Line 2: Line 2:
|picture=microscopes.jpg
|picture=microscopes.jpg
|type = Inspection, Test and Characterization
|type = Inspection, Test and Characterization
|super= Demis John
|super= Demis D. John
|location=Bay 3, 6 & 7
|location=Bay 3, 6 & 7
|description = Optical Microscopes
|description = Optical Microscopes
Line 8: Line 8:
}}
}}


== Procedures & Tools ==
==Procedures & Tools==
Most General-Use Microscopes do not require formal training - please see the pages below for specifics.

===[[UCSB NanoFab Microscope Training|'''Microscope Training Guide''']]===
===[[UCSB NanoFab Microscope Training|'''Microscope Training Guide''']]===
This guide is for '''self-training''' on the specified general-use microscopes specified below.
Use the guide linked above for general usage info & the many advanced features available on most of our microscopes. New users are encouraged to read this, and also request in-person training by [[Demis D. John|Demis]].


This guide explains general usage info & the many advanced features available on most of our microscopes. New users are encouraged to read this, and optionally request in-person training by [[Demis D. John|Demis]].
=== Image Analysis Software ===

Includes topics like:

*Basic usage
*Preventing a crash
*Bright-Field/Dark Field
*How to dis/enable DIC/Nomarskiimaging

<ins>'''DO NOT TURN MICROSCOPE OBJECTIVES BY HAND''' for motorized microscopes! Most of our scopes have motorized objective turrets, use the electronic buttons instead.</ins>

===Image Analysis Software===
Many of our microscopes have cameras and software for image capture. If you know the ''microscope and objective'' used for acquiring a photo, you can make calibrated measurements on the photos at your own desktop using the following software:
Many of our microscopes have cameras and software for image capture. If you know the ''microscope and objective'' used for acquiring a photo, you can make calibrated measurements on the photos at your own desktop using the following software:

*[https://www.amscope.com/software-download AmScope Software] - microscope image analysis software
*[https://www.amscope.com/software-download AmScope Software] - free microscope image analysis software
**[[Measurements and Imaging with Amscope Camera - Quickstart Usage Guide]]
**AmScope Calibration File containing calibrations for all NanoFab microscopes: [https://wiki.nanotech.ucsb.edu/wiki/Images/uploads/2020/AmScopeCalsAll.magn Download Here]
**AmScope Calibration File containing calibrations for all NanoFab microscopes: [https://wiki.nanotech.ucsb.edu/wiki/Images/uploads/2020/AmScopeCalsAll.magn Download Here]
**Also available on '''''Nanofiles-SFTP / Manuals / Amscope'''''
**Also available on '''''Nanofiles-SFTP / Manuals / Amscope'''''
Line 22: Line 37:
**There are many [https://imagej.net/Category:Plugins other useful plugins], for particle counting, [https://stackoverflow.com/questions/6230353/how-to-create-gif-animation-from-a-stack-of-jpgs/37193012#37193012 creating animations] etc.
**There are many [https://imagej.net/Category:Plugins other useful plugins], for particle counting, [https://stackoverflow.com/questions/6230353/how-to-create-gif-animation-from-a-stack-of-jpgs/37193012#37193012 creating animations] etc.


==General-Use Microscopes==
==Nikon==
'''''Self-Train:''' The following microscopes are self-train to use.''
The Nikon scopes have 3rd party cameras that are connected to computers via AM Scope software which allows users to digitally capture images through the microscope and make calibrated measurements.
''Please study the [[UCSB NanoFab Microscope Training|'''Microscope Training Guide''']] for training.''
Contact the [[Demis D. John|supervisor]] if you would like a hands-on training or have questions.


===Microscope #2: Nikon Optiphot 200 (Bay 7)===
===Microscope #2: Nikon Optiphot 200 (Bay 2)===


*Location: Dry Etch Bay 2
*Trinocular: Ocular Binoc. + Camera (Simultaneous)
*Trinocular: Ocular Binoc. + Camera (Simultaneous)
*Objectives: 5x, 10x, 20x, 50x, 100x, 150x
*Objectives: 5x, 10x, 20x, 50x, 100x, 150x
Line 34: Line 54:
**DIC only available on 100x and 150x mags due to image quality reduction at low mags due to DIC prisms which were removed for low mags.
**DIC only available on 100x and 150x mags due to image quality reduction at low mags due to DIC prisms which were removed for low mags.
*Top Reflected Illumination (Episcopic)
*Top Reflected Illumination (Episcopic)
*AMScope 14MP Cameras with calibrated software for measurements. Software available for desktop measurements. [https://www.amscope.com/software-download Link here].
*AMScope 14MP Cameras (Model MU1400B) with calibrated software for measurements. Free Software available for calibrated measurements. [[Microscopes#Image Analysis Software|See above]] for software & calibration file link.


===Microscope #3: Nikon Eclipse L200 (Bay 6)===
===Microscope #3: Nikon Eclipse L200 (Bay 6)===


*Location: Lithography yellow area, Bay 6
*[https://wiki.nanotech.ucsb.edu/wiki/images/8/80/Nikon-Microscope-Manual.pdf Manual for Nikon Eclipse L200D]
*[https://wiki.nanotech.ucsb.edu/wiki/images/8/80/Nikon-Microscope-Manual.pdf Manual for Nikon Eclipse L200D]
*Trinocular: Binoc. + Camera (Mutually Exclusive)
*Trinocular: Binoc. + Camera (Mutually Exclusive)
Line 45: Line 66:
*Differential Interference Contrast (DIC/Nomarski)
*Differential Interference Contrast (DIC/Nomarski)
*Top Reflected Illumination (Episcopic)
*Top Reflected Illumination (Episcopic)
*AMScope 14MP Cameras with calibrated software for measurements. Software available for desktop measurements. [https://www.amscope.com/software-download Link here].
*AMScope 14MP Cameras (Model MU1400B) with calibrated software for measurements. Free Software available for calibrated measurements. [[Microscopes#Image Analysis Software|See above]] for software & calibration file link.


===Microscope #4: Nikon Eclipse L200D (Bay 6)===
===Microscope #4: Nikon Eclipse L200D (Bay 6)===


*Location: Lithography yellow area, Bay 6
*Trinocular: Binoc. + Camera (Mutually Exclusive)
*Trinocular: Binoc. + Camera (Mutually Exclusive)
*Objectives: 5x, 10x, 20x, 50x, 100x, 150x
*Objectives: 5x, 10x, 20x, 50x, 100x, 150x
Line 55: Line 77:
*Differential Interference Contrast (DIC/Nomarski)
*Differential Interference Contrast (DIC/Nomarski)
*Top Reflected (Episcopic) & Bottom Transmission (Diascopic) Illumination
*Top Reflected (Episcopic) & Bottom Transmission (Diascopic) Illumination
*AMScope 14MP Cameras with calibrated software for measurements. Software available for desktop measurements. [https://www.amscope.com/software-download Link here].
*AMScope 14MP Cameras (Model MU1400B) with calibrated software for measurements. Free Software available for calibrated measurements. [[Microscopes#Image Analysis Software|See above]] for software & calibration file link.

==Olympus==

The lab has two general purpose Olympus microscopes, and two specialized microscopes that require training to use, although both of these can also be used for general imaging.
[[File:Microscope 01 Olympus BHMJL crop.png|alt=Photo of Microscope #01 in the Characterization lab, Room 1111|thumb|200x200px|Microscope #01 in the Characterization lab, Room 1111]]

===Microscope #1: Olympus BHMJL (Char. Lab, Room 1111)===

*Trinocular: Ocular Binoc. + Camera (Exclusive)
*LED Illuminator, Variable
*Objectives: ''10x, 20x, 50x, 100x''
*Bright/Dark Field
*Top Reflected (Episcopic) & Bottom Transmission (Diascopic) Illumination
*AMScope 14MP Cameras with calibrated software for measurements. Software available for offline measurements: [https://www.amscope.com/software-download Link here].
*User Manual: [https://wiki.nanotech.ucsb.edu/wiki/index.php/File:Olympus_-_BHM_Microscope_-_Instruction_Manual.pdf Olympus BHM Microscopes - Instruction Manual (PDF)]


===Microscope #5: [[Fluorescence Microscope (Olympus MX51)|Fluorescence Microscope: Olympus MX51 (Bay 6)]]===
===Microscope #5: [[Fluorescence Microscope (Olympus MX51)|Fluorescence Microscope: Olympus MX51 (Bay 6)]]===


*Location: Lithography yellow area, Bay 6
*See the wiki page for the [[Fluorescence Microscope (Olympus MX51)|Olympus MX51]] for full details
*See the wiki page for the [[Fluorescence Microscope (Olympus MX51)|Olympus MX51]] for full details
*Trinocular: Binoc. + Camera (Simultaneous)
*Trinocular: Binoc. + Camera (Simultaneous)
Line 86: Line 94:
*Three Fluorescence Filters (requires training, see main tool page for specs.)
*Three Fluorescence Filters (requires training, see main tool page for specs.)


[[File:Microscope 01 Olympus BHMJL crop.png|alt=Photo of Microscope #01 in the Characterization lab, Room 1111|thumb|200x200px|Microscope #01]]
===Microscope #6: [[Deep UV Optical Microscope (Olympus)|DUV Microscope: Olympus MX61A-DUV (Bay 7)]]===

===Microscope #1: Olympus BHMJL (Room 1111)===

*Location: Back-End Lab, Room 1111
*Trinocular: Ocular Binoc. + Camera (Exclusive)
*LED Illuminator, Variable
*Objectives: ''10x, 20x, 50x, 100x''
*Bright/Dark Field
*Top Reflected (Episcopic) & Bottom Transmission (Diascopic) Illumination
*AMScope 14MP Cameras (Model MU1400B) with calibrated software for measurements. Free Software available for calibrated measurements. [[Microscopes#Image Analysis Software|See above]] for software & calibration file link.

===Microscope #8: AmScope Wide Field of View Stereoscope (Bay 4)===
[[File:Amscope Stereoscope Photo.jpg|alt=photo of the Amscope Sterescope microscope in bay 4|thumb|250x250px|Microscope #8: Amscope Stereoscope]]

*Location: Metrology, Bay 4
*Integrated camera for taking large field of view pictures. 
*The field of view is about 25mm in '''Y''' and larger in '''X''' at the lowest magnification. 
*Nanofiles Sync for file transfer: FTP folder name "''amscope''". 
*AmScope software on the laptop to use the camera.
*On the side of the main scope there is a small lever that is used to divert the image from the right eyepiece to the camera for imaging, the left eyepiece remains open for viewing at all times. 

==Microscopes Requiring Training==
''The following microscopes require training from the supervisor. Click on the appropriate tool page to see the supervisor info.''

===Microscope #6: [[Deep UV Optical Microscope (Olympus)|DUV Microscope: Olympus MX61A-DUV (Bay 4)]]===
Please see the main tool page for detailed info on this microscope: [[Deep UV Optical Microscope (Olympus)]]
Please see the main tool page for detailed info on this microscope: [[Deep UV Optical Microscope (Olympus)]]
YOU ARE REQUIRED TO GET TRAINED on this tool before you are allowed to use it! Please contact the Tool Owner to get training.
YOU ARE REQUIRED TO GET TRAINED on this tool before you are allowed to use it! Please contact the Tool Owner to get training.


'''DUV Camera is non-operational and unable to be repaired. Visible camera is still functional. 2022-02'''

*Location: Metrology, Bay 4
*Motorized Stage + Objective Turret
*Motorized Stage + Objective Turret
*Trinocular: Binoc. + Camera (Simultaneous)
*Trinocular: Binoc. + Camera (Simultaneous)
Line 100: Line 136:
**DUV-100x sub-micron imaging/measurement
**DUV-100x sub-micron imaging/measurement


==[[Laser Scanning Confocal M-scope (Olympus LEXT)|Olympus LEXT Confocal Microscope (Bay 4)]]==
===Microscope #7: [[Digital Microscope (Olympus DSX1000)|Olympus DSX1000 Digital Microscope (Bay 4)]]===
Please see the main tool page for detailed info on this microscope, click the link above.
YOU ARE REQUIRED TO GET TRAINED on this tool before you are allowed to use it! Please contact the Tool Supervisor to get training.

*Location: Metrology, Bay 4
*Motorized Stage + Optics
*Optical magnification via motorized optics, increases mag beyond objective’s value.
*Manual switch between 2 objectives.
*Digital Viewing via Computer
*Objectives: High-Res.: 5x, 50x // Long-Distance + Angled Viewing: 10x, 40x
*Imaging Modes:
**Bright Field
**Dark Field
**DIC/Nomarski
**Oblique Ilumination w/ variable illumination angle
**Polarized imaging w/ variable polarization
*Native Olympus Software control & Camera
**Calibrated measurements (calibrations locked)
**Z (focus) measurement via motorized stage height
**3D height Meas (for taller features)
**Rapidly capture multiple imaging modes
**Offline Analysis Software available for free
*Tilted Imaging capabilities, for deep (> few micron) features.

===[[Laser Scanning Confocal M-scope (Olympus LEXT)|Olympus LEXT Confocal Microscope (Bay 4)]]===
See the main tool page for complete info: [[Laser Scanning Confocal M-scope (Olympus LEXT)]]
See the main tool page for complete info: [[Laser Scanning Confocal M-scope (Olympus LEXT)]]
YOU ARE REQUIRED TO GET TRAINED on this tool before you are allowed to use it! Please contact the Tool Owner to get training.
YOU ARE REQUIRED TO GET TRAINED on this tool before you are allowed to use it! Please contact the Tool Owner to get training.


*Location: Metrology, Bay 4
*Motorized stage + Objective Turret
*Motorized stage + Objective Turret
*100mm wafer stage
*100mm wafer stage
Line 113: Line 174:
**Surface roughness estimations (large roughness)
**Surface roughness estimations (large roughness)
**Thin-Film Film-Thickness Measurements (thicker films)
**Thin-Film Film-Thickness Measurements (thicker films)

===[[Filmetrics F40-UV Microscope-Mounted|Filmetrics F40-UV / Olympus BHMJL (Bay 4)]]===

*Location: Metrology, Bay 4
*Very simple, manual microscope.
*Has spectroscopic reflectometer attached for thin-film measurements in small (<100µm) area.
*See the tool page for Training on the Filmetrics Thin-Film Measurement tool.


==Procedures & Documentation==
==Procedures & Documentation==

Latest revision as of 21:24, 11 June 2026

Microscopes
Tool Type Inspection, Test and Characterization
Location Bay 3, 6 & 7
Supervisor Demis D. John
Supervisor Phone (805) 893-5934
Supervisor E-Mail demis@ucsb.edu
Description Optical Microscopes
Manufacturer Nikon & Olympus



Procedures & Tools

Most General-Use Microscopes do not require formal training - please see the pages below for specifics.

Microscope Training Guide

This guide is for self-training on the specified general-use microscopes specified below.

This guide explains general usage info & the many advanced features available on most of our microscopes. New users are encouraged to read this, and optionally request in-person training by Demis.

Includes topics like:

  • Basic usage
  • Preventing a crash
  • Bright-Field/Dark Field
  • How to dis/enable DIC/Nomarskiimaging
DO NOT TURN MICROSCOPE OBJECTIVES BY HAND for motorized microscopes!  Most of our scopes have motorized objective turrets, use the electronic buttons instead.

Image Analysis Software

Many of our microscopes have cameras and software for image capture. If you know the microscope and objective used for acquiring a photo, you can make calibrated measurements on the photos at your own desktop using the following software:

General-Use Microscopes

Self-Train: The following microscopes are self-train to use.

Please study the Microscope Training Guide for training.

Contact the supervisor if you would like a hands-on training or have questions.

Microscope #2: Nikon Optiphot 200 (Bay 2)

  • Location: Dry Etch Bay 2
  • Trinocular: Ocular Binoc. + Camera (Simultaneous)
  • Objectives: 5x, 10x, 20x, 50x, 100x, 150x
  • Filters: Green, ND
  • Bright/Dark Field
  • Differential Interference Contrast (DIC/Nomarski)
    • DIC only available on 100x and 150x mags due to image quality reduction at low mags due to DIC prisms which were removed for low mags.
  • Top Reflected Illumination (Episcopic)
  • AMScope 14MP Cameras (Model MU1400B) with calibrated software for measurements. Free Software available for calibrated measurements. See above for software & calibration file link.

Microscope #3: Nikon Eclipse L200 (Bay 6)

  • Location: Lithography yellow area, Bay 6
  • Manual for Nikon Eclipse L200D
  • Trinocular: Binoc. + Camera (Mutually Exclusive)
  • Objectives: 5x, 10x, 20x, 50x, 100x, 150x
  • Filters: Green, ND
  • Bright/Dark Field
  • Differential Interference Contrast (DIC/Nomarski)
  • Top Reflected Illumination (Episcopic)
  • AMScope 14MP Cameras (Model MU1400B) with calibrated software for measurements. Free Software available for calibrated measurements. See above for software & calibration file link.

Microscope #4: Nikon Eclipse L200D (Bay 6)

  • Location: Lithography yellow area, Bay 6
  • Trinocular: Binoc. + Camera (Mutually Exclusive)
  • Objectives: 5x, 10x, 20x, 50x, 100x, 150x
  • Filters: Green, ND
  • Bright/Dark Field
  • Differential Interference Contrast (DIC/Nomarski)
  • Top Reflected (Episcopic) & Bottom Transmission (Diascopic) Illumination
  • AMScope 14MP Cameras (Model MU1400B) with calibrated software for measurements. Free Software available for calibrated measurements. See above for software & calibration file link.

Microscope #5: Fluorescence Microscope: Olympus MX51 (Bay 6)

  • Location: Lithography yellow area, Bay 6
  • See the wiki page for the Olympus MX51 for full details
  • Trinocular: Binoc. + Camera (Simultaneous)
  • Native Olympus Stream Software:
    • Photo/video capture
    • Calibrated measurement (calibrations locked)
  • Objectives: 5x, 10x, 20x, 50x, 100x, 150x
  • Filters: Green, ND
  • Bright/Dark Field
  • Differential Interference Contrast (DIC/Nomarski)
  • Top (Episcopic) & Bottom (Diascopic) Illumination
  • Three Fluorescence Filters (requires training, see main tool page for specs.)
Photo of Microscope #01 in the Characterization lab, Room 1111
Microscope #01

Microscope #1: Olympus BHMJL (Room 1111)

  • Location: Back-End Lab, Room 1111
  • Trinocular: Ocular Binoc. + Camera (Exclusive)
  • LED Illuminator, Variable
  • Objectives: 10x, 20x, 50x, 100x
  • Bright/Dark Field
  • Top Reflected (Episcopic) & Bottom Transmission (Diascopic) Illumination
  • AMScope 14MP Cameras (Model MU1400B) with calibrated software for measurements. Free Software available for calibrated measurements. See above for software & calibration file link.

Microscope #8: AmScope Wide Field of View Stereoscope (Bay 4)

photo of the Amscope Sterescope microscope in bay 4
Microscope #8: Amscope Stereoscope
  • Location: Metrology, Bay 4
  • Integrated camera for taking large field of view pictures. 
  • The field of view is about 25mm in Y and larger in X at the lowest magnification. 
  • Nanofiles Sync for file transfer: FTP folder name "amscope". 
  • AmScope software on the laptop to use the camera.
  • On the side of the main scope there is a small lever that is used to divert the image from the right eyepiece to the camera for imaging, the left eyepiece remains open for viewing at all times. 

Microscopes Requiring Training

The following microscopes require training from the supervisor. Click on the appropriate tool page to see the supervisor info.

Microscope #6: DUV Microscope: Olympus MX61A-DUV (Bay 4)

Please see the main tool page for detailed info on this microscope: Deep UV Optical Microscope (Olympus)

YOU ARE REQUIRED TO GET TRAINED on this tool before you are allowed to use it! Please contact the Tool Owner to get training.
DUV Camera is non-operational and unable to be repaired. Visible camera is still functional. 2022-02
  • Location: Metrology, Bay 4
  • Motorized Stage + Objective Turret
  • Trinocular: Binoc. + Camera (Simultaneous)
  • Objectives: 5x, 10x, 20, 50x, 100x, DUV-100x
  • Filters: to be added
  • Native Olympus MX61 Software control & Camera
    • Calibrated measurements (calibrations locked)
    • Z (focus) measurement via motorized stage height
  • Deep-UV Light source + DUV Camera
    • DUV-100x sub-micron imaging/measurement

Microscope #7: Olympus DSX1000 Digital Microscope (Bay 4)

Please see the main tool page for detailed info on this microscope, click the link above.

YOU ARE REQUIRED TO GET TRAINED on this tool before you are allowed to use it! Please contact the Tool Supervisor to get training.
  • Location: Metrology, Bay 4
  • Motorized Stage + Optics
  • Optical magnification via motorized optics, increases mag beyond objective’s value.
  • Manual switch between 2 objectives.
  • Digital Viewing via Computer
  • Objectives: High-Res.: 5x, 50x // Long-Distance + Angled Viewing: 10x, 40x
  • Imaging Modes:
    • Bright Field
    • Dark Field
    • DIC/Nomarski
    • Oblique Ilumination w/ variable illumination angle
    • Polarized imaging w/ variable polarization
  • Native Olympus Software control & Camera
    • Calibrated measurements (calibrations locked)
    • Z (focus) measurement via motorized stage height
    • 3D height Meas (for taller features)
    • Rapidly capture multiple imaging modes
    • Offline Analysis Software available for free
  • Tilted Imaging capabilities, for deep (> few micron) features.

Olympus LEXT Confocal Microscope (Bay 4)

See the main tool page for complete info: Laser Scanning Confocal M-scope (Olympus LEXT)

YOU ARE REQUIRED TO GET TRAINED on this tool before you are allowed to use it! Please contact the Tool Owner to get training.
  • Location: Metrology, Bay 4
  • Motorized stage + Objective Turret
  • 100mm wafer stage
  • Native Olympus OLS2000 Software & Built-In Camera:
    • Calibrated measurement (calibrations locked)
    • Image stitching capabilities
  • 3D Laser-Scanning Confocal Microscopy capability:
    • 3D Topographical measurement (optical profilometry)
    • Surface roughness estimations (large roughness)
    • Thin-Film Film-Thickness Measurements (thicker films)

Filmetrics F40-UV / Olympus BHMJL (Bay 4)

  • Location: Metrology, Bay 4
  • Very simple, manual microscope.
  • Has spectroscopic reflectometer attached for thin-film measurements in small (<100µm) area.
  • See the tool page for Training on the Filmetrics Thin-Film Measurement tool.

Procedures & Documentation