Dry Etching Recipes: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
(changed OXFD GaN etch to R6) |
||
(193 intermediate revisions by 7 users not shown) | |||
Line 1: | Line 1: | ||
===<u>[[Process Group - Process Control Data#Etching .28Process Control Data.29|Process Control Data]]</u>=== |
|||
{{Recipe Table Explanation}} |
|||
<small>''See above [[Process Group - Process Control Data#Etching .28Process Control Data.29|linked page]] for [https://en.wikipedia.org/wiki/Statistical_process_control process control data] (dep rate/stress etc. over time), for a selection of often-used dry etches''</small> |
|||
{| border="1" class="wikitable" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center; font-size: 95%" |
|||
|- bgcolor="#D0E7FF" |
|||
===Dry Etching Tools/Materials Table=== |
|||
! width="725" height="45" colspan="15" | <div style="font-size: 150%;">Dry Etching Recipes</div> |
|||
''The Key/Legend for this table's <code>A...R6</code> values is at the [[Dry Etching Recipes#Process Ranking Table|bottom of the page]].'' |
|||
|- bgcolor="#D0E7FF" |
|||
{| class="wikitable" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center; font-size: 95%" border="1" |
|||
| <!-- INTENTIONALLY LEFT BLANK --> |
|||
|- |
|||
! width="300" bgcolor="#D0E7FF" align="center" height="35" colspan="4" | '''[[RIE Etching Recipes|RIE Etching]]''' |
|||
! |
! colspan="15" width="725" height="45" |<div style="font-size: 150%;">Dry Etching Recipes</div> |
||
|- bgcolor="#d0e7ff" |
|||
! bgcolor="#D0E7FF" align="center" colspan="4"|'''[[Oxygen Plasma System Recipes|Oxygen Plasma Systems]]''' |
|||
| bgcolor="#eaecf0" |<!-- INTENTIONALLY LEFT BLANK --> |
|||
! bgcolor="#D0E7FF" align="center"|'''[[Other Dry Etcher Recipes|Other Dry Etchers]]''' |
|||
! colspan="2" |'''[[RIE Etching Recipes|RIE Etching]]''' |
|||
! colspan="5" |'''[[ICP Etching Recipes|ICP Etching]]''' |
|||
! colspan="4" bgcolor="#d0e7ff" align="center" |'''[[Oxygen Plasma System Recipes|Oxygen Plasma Systems]]''' |
|||
! colspan="3" bgcolor="#d0e7ff" align="center" |'''[[Other Dry Etching Recipes|Other Dry Etchers]]''' |
|||
|- bgcolor="#d0e7ff" |
|||
! bgcolor="#d0e7ff" align="center" |'''Material''' |
|||
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_2_.28MRC.29|RIE 2<br> <span style="font-size: 88%;">(MRC)</span>]] |
|||
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_5_.28PlasmaTherm.29|RIE 5<br><span style="font-size: 88%;">(PlasmaTherm)</span>]] |
|||
| bgcolor="#daf1ff" |[[ICP_Etching_Recipes#DSEIII_.28PlasmaTherm.2FDeep_Silicon_Etcher.29|DSEIII<br><span style="font-size: 88%;">(PlasmaTherm)</span>]] |
|||
| bgcolor="#daf1ff" |[[ICP Etching Recipes#PlasmaTherm.2FSLR Fluorine Etcher|Fluorine ICP <span style="font-size: 88%;">(PlasmaTherm)</span>]] |
|||
| bgcolor="#daf1ff" |[[ICP Etching Recipes#ICP Etch 1 .28Panasonic E646V.29|ICP Etch 1<br><span style="font-size: 88%;">(Panasonic E646V)</span>]] |
|||
| bgcolor="#daf1ff" |[[ICP Etching Recipes#ICP Etch 2 .28Panasonic E626I.29|ICP Etch 2<br><span style="font-size: 88%;">(Panasonic E626I)</span>]] |
|||
| bgcolor="#daf1ff" |[[ICP Etching Recipes#Oxford ICP Etcher .28PlasmaPro 100 Cobra.29|Oxford ICP <span style="font-size: 88%;">(PlasmaPro 100)</span>]] |
|||
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#Ashers_.28Technics_PEII.29|Ashers<br><span style="font-size: 88%;">(Technics PEII)</span>]] |
|||
| bgcolor="#daf1ff" |[[Oxygen Plasma System Recipes#Plasma Clean .28YES EcoClean.29|Plasma Clean <span style="font-size: 88%;">(YES EcoClean)</span>]] |
|||
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#UV_Ozone_Reactor|UV Ozone Reactor]] |
|||
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#Plasma_Activation_.28EVG_810.29|Plasma Activation<br><span style="font-size: 88%;">(EVG 810)</span>]] |
|||
| bgcolor="#daf1ff" |[[Other_Dry_Etching_Recipes#XeF2_Etch_.28Xetch.29|XeF2 Etch<br><span style="font-size: 88%;">(Xetch)</span>]] |
|||
| bgcolor="#daf1ff" |[[Other_Dry_Etching_Recipes#Vapor_HF_Etch_.28uETCH.29|Vapor HF Etch<br><span style="font-size: 88%;">(uETCH)</span>]] |
|||
| bgcolor="#daf1ff" |[[Other_Dry_Etching_Recipes#CAIBE_.28Oxford_Ion_Mill.29|CAIBE<br><span style="font-size: 88%;">(Oxford)</span>]] |
|||
|- bgcolor="#eeffff" |
|||
! bgcolor="#d0e7ff" align="center" |Ag |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|R1 |
|||
|- bgcolor="#ffffff" |
|||
! bgcolor="#d0e7ff" align="center" |Al |
|||
| |
|||
|[[RIE Etching Recipes|R2]] |
|||
| |
|||
| |
|||
|{{rl|ICP Etching Recipes|Al Etch (Panasonic 1)|R1}} |
|||
|[[ICP Etching Recipes#Al Etch .28Panasonic 2.29|R2]] |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|R1 |
|||
|- bgcolor="#eeffff" |
|||
! bgcolor="#d0e7ff" align="center" |Au |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|[[Other Dry Etching Recipes|R4]] |
|||
|- bgcolor="#ffffff" |
|||
! bgcolor="#d0e7ff" align="center" |Cr |
|||
| |
|||
|[[RIE Etching Recipes|R2]] |
|||
| |
|||
| |
|||
|{{rl|ICP Etching Recipes|Cr Etch (Panasonic 1)}} |
|||
|R1 |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|R1 |
|||
|- bgcolor="#eeffff" |
|||
! bgcolor="#d0e7ff" align="center" |Cu |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|R1 |
|||
|- bgcolor="#ffffff" |
|||
! bgcolor="#d0e7ff" align="center" |Ge |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|A |
|||
|R1 |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|[[Other Dry Etching Recipes|R2]] |
|||
| |
|||
|R1 |
|||
|- bgcolor="#eeffff" |
|||
! bgcolor="#d0e7ff" align="center" |Mo |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|R1 |
|||
|- |
|- |
||
!Nb |
|||
! width="65" bgcolor="#D0E7FF" align="center" | '''Material''' |
|||
| |
|||
| width="65" bgcolor="#DAF1FF" | [[RIE 1 (Custom)|RIE 1<br>(Custom)]] |
|||
| |
|||
| width="65" bgcolor="#DAF1FF" | [[RIE 2 (MRC)|RIE 2<br> (MRC)]] |
|||
| |
|||
| width="65" bgcolor="#DAF1FF" | [[RIE 3 (MRC)|RIE 3<br> (MRC)]] |
|||
| |
|||
| width="100" bgcolor="#DAF1FF" | [[RIE 5 (PlasmaTherm)|RIE 5<br>(PlasmaTherm)]] |
|||
|A |
|||
| width="160" bgcolor="#DAF1FF" | [[Si Deep RIE (PlasmaTherm/Bosch Etch)|Si Deep RIE<br>(PlasmaTherm/Bosch Etch)]] |
|||
|R1 |
|||
| width="120" bgcolor="#DAF1FF" | [[ICP Etch 1 (Panasonic E626I)|ICP Etch 1<br>(Panasonic E626I)]] |
|||
| |
|||
| width="120" bgcolor="#DAF1FF" | [[ICP Etch 2 (Panasonic E640)|ICP Etch 2<br>(Panasonic E640)]] |
|||
| |
|||
| width="85" bgcolor="#DAF1FF" | [[ICP-Etch (Unaxis VLR)|ICP-Etch<br>(Unaxis VLR)]] |
|||
| |
|||
| width="85" bgcolor="#DAF1FF" | [[Ashers (Technics PEII)|Ashers<br>(Technics PEII)]] |
|||
| |
|||
| width="95" bgcolor="#DAF1FF" | [[Plasma Clean (Gasonics 2000)|Plasma Clean<br>(Gasonics 2000)]] |
|||
| |
|||
| width="85" bgcolor="#DAF1FF" | [[UV Ozone Reactor]] |
|||
| |
|||
| width="85" bgcolor="#DAF1FF" | [[Plasma Activation (EVG 810)|Plasma Activation<br>(EVG 810)]] |
|||
| |
|||
| width="85" bgcolor="#DAF1FF" | [[XeF2 Etch (Xetch)|XeF2 Etch<br>(Xetch)]] |
|||
| |
|||
|-bgcolor ="#EEFFFF" |
|||
|- bgcolor="#ffffff" |
|||
! bgcolor="#d0e7ff" align="center" |Ni |
|||
| |
|||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
|||
| {{rl|ICP Etching Recipes|Al Etch(Panasonic 1)}} |
|||
| |
|||
| {{rl|ICP Etching Recipes|Al Etch(Panasonic 2)}} |
|||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
|||
|[[Other Dry Etching Recipes|R4]] |
|||
|- |
|- |
||
!Os |
|||
! bgcolor="#D0E7FF" align="center" | Ti |
|||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
|A |
||
|R1 |
|||
| {{rl|ICP Etching Recipes|Ti Etch(Panasonic 1)}} |
|||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
|||
|-bgcolor ="#EEFFFF" |
|||
|- bgcolor="#eeffff" |
|||
! bgcolor="#d0e7ff" align="center" |Pt |
|||
| |
|||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
|||
| {{rl|ICP Etching Recipes|Cr Etch(Panasonic 1)}} |
|||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
|||
|[[Other Dry Etching Recipes|R4]] |
|||
|- bgcolor="#ffffff" |
|||
! bgcolor="#d0e7ff" align="center" |Ru |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|A |
|||
|[[ICP Etching Recipes#Ru .28Ruthenium.29 Etch .28Panasonic 2.29|R3]] |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|R1 |
|||
|- bgcolor="#eeffff" |
|||
! bgcolor="#d0e7ff" align="center" |Si |
|||
| |
|||
| |
|||
|[[ICP Etching Recipes#DSEIII .28PlasmaTherm.2FDeep Silicon Etcher.29|R6]] |
|||
|[[ICP Etching Recipes#Si Etching .28Fluorine ICP Etcher.29|R6]] |
|||
| |
|||
| |
|||
|R1 |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|[[Other Dry Etching Recipes|R4]] |
|||
| |
|||
|R1 |
|||
|- bgcolor="#ffffff" |
|||
! bgcolor="#d0e7ff" align="center" |Ta |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|A |
|||
|R1 |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|R1 |
|||
|- bgcolor="#eeffff" |
|||
! bgcolor="#d0e7ff" align="center" |Ti |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|{{rl|ICP Etching Recipes|Ti Etch (Panasonic 1)}} |
|||
|R1 |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|R1 |
|||
|- bgcolor="#ffffff" |
|||
! bgcolor="#d0e7ff" align="center" |W |
|||
| |
|||
| |
|||
| |
|||
|R2 |
|||
|{{rl|ICP Etching Recipes|W-TiW Etch (Panasonic 1)}} |
|||
|R1 |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|R1 |
|||
|- |
|- |
||
!TiW |
|||
! bgcolor="#D0E7FF" align="center" | Ge |
|||
| |
| |
||
| |
| |
||
| |
| |
||
| |
|R2 |
||
| |
| |
||
| |
|R1 |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
|||
|-bgcolor ="#EEFFFF" |
|||
|- bgcolor="#ffffff" |
|||
! bgcolor="#d0e7ff" align="center" |Al<sub>2</sub>O<sub>3</sub> |
|||
| |
|||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
|A |
||
|[[ICP Etching Recipes#Al2O3 Etching .28Panasonic 2.29|R3]] |
|||
| |
|||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
|||
|R1 |
|||
|- bgcolor="#eeffff" |
|||
! bgcolor="#d0e7ff" align="center" |Al<sub>2</sub>O<sub>3 (Sapphire)</sub> |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|{{rl|ICP Etching Recipes|Sapphire Etch (Panasonic 1)}} |
|||
|R1 |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|R1 |
|||
|- bgcolor="#ffffff" |
|||
! bgcolor="#d0e7ff" align="center" |AlGaAs |
|||
| |
|||
|[[RIE Etching Recipes|R3]] |
|||
| |
|||
| |
|||
|{{rl|ICP Etching Recipes|GaAs-AlGaAs Etch (Panasonic 1)}} |
|||
| |
|||
|[[ICP Etching Recipes#GaAs Etch .28Oxford ICP Etcher.29|R3]] |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|R1 |
|||
|- bgcolor="#eeffff" |
|||
! bgcolor="#d0e7ff" align="center" |AlGaN |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|[[ICP Etching Recipes#GaN Etch .28Oxford ICP Etcher.29|R2]] |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|R1 |
|||
|- bgcolor="#ffffff" |
|||
! bgcolor="#d0e7ff" align="center" |AlN |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|R1 |
|||
|- |
|- |
||
!BCB |
|||
! bgcolor="#D0E7FF" align="center" | Ru |
|||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
|A |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
|||
|-bgcolor ="#EEFFFF" |
|||
|- bgcolor="#eeffff" |
|||
! bgcolor="#d0e7ff" align="center" |CdZnTe |
|||
| |
|||
|[[RIE Etching Recipes|R3]] |
|||
| |
|||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
|||
|R1 |
|||
|- bgcolor="#ffffff" |
|||
! bgcolor="#d0e7ff" align="center" |GaAs |
|||
| |
|||
|[[RIE Etching Recipes|R4]] |
|||
| |
|||
| |
|||
|{{rl|ICP Etching Recipes|GaAs-AlGaAs Etch (Panasonic 1)}} |
|||
|[[ICP Etching Recipes#GaAs Etch .28Panasonic 2.29|R3]] |
|||
|[[ICP Etching Recipes#GaAs Etch .28Oxford ICP Etcher.29|R2]] |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|R1 |
|||
|- bgcolor="#eeffff" |
|||
! bgcolor="#d0e7ff" align="center" |GaN |
|||
| |
|||
|[[RIE Etching Recipes|R4]] |
|||
| |
|||
| |
|||
|{{rl|ICP Etching Recipes|GaN Etch (Panasonic 1)}} |
|||
|R1 |
|||
|[[ICP Etching Recipes#GaN Etch .28Oxford ICP Etcher.29|R6]] |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|R1 |
|||
|- bgcolor="#ffffff" |
|||
! bgcolor="#d0e7ff" align="center" |GaSb |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|A |
|||
|R1 |
|||
|R1 |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|R1 |
|||
|- bgcolor="#eeffff" |
|||
! bgcolor="#d0e7ff" align="center" |HfO<sub>2</sub> |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|R1 |
|||
|- bgcolor="#ffffff" |
|||
! bgcolor="#d0e7ff" align="center" |InGaAlAs |
|||
|[[RIE Etching Recipes|R4]] |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|R1 |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|R1 |
|||
|- bgcolor="#eeffff" |
|||
! bgcolor="#d0e7ff" align="center" |InGaAsP |
|||
|[[RIE Etching Recipes|R4]] |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|[[ICP Etching Recipes#InP Ridge Etch .28Oxford ICP Etcher.29|R3]] |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|R1 |
|||
|- bgcolor="#ffffff" |
|||
! bgcolor="#d0e7ff" align="center" |InP |
|||
|[[RIE Etching Recipes|R4]] |
|||
| |
|||
| |
|||
| |
|||
|A |
|||
|R1 |
|||
|[[ICP Etching Recipes#InP Ridge Etch .28Oxford ICP Etcher.29|R6]] |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|[[Other Dry Etching Recipes|R4]] |
|||
|- bgcolor="#eeffff" |
|||
! bgcolor="#d0e7ff" align="center" |ITO |
|||
|[[RIE Etching Recipes|R4]] |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|R1 |
|||
|- |
|- |
||
!LiNbO3 |
|||
! bgcolor="#D0E7FF" align="center" | Ta |
|||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
|R1 |
|||
|-bgcolor ="#EEFFFF" |
|||
|- bgcolor="#ffffff" |
|||
!Photoresist & Organics |
|||
| |
|||
| |
| |
||
|[[RIE Etching Recipes|R3]] |
|||
| |
|||
| |
| |
||
|[[ICP Etching Recipes#Photoresist .26 ARC .28Fluorine ICP Etcher.29|R3]] |
|||
| |
|||
|[https://wiki.nanotech.ucsb.edu/wiki/ICP_Etching_Recipes#Photoresist_and_ARC_Etching_.28Panasonic_1.29 R] |
|||
| {{rl|ICP Etching Recipes|W-TiW Etch(Panasonic 1)}} |
|||
|[[ICP Etching Recipes#Al2O3 Etching .28Panasonic 2.29|R3]] |
|||
| A |
|||
| |
| |
||
| |
|R3 |
||
|[[Oxygen Plasma System Recipes#O2 Ashing|R3]] |
|||
| |
|||
|[[Oxygen Plasma System Recipes#O2 Ashing|R3]] |
|||
| |
|||
| |
| |
||
| |
| |
||
| |
|||
|R1 |
|||
|- |
|- |
||
!ARC (Anti Reflective Coating) |
|||
! bgcolor="#D0E7FF" align="center" | Al<sub>2</sub>O<sub>3</sub> |
|||
| |
| |
||
| |
| |
||
| |
| |
||
|[[ICP Etching Recipes#Photoresist .26 ARC .28Fluorine ICP Etcher.29|R3]] |
|||
| |
|||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
|||
|-bgcolor ="#EEFFFF" |
|||
|- bgcolor="#eeffff" |
|||
! bgcolor="#d0e7ff" align="center" |SiC |
|||
| |
|||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
|{{rl|ICP Etching Recipes|SiC Etch (Panasonic 1)}} |
|||
| |
|||
| |
|R1 |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
|||
|R1 |
|||
|- bgcolor="#ffffff" |
|||
! bgcolor="#d0e7ff" align="center" |SiN |
|||
| |
|||
| |
|||
| |
|||
|[[ICP Etching Recipes#Si3N4 Etching .28Fluorine ICP Etcher.29|R3]] |
|||
|{{rl|ICP Etching Recipes|SiNx Etching (Panasonic 1)}} |
|||
|[[ICP Etching Recipes#SiNx Etching .28Panasonic 2.29|R3]] |
|||
| |
|||
|[[Oxygen Plasma System Recipes#O2 Ashing|R3]] |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|R1 |
|||
|- bgcolor="#eeffff" |
|||
! bgcolor="#d0e7ff" align="center" |SiO<sub>2</sub> |
|||
| |
|||
| |
|||
| |
|||
|[[ICP Etching Recipes#SiO2 Etching .28Fluorine ICP Etcher.29|R6]] |
|||
|{{rl|ICP Etching Recipes|SiO2 Etching (Panasonic 1)}} |
|||
|[[ICP Etching Recipes#SiO2 Etching .28Panasonic 2.29|R6]] |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|[[Other Dry Etching Recipes|R4]] |
|||
|R1 |
|||
|- bgcolor="#ffffff" |
|||
! bgcolor="#d0e7ff" align="center" |SiOxNy |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|A |
|||
|R1 |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|R1 |
|||
|- |
|- |
||
!SU8 |
|||
! bgcolor="#D0E7FF" align="center" | ITo |
|||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
|A |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
|||
|-bgcolor ="#EEFFFF" |
|||
|- bgcolor="#eeffff" |
|||
! bgcolor="#d0e7ff" align="center" |Ta<sub>2</sub>O<sub>5</sub> |
|||
| |
|||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
|A |
|||
| {{rl|ICP Etching Recipes|SIO2Etch(Panasonic 1)}} |
|||
|R1 |
|||
| {{rl|ICP Etching Recipes|SIO2Etch(Panasonic 2)}} |
|||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
|||
| |
|||
| |
|||
|R1 |
|||
|- bgcolor="#ffffff" |
|||
! bgcolor="#d0e7ff" align="center" |TiN |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|R1 |
|||
|- bgcolor="#eeffff" |
|||
! bgcolor="#d0e7ff" align="center" |TiO<sub>2</sub> |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|R1 |
|||
|- bgcolor="#eeffff" |
|||
! bgcolor="#d0e7ff" align="center" |ZnO<sub>2</sub> |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|R1 |
|||
|- bgcolor="#ffffff" |
|||
! bgcolor="#d0e7ff" align="center" |ZnS |
|||
|[[RIE Etching Recipes|R3]] |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|R1 |
|||
|- bgcolor="#eeffff" |
|||
! bgcolor="#d0e7ff" align="center" |ZnSe |
|||
|[[RIE Etching Recipes|R2]] |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|R1 |
|||
|- bgcolor="#ffffff" |
|||
! bgcolor="#d0e7ff" align="center" |ZrO<sub>2</sub> |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|R1 |
|||
|- bgcolor="#eeffff" |
|||
! bgcolor="#d0e7ff" align="center" |'''Material''' |
|||
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_2_.28MRC.29|RIE 2<br> <span style="font-size: 88%;">(MRC)</span>]] |
|||
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_5_.28PlasmaTherm.29|RIE 5<br><span style="font-size: 88%;">(PlasmaTherm)</span>]] |
|||
| bgcolor="#daf1ff" |[[ICP_Etching_Recipes#DSEIII_.28PlasmaTherm.2FDeep_Silicon_Etcher.29|DSEIII<br><span style="font-size: 88%;">(PlasmaTherm)</span>]] |
|||
| bgcolor="#daf1ff" |[[ICP Etching Recipes#PlasmaTherm.2FSLR Fluorine Etcher|Fluorine ICP <span style="font-size: 88%;">(PlasmaTherm)</span>]] |
|||
| bgcolor="#daf1ff" |[[ICP Etching Recipes#ICP Etch 1 .28Panasonic E646V.29|ICP Etch 1<br><span style="font-size: 88%;">(Panasonic E626I)</span>]] |
|||
| bgcolor="#daf1ff" |[[ICP Etching Recipes#ICP Etch 2 .28Panasonic E626I.29|ICP Etch 2<br><span style="font-size: 88%;">(Panasonic E640)</span>]] |
|||
| bgcolor="#daf1ff" |[[ICP Etching Recipes#Oxford ICP Etcher .28PlasmaPro 100 Cobra.29|Oxford ICP <span style="font-size: 88%;">(PlasmaPro 100)</span>]] |
|||
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#Ashers_.28Technics_PEII.29|Ashers<br><span style="font-size: 88%;">(Technics PEII)</span>]] |
|||
| bgcolor="#daf1ff" |[[Oxygen Plasma System Recipes#Plasma Clean .28YES EcoClean.29|Plasma Clean <span style="font-size: 88%;">(YES EcoClean)</span>]] |
|||
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#UV_Ozone_Reactor|UV Ozone Reactor]] |
|||
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#Plasma_Activation_.28EVG_810.29|Plasma Activation<br><span style="font-size: 88%;">(EVG 810)</span>]] |
|||
| bgcolor="#daf1ff" |[[Other_Dry_Etching_Recipes#XeF2_Etch_.28Xetch.29|XeF2 Etch<br><span style="font-size: 88%;">(Xetch)</span>]] |
|||
| bgcolor="#daf1ff" |[[Other_Dry_Etching_Recipes#Vapor_HF_Etch_.28uETCH.29|Vapor HF Etch<br><span style="font-size: 88%;">(uETCH)</span>]] |
|||
| bgcolor="#daf1ff" |[[Other_Dry_Etching_Recipes#CAIBE_.28Oxford_Ion_Mill.29|CAIBE<br><span style="font-size: 88%;">(Oxford)</span>]] |
|||
|} |
|||
==='''Process Ranking Table'''=== |
|||
Processes in the table above are ranked by their "''Process Maturity Level''" as follows: |
|||
{| class="wikitable" |
|||
!Process Level |
|||
! colspan="11" |Description of Process Level Ranking |
|||
|- |
|- |
||
|A |
|||
! bgcolor="#D0E7FF" align="center" | SiN |
|||
| colspan="11" |Process '''A'''llowed and materials available but never done |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| {{rl|ICP Etching Recipes|SINxEtch(Panasonic 1)}} |
|||
| {{rl|ICP Etching Recipes|SINxEtch(Panasonic 2)}} |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|-bgcolor ="#EEFFFF" |
|||
! bgcolor="#D0E7FF" align="center" | SiOxNy |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|- |
|- |
||
|R1 |
|||
! bgcolor="#D0E7FF" align="center" | Ta<sub>2</sub>O<sub>5</sub> |
|||
| colspan="11" |Process has been run at least once |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|-bgcolor ="#EEFFFF" |
|||
! bgcolor="#D0E7FF" align="center" | TiO<sub>2</sub> |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|- |
|- |
||
|R2 |
|||
! bgcolor="#D0E7FF" align="center" | TiN |
|||
| colspan="11" |Process has been run and/or procedure is documented or/and data available |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|-bgcolor ="#EEFFFF" |
|||
! bgcolor="#D0E7FF" align="center" | ZnO<sub>2</sub> |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|- |
|- |
||
|R3 |
|||
! bgcolor="#D0E7FF" align="center" | ZrO<sub>2</sub> |
|||
| colspan="11" |Process has been run, procedure is documented, and data is available |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|-bgcolor ="#EEFFFF" |
|||
! bgcolor="#D0E7FF" align="center" | GaAs |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|{{rl|ICP Etching Recipes|AlGaAs Etch (Panasonic 1)}} |
|||
|{{rl|ICP Etching Recipes|GaAs Etch (Panasonic 2)}} |
|||
|{{rl|ICP Etching Recipes|GaAs Etch (Unaxis VLR)}} |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|- |
|- |
||
|R4 |
|||
! bgcolor="#D0E7FF" align="center" | AlGaAs |
|||
| colspan="11" |Process has a documented procedure with regular (≥4x per year) data '''or''' lookahead/in-situ control available |
|||
| |
|||
| |
|||
| |
|||
|{{rl|RIE Etching Recipes|AlGaAs Etch (RIE 5)}} |
|||
| |
|||
|{{rl|ICP Etching Recipes|AlGaAs Etch (Panasonic 1)}} |
|||
| |
|||
|{{rl|ICP Etching Recipes|AlGaAs Etch (Unaxis VLR)}} |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|-bgcolor ="#EEFFFF" |
|||
! bgcolor="#D0E7FF" align="center" | InGaAlAs |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|- |
|- |
||
|R5 |
|||
! bgcolor="#D0E7FF" align="center" | InGaAsP |
|||
| colspan="11" |Process has a documented procedure with regular (≥4x per year) data '''and''' lookahead/in-situ control available |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|-bgcolor ="#EEFFFF" |
|||
! bgcolor="#D0E7FF" align="center" | InP |
|||
| |
|||
| {{rl|RIE Etching Recipes|InP Etch (MRC)}} |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| {{rl|ICP Etching Recipes|InP Etch (Unaxis VLR)}} |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|- |
|||
! bgcolor="#D0E7FF" align="center" | GaN |
|||
| |
|||
| |
|||
| |
|||
|{{rl|RIE Etching Recipes|GaN Etch (RIE 5)}} |
|||
| |
|||
| {{rl|ICP Etching Recipes|GaN Etch (Panasonic 1)}} |
|||
| |
|||
| {{rl|ICP Etching Recipes|GaN Etch (Unaxis VLR)}} |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|-bgcolor ="#EEFFFF" |
|||
! bgcolor="#D0E7FF" align="center" | AlGaN |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|- |
|||
! bgcolor="#D0E7FF" align="center" | AlN |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|-bgcolor ="#EEFFFF" |
|||
! bgcolor="#D0E7FF" align="center" | GaN |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|- |
|||
! bgcolor="#D0E7FF" align="center" | AlGaN |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|-bgcolor ="#EEFFFF" |
|||
! bgcolor="#D0E7FF" align="center" | AlN |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|- |
|||
! bgcolor="#D0E7FF" align="center" | GaSb |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|-bgcolor ="#EEFFFF" |
|||
! bgcolor="#D0E7FF" align="center" | CdZnTe |
|||
| |
|||
| {{rl|RIE Etching Recipes|CdZnTe Etch (RIE 2)}} |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|- |
|||
! bgcolor="#D0E7FF" align="center" | ZnSe |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|-bgcolor ="#EEFFFF" |
|||
! bgcolor="#D0E7FF" align="center" | Si |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| {{rl|ICP Etching Recipes|Si Etch (PlasmaTherm/Bosch Etch)}} |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| {{rl|Other Dry Etching Recipes|Other Dry Etch (XeF2 Etcher)}} |
|||
|- |
|||
! bgcolor="#D0E7FF" align="center" | SiC |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|-bgcolor ="#EEFFFF" |
|||
! bgcolor="#D0E7FF" align="center" | Sapphire |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|- |
|- |
||
|R6 |
|||
! bgcolor="#D0E7FF" align="center" | '''Material''' |
|||
| colspan="11" |Process has a documented procedure, regular ( ≥4x per year) data, and control charts & limits available |
|||
| bgcolor="#DAF1FF" | [[RIE 1 (Custom)|RIE 1<br>(Custom)]] |
|||
| bgcolor="#DAF1FF" | [[RIE 2 (MRC)|RIE 2<br> (MRC)]] |
|||
| bgcolor="#DAF1FF" | [[RIE 3 (MRC)|RIE 3<br> (MRC)]] |
|||
| bgcolor="#DAF1FF" | [[RIE 5 (PlasmaTherm)|RIE 5<br>(PlasmaTherm)]] |
|||
| bgcolor="#DAF1FF" | [[Si Deep RIE (PlasmaTherm/Bosch Etch)|Si Deep RIE<br>(PlasmaTherm/Bosch Etch)]] |
|||
| bgcolor="#DAF1FF" | [[ICP Etch 1 (Panasonic E626I)|ICP Etch 1<br>(Panasonic E626I)]] |
|||
| bgcolor="#DAF1FF" | [[ICP Etch 2 (Panasonic E640)|ICP Etch 2<br>(Panasonic E640)]] |
|||
| bgcolor="#DAF1FF" | [[ICP-Etch (Unaxis VLR)|ICP-Etch<br>(Unaxis VLR)]] |
|||
| bgcolor="#DAF1FF" | [[Ashers (Technics PEII)|Ashers<br>(Technics PEII)]] |
|||
| bgcolor="#DAF1FF" | [[Plasma Clean (Gasonics 2000)|Plasma Clean<br>(Gasonics 2000)]] |
|||
| bgcolor="#DAF1FF" | [[UV Ozone Reactor]] |
|||
| bgcolor="#DAF1FF" | [[Plasma Activation (EVG 810)|Plasma Activation<br>(EVG 810)]] |
|||
| bgcolor="#DAF1FF" | [[XeF2 Etch (Xetch)|XeF2 Etch<br>(Xetch)]] |
|||
|} |
|} |
||
[[Category:Processing]] |
Latest revision as of 20:48, 27 November 2024
Process Control Data
See above linked page for process control data (dep rate/stress etc. over time), for a selection of often-used dry etches
Dry Etching Tools/Materials Table
The Key/Legend for this table's A...R6
values is at the bottom of the page.
Process Ranking Table
Processes in the table above are ranked by their "Process Maturity Level" as follows:
Process Level | Description of Process Level Ranking | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
A | Process Allowed and materials available but never done | ||||||||||
R1 | Process has been run at least once | ||||||||||
R2 | Process has been run and/or procedure is documented or/and data available | ||||||||||
R3 | Process has been run, procedure is documented, and data is available | ||||||||||
R4 | Process has a documented procedure with regular (≥4x per year) data or lookahead/in-situ control available | ||||||||||
R5 | Process has a documented procedure with regular (≥4x per year) data and lookahead/in-situ control available | ||||||||||
R6 | Process has a documented procedure, regular ( ≥4x per year) data, and control charts & limits available |