User contributions
Jump to navigation
Jump to search
- 10:03, 30 April 2018 diff hist -52 Vapor HF Etch link to Vapor HF recipes
- 15:01, 27 April 2018 diff hist 0 m Template:Announcements rearrange, newest on top
- 15:00, 27 April 2018 diff hist +88 Template:Announcements RIE5 sicl4 update
- 14:58, 27 April 2018 diff hist +224 m Template:Announcements moved isntructions to bottom of page
- 16:48, 26 April 2018 diff hist -15 Template:Announcements pecvd 2 title
- 16:48, 26 April 2018 diff hist +52 Template:Announcements pecvd2 update
- 16:15, 26 April 2018 diff hist +57 Template:Announcements rie5 sicl4 down
- 12:50, 25 April 2018 diff hist -80 Template:Announcements stepper 2 up
- 16:55, 24 April 2018 diff hist -377 Template:Announcements deleted ADT
- 16:54, 24 April 2018 diff hist +267 m Editing Tutorials →Basic Editing: disclaminer about antiquated code. Tag: Visual edit
- 16:45, 24 April 2018 diff hist +66 Template:Announcements stepper2 update
- 12:51, 24 April 2018 diff hist -26 Template:Announcements stepper #2 down, pecvd update, deleted EB4
- 11:11, 18 April 2018 diff hist +147 m Frequently Asked Questions →I need help using a tool, where do I get help?: when in doubt, ask for help Tag: Visual edit
- 10:48, 18 April 2018 diff hist +14 m Frequently Asked Questions →I need help using a tool, where do I get help?: link to tool list Tag: Visual edit
- 10:48, 18 April 2018 diff hist +874 Frequently Asked Questions how to find equipment manuals etc. Tag: Visual edit
- 13:01, 17 April 2018 diff hist +385 CDE ResMap Quick-Start instructions photo of measurement locations current Tag: Visual edit
- 12:59, 17 April 2018 diff hist +33 N File:CDE ResMap Quarter Wafer meas location - 800px annot quarterwf.png current
- 12:57, 17 April 2018 diff hist +30 N File:CDE ResMap Full Wafer meas location - IMG 0112 - 800px annot.png current
- 12:55, 17 April 2018 diff hist +946 N CDE ResMap Quick-Start instructions initial instrucitons Tag: Visual edit
- 12:42, 17 April 2018 diff hist +66 Resistivity Mapper (CDE RESMAP) link to quick-start instructions page Tag: Visual edit
- 13:33, 16 April 2018 diff hist +37 Sputtering Recipes →Sputter 4 (AJA ATC 2200-V): added Power Source column Tag: Visual edit
- 13:32, 16 April 2018 diff hist +223 Sputtering Recipes →Sputter 5 (Lesker AXXIS): link to SUM page for installed targets Tag: Visual edit
- 13:31, 16 April 2018 diff hist +128 Sputtering Recipes →Sputter 5 (Lesker AXXIS): added Al2O3 and Power SOurce column Tag: Visual edit
- 13:26, 16 April 2018 diff hist -51 Sputtering Recipes update comment indicating incorrect title Tag: Visual edit: Switched
- 10:04, 16 April 2018 diff hist +65 Wet Etching Recipes →The Master Table of Wet Etching (Include All Materials): corrected "BHF 49%" --> "BHF" Tag: Visual edit
- 10:00, 16 April 2018 diff hist +461 Wet Etching Recipes →References: link to transene chemical compatibility chart Tag: Visual edit
- 17:53, 13 April 2018 diff hist +578 Template:Announcements PECVD#2 retraining, 90°C Hotplate down
- 10:11, 13 April 2018 diff hist +237 Chemical List - OLD 2018-09-05 →Lithography Chemicals: link to Recipes > Litho > Datasheets Tag: Visual edit
- 07:10, 13 April 2018 diff hist +3 m Tool List minor description update Tag: Visual edit
- 07:08, 13 April 2018 diff hist 0 MediaWiki:Sidebar reorder chemicals lower
- 07:07, 13 April 2018 diff hist +12 MediaWiki:Sidebar MSDS --> "Chemicals + MSDS"
- 07:06, 13 April 2018 diff hist +347 Chemical List - OLD 2018-09-05 updated info Tag: Visual edit
- 07:01, 13 April 2018 diff hist +108 Tool List →Wet Processing: link to Chemical List page Tag: Visual edit
- 13:48, 12 April 2018 diff hist -257 Template:Announcements deleted blueM & ICP2 up posts
- 13:48, 12 April 2018 diff hist +292 Template:Announcements rie5 down 4/19
- 13:26, 9 April 2018 diff hist +45 Wet Etching Recipes →The Master Table of Wet Etching (Include All Materials): HF selective to PR Tag: Visual edit
- 13:25, 9 April 2018 diff hist -143 Wet Etching Recipes →The Master Table of Wet Etching (Include All Materials): removed duplicate row Tag: Visual edit
- 13:09, 9 April 2018 diff hist +134 Calculators + Utilities →Scripts + Programs: put analysis prgs at top Tag: Visual edit
- 12:55, 9 April 2018 diff hist +204 Calculators + Utilities link to ProFilmOnline Tag: Visual edit
- 12:41, 9 April 2018 diff hist +51 Calculators + Utilities move nk.py to "Scripts" section Tag: Visual edit
- 12:40, 9 April 2018 diff hist +175 Calculators + Utilities add http://www.lelandstanfordjunior.com Tag: Visual edit
- 12:37, 9 April 2018 diff hist +21 Tube Furnace (Tystar 8300) →About: low-temp ox on tube 1 Tag: Visual edit
- 12:36, 9 April 2018 diff hist +12 m Tube Furnace (Tystar 8300) →About: minor rewording Tag: Visual edit
- 12:33, 9 April 2018 diff hist +1 Template:Tool 300x350px max
- 12:32, 9 April 2018 diff hist -1 Template:Tool image --> file syntax
- 12:29, 9 April 2018 diff hist +4 Template:Tool set height on image
- 12:28, 9 April 2018 diff hist +292 Tube Furnace (Tystar 8300) link to thermal recipes page, minor tweaks otherwsie Tag: Visual edit
- 12:20, 9 April 2018 diff hist 0 m Thermal Processing Recipes →1050°C Dry Oxidation: correction to pressures Tag: Visual edit
- 12:19, 9 April 2018 diff hist -8 m Thermal Processing Recipes →1050°C Wet Oxidation: image adjust Tag: Visual edit
- 12:17, 9 April 2018 diff hist +583 Thermal Processing Recipes →Thermal Oxidation of Silicon: added simulation/data for Wet1050 and Dry1050 Tag: Visual edit: Switched