
|<br>
|<br>
|[[Atomic Layer Deposition Recipes#Pt deposition .28ALD CHAMBER 1.29|R4]]
|<br>
|-
! bgcolor="#d0e7ff" align="center" |TiW
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R1]]
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |[[Sputtering Recipes|R2]]
| bgcolor="#eeffff" |[[Sputtering Recipes|R3]]
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
|-
!TiO
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|-
! bgcolor="#d0e7ff" align="center" |TiO<sub>2</sub>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 2 .28Custom.29|R2]]
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |[[Sputtering Recipes|R1]]
| bgcolor="#eeffff" |[[Sputtering Recipes|R3]]
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |[[Sputtering Recipes#Si3N4 deposition .28IBD.29|R5]]
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |[[Atomic Layer Deposition Recipes#Pt deposition .28ALD CHAMBER 1.29|R4]]
| bgcolor="#eeffff" |<br>
|-
! bgcolor="#d0e7ff" align="center" |V
|<br>
|<br>
|<br>
|<br>
|[[Sputtering Recipes|R1]]
|[[Sputtering Recipes|R1]]
|<br>
|<br>
|<br>
|
|<br>
|<br>
|<br>
|<br>
|<br>
|-
! bgcolor="#d0e7ff" align="center" |W
| bgcolor="#eeffff" |[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R2]]
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |[[Sputtering Recipes|R2]]
| bgcolor="#eeffff" |[[Sputtering Recipes|R3]]
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
|-
!WC
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|-
! bgcolor="#d0e7ff" align="center" |Zn
|<br>
|<br>
|<br>
|<br>
|<br>
|<br>
|<br>
|<br>
|[[Thermal Evaporation Recipes#Thermal Evaporator 1|R3]]
|[[Thermal Evaporation Recipes#Thermal Evaporator 2|R2]]
|<br>
|<br>
|<br>
|<br>
|<br>
|-
! bgcolor="#d0e7ff" align="center" |ZnO
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |
| bgcolor="#eeffff" |
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |[[Atomic Layer Deposition Recipes#Pt deposition .28ALD CHAMBER 1.29|R3]]
| bgcolor="#eeffff" |<br>
|-
!ZnS
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|-
! bgcolor="#d0e7ff" align="center" |Zr
|[[E-Beam Evaporation Recipes#E-Beam 1 .28Sharon.29|R2]]
|<br>
|<br>
|[[E-Beam Evaporation Recipes#E-Beam 4 .28CHA.29|R2]]
|[[Sputtering Recipes|R1]]
|[[Sputtering Recipes|R1]]
|<br>
|<br>
|<br>
|[[Thermal Evaporation Recipes#Thermal Evaporator 2|R1]]
|<br>
|<br>
|<br>
|<br>
|<br>
|-
! bgcolor="#d0e7ff" align="center" |ZrO<sub>2</sub>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |<br>
| bgcolor="#eeffff" |[[Atomic Layer Deposition Recipes#Pt deposition .28ALD CHAMBER 1.29|R4]]
| bgcolor="#eeffff" |<br>
|-
! width="20" bgcolor="#d0e7ff" align="center" |'''Material'''
| width="65" bgcolor="#daf1ff" |[[E-Beam Evaporation Recipes#E-Beam_1_.28Sharon.29|E-Beam 1 (Sharon)]]
| width="65" bgcolor="#daf1ff" |[[E-Beam Evaporation Recipes#E-Beam_2_.28Custom.29|E-Beam 2 (Custom)]]
| width="65" bgcolor="#daf1ff" |[[E-Beam Evaporation Recipes#E-Beam_3_.28Temescal.29|E-Beam 3 (Temescal)]]
| width="65" bgcolor="#daf1ff" |[[E-Beam Evaporation Recipes#E-Beam_4_.28CHA.29|E-Beam 4 (CHA)]]
| width="65" bgcolor="#daf1ff" |[[Sputtering Recipes#Sputter_3_.28ATC_2000-F.29|Sputter 3<br>(ATC 2000-F)]]
| width="65" bgcolor="#daf1ff" |[[Sputtering_Recipes#Sputter_4_.28AJA_ATC_2200-V.29|Sputter 4<br>(ATC 2200-V)]]
| width="65" bgcolor="#daf1ff" |[[Sputtering Recipes|Sputter 5 (ATC 2200-V)]]
| width="55" bgcolor="#daf1ff" |[[Sputtering_Recipes#Ion_Beam_Deposition_.28Veeco_NEXUS.29|Ion Beam<br>Deposition (Veeco Nexus)]]
| width="45" bgcolor="#daf1ff" |[[Thermal Evaporation Recipes#Thermal_Evap_1|Thermal<br>Evap 1]]
| width="65" bgcolor="#daf1ff" |[[Thermal Evaporation Recipes#Thermal_Evap_2_.28Solder.29|Thermal Evap 2 (Solder)]]
| width="65" bgcolor="#daf1ff" |[[PECVD Recipes#PECVD_1_.28PlasmaTherm_790.29|PECVD 1<br>(PlasmaTherm 790)]]
| width="65" bgcolor="#daf1ff" |[[PECVD Recipes#PECVD_2_.28Advanced_Vacuum.29|PECVD 2<br>(Advanced Vacuum)]]
| width="65" bgcolor="#daf1ff" |[[PECVD_Recipes#ICP-PECVD_.28Unaxis_VLR.29|Unaxis VLR ICP-PECVD]]
| width="65" bgcolor="#daf1ff" |[[Atomic_Layer_Deposition_Recipes|Atomic Layer Deposition (Oxford FlexAl)]]
| width="65" bgcolor="#daf1ff" |[[Molecular Vapor Deposition|Molecular Vapor Deposition (Tool)]]
|}
|}


===Process Ranking Table===
Processes in the table above are ranked by their "''Process Maturity Level''" as follows:
{| class="wikitable"
|'''Process Level'''
| colspan="11" |'''Description of Process Level Ranking'''
|-
|A
| colspan="11" |Process '''A'''llowed and materials available but never done
|-
|R1
| colspan="11" |Process has been ran at least once
|-
|R2
| colspan="11" |Process has been ran and/or procedure is documented or/and data available
|-
|R3
| colspan="11" |Process has been ran, procedure is documented, and data is available
|-
|R4
| colspan="11" |Process has a documented procedure with regular (≥4x per year) data '''or''' lookahead/in-Situ control available
|-
|R5
| colspan="11" |Process has a documented procedure with regular (≥4x per year) data '''and''' lookahead/in-Situ control available
|-
|R6
| colspan="11" |Process has a documented procedure, regular ( ≥4x per year) data, and control charts/limits available
|}
[[Category:Processing]]
[[Category:Processing]]

Latest revision as of 16:43, 27 November 2024

Process Control Data

See linked page for process control data (calibration data over time, such as dep. rate, refractive index, stress etc.) over time, for a selection of highly used tools/films.

Deposition Tools/Materials Table

The Key/Legend for this table's A...R6 values is at the bottom of the page.

Vacuum Deposition Recipes

E-Beam Evaporation Sputtering Thermal Evaporation Plasma Enhanced Chemical
Vapor Deposition (PECVD)
Atomic Layer Deposition Molecular Vapor Deposition
Material E-Beam 1 (Sharon) E-Beam 2 (Custom) E-Beam 3 (Temescal) E-Beam 4 (CHA) Sputter 3
(AJA ATC 2000-F)
Sputter 4
(AJA ATC 2200-V)
Sputter 5 (AJA ATC 2200-V) Ion Beam
Deposition (Veeco Nexus)
Thermal
Evap 1
Thermal Evap 2 (Solder) PECVD 1
(PlasmaTherm 790)
PECVD 2
(Advanced Vacuum)
Unaxis VLR ICP-PECVD Atomic Layer Deposition (Oxford FlexAL) Molecular Vapor Deposition (Tool)
Ag R2
R2 R2 R1 R1

R1 R1




AgBr
AgCl
Al R2
R2 R2 R1 R3 R1 R1 R3 R1




Al2O3 R2

R3 R3 R1 R5




R4
As
AuPd R1
AuZn R1
AuSn R1
AuGe R1
AlN



R1 R1
R1




R4
Au R2
R2 R2 R1 R3

R3 R2




B













Be
C R3
Cd
CdS
CdTe
CaF2 R2
CeO2
R3












Co R2

R2 R3


R1 R1




Cr R1

R2 R3
R3
R3 R2




Cu R1


R3 R2

R2 R1




Fe R2

R2 R3


R1 R1




Ga
GaAs
Ge R2
R2 R2 R1 R1







GeO2 R2
Gd R2

R1










Hf R1


R1











HfO2



R1 R1






R4
Hg
In








R3




InSb
Ir R1

R1








ITO
R3

R1 R1 R1 R1






KCl
LiF
Mg R1 R1
MgF2 R1 R1 R1
MgO R2
Mn
MnS
Mo R2


R3 R1






Na
NaCl
Nb R2



R3






NbO5
Nd



R1






Ni R2
R2 R2 R3
R1
R3 R2




NiCr R2 R2 R3
NiFe R1 R2 R1 R3
Pb
PbS
Pd R2
R2 R2



R3 R1




Pt R2
R2 R2 R3 R3 R3




R4
Ru R2

R2
R3






R4
Sb
Se
Si
R2

R3 R1
R1

R3

SiN



R3 R1
R6

R6 R6 R6

SiN - Low Stress R4 R6 R6
SiO2 R2 R2

R3 R1 R2 R6
R6 R6 R6 R4
SiOx R1
SiO R1 R1
SiOxNy






R3

R4



Sn








R2




SrF2
R2





R1





Ta R1


R3 R1
R1





Ta2O5
R1
R1


R6





Ti R2
R2 R2 R3 R3 R3 R1





TiN




R3
R1




R4
TiW R1


R2 R3








TiO
TiO2
R2

R1 R3
R5



R4
V



R1 R1







W R2


R2 R3







WC
Zn







R3 R2




ZnO










R3
ZnS
Zr R2

R2 R1 R1


R1




ZrO2











R4
Material E-Beam 1 (Sharon) E-Beam 2 (Custom) E-Beam 3 (Temescal) E-Beam 4 (CHA) Sputter 3
(ATC 2000-F)
Sputter 4
(ATC 2200-V)
Sputter 5 (ATC 2200-V) Ion Beam
Deposition (Veeco Nexus)
Thermal
Evap 1
Thermal Evap 2 (Solder) PECVD 1
(PlasmaTherm 790)
PECVD 2
(Advanced Vacuum)
Unaxis VLR ICP-PECVD Atomic Layer Deposition (Oxford FlexAl) Molecular Vapor Deposition (Tool)

Process Ranking Table

Processes in the table above are ranked by their "Process Maturity Level" as follows:

Process Level Description of Process Level Ranking
A Process Allowed and materials available but never done
R1 Process has been ran at least once
R2 Process has been ran and/or procedure is documented or/and data available
R3 Process has been ran, procedure is documented, and data is available
R4 Process has a documented procedure with regular (≥4x per year) data or lookahead/in-Situ control available
R5 Process has a documented procedure with regular (≥4x per year) data and lookahead/in-Situ control available
R6 Process has a documented procedure, regular ( ≥4x per year) data, and control charts/limits available