{{tool2|{{PAGENAME}} |
||
|picture=KLA.jpg |
|picture=KLA.jpg |
||
|type = Inspection, Test and Characterization |
|type = Inspection, Test and Characterization |
||
|super= Biljana Stamenic |
|super= Biljana Stamenic |
||
|super2= Don Freeborn |
|||
|location=Bay 5 |
|location=Bay 5 |
||
|description = |
|description = Surface Analysis |
||
|manufacturer = Tencor |
|manufacturer = KLA/Tencor |
||
|materials = |
|materials = |
||
|toolid= |
|toolid= |
||
}} |
}} |
||
=About= |
==About== |
||
This system uses a laser-based scattering method to count size and distribution of particles (or other scattering defects) on a flat wafer surface. |
This system uses a laser-based scattering method to count size and distribution of particles (or other scattering defects) on a flat wafer surface. |
||
It can scan wafers in size from 4 to 8 inches. Piece-parts are more difficult but can be scanned with a custom recipe. |
|||
| ⚫ | |||
| ⚫ | |||
4-inch wafers are the most standard size to measure. |
|||
For measuring very low particle counts accurately, purchase "low particle count" (LPC) wafers from a Silicon wafer vendor, and keep the wafers in the case and clean at all times until use. |
|||
| ⚫ | |||
===Operating Procedures=== |
|||
*[https://wiki.nanofab.ucsb.edu/w/images/2/29/Wafer_Particle_Count-Process_Traveler.pdf Wafer Scanning Instructions] |
|||
**''This is the procedure Staff uses to calibrate particle counts on our deposition tools. After the scan is complete you need to press ENTER on a small laptop. The Data will be saved on: Desktop/Local Disk(C)/Users/Public/Public Documentation] The data will be saved as a photo.'' |
|||
*[[Surfscan SOP for small substrates]] (''You must water-mount your small sample or wafer (2inch or 3 inch) to a carrier wafer)'' |
|||
*[[Surfscan SOP for 4inch wafers]] |
|||
*[[Surfscan SOP for 6inch wafers]] |
|||
*[[Surfscan SOP for 8inch wafers]] |
|||
* [[Wafer scanning process traveler|Wafer Particle Count - Process Traveler]] |
|||
**'' Very detailed instructions |
|||
===Other Documentation=== |
|||
| ⚫ | |||
**''For detailed measurement info, it is highly recommended that you read the manual.'' |
|||
*[[Glossary]] |
|||
*[[Surfscan Errors and Workarounds|Common Errors & Workarounds]] |
|||
==Examples== |
|||
{| class="wikitable" |
|||
|+A low-particle 4-inch wafer example: |
|||
!Gain 4: Small Particles |
|||
(0.160µm – 1.60µm) |
|||
!Gain 2: Large Particles |
|||
(1.60µm – 28.0µm) |
|||
|- |
|||
|[[File:Surfscan Low-Particle Example - G4.png|frameless|200x200px]] |
|||
|[[File:Surfscan Low-Particle Example - G2.png|frameless|200x200px]] |
|||
|} |
|||
{| class="wikitable" |
|||
|+A high-particle 4-inch wafer example: |
|||
!Gain 4: Small Particles |
|||
(0.160µm – 1.60µm) |
|||
!Gain 2: Large Particles |
|||
(1.60µm – 28.0µm) |
|||
|- |
|||
|[[File:Surfscan - 230113A7 Gain4 high particles.jpg|frameless|199x199px]] |
|||
|[[File:Surfscan 230113A7G2 after low particles.jpg|frameless|195x195px]] |
|||
|} |
|||
Latest revision as of 23:04, 20 November 2024
| ||||||||||||||||||||||||||
About
This system uses a laser-based scattering method to count size and distribution of particles (or other scattering defects) on a flat wafer surface.
It can scan wafers in size from 4 to 8 inches. Piece-parts are more difficult but can be scanned with a custom recipe.
4-inch wafers are the most standard size to measure.
For measuring very low particle counts accurately, purchase "low particle count" (LPC) wafers from a Silicon wafer vendor, and keep the wafers in the case and clean at all times until use.
Documentation
Operating Procedures
- Wafer Scanning Instructions
- This is the procedure Staff uses to calibrate particle counts on our deposition tools. After the scan is complete you need to press ENTER on a small laptop. The Data will be saved on: Desktop/Local Disk(C)/Users/Public/Public Documentation] The data will be saved as a photo.
- Surfscan SOP for small substrates (You must water-mount your small sample or wafer (2inch or 3 inch) to a carrier wafer)
- Wafer Particle Count - Process Traveler
- Very detailed instructions
Other Documentation
- Operations Manual
- For detailed measurement info, it is highly recommended that you read the manual.
Examples
| Gain 4: Small Particles
(0.160µm – 1.60µm) |
Gain 2: Large Particles
(1.60µm – 28.0µm) |
|---|---|
| Gain 4: Small Particles
(0.160µm – 1.60µm) |
Gain 2: Large Particles
(1.60µm – 28.0µm) |
|---|---|