Vacuum Deposition Recipes

From UCSB Nanofab Wiki
Revision as of 17:16, 5 August 2024 by Noahdutra (talk | contribs) (added Ebeams rankings)
Jump to navigation Jump to search

Process Control Data

See linked page for process control data (calibration data over time, such as dep. rate, refractive index, stress etc.) over time, for a selection of highly used tools/films.

Deposition Tools/Materials Table

The Key/Legend for this table's A...R6 values is at the bottom of the page.

Vacuum Deposition Recipes

E-Beam Evaporation Sputtering Thermal Evaporation Plasma Enhanced Chemical
Vapor Deposition (PECVD)
Atomic Layer Deposition Molecular Vapor Deposition
Material E-Beam 1 (Sharon) E-Beam 2 (Custom) E-Beam 3 (Temescal) E-Beam 4 (CHA) Sputter 3
(AJA ATC 2000-F)
Sputter 4
(AJA ATC 2200-V)
Sputter 5 (AJA ATC 2200-V) Ion Beam
Deposition (Veeco Nexus)
Thermal
Evap 1
Thermal Evap 2 (Solder) PECVD 1
(PlasmaTherm 790)
PECVD 2
(Advanced Vacuum)
Unaxis VLR ICP-PECVD Atomic Layer Deposition (Oxford FlexAL) Molecular Vapor Deposition (Tool)
Ag R2
R2 R2 A A








Al R2
R2 R2 A R1
R1 A A




Al2O3 R2

A R1
R5




R4
AuGe R1
AlN



A A
R1




R4
Au R2
R2 R2 A R1

A A




B














C R3
CeO2
R3












Co R2

R2 R









Cr R1

R2 R


A A




Cu R1


R1 A








Fe R2

R2 R









Ge R2
R2 R2 A A








GeO2 R2
Gd R2

R1










Hf R1


R1











HfO2



A A






R4
In








A




Ir R1

R1










ITO
R3

A A
R1






MgF2 A A
MgO R2
Mo R2


R A








Nb R2



R








Nd



A








Ni R2
R2 R2 R1


A A




NiCr R2 R2
NiFe R1 R2 A
Pd R2
R2 R2



A A




Pt R2
R2 R2 A R1 R1





R4
Ru R2

R2
R






R4
Si
R2

R A
R1


R3

SiN



R1 A
R6

R6 R6 R6

SiN - Low Stress R4 R6 R6
SiO2 R2 R2

R1 A A R6

R6 R6 R6 R4
SiOx R1
SiOxNy






R3

R4



Sn








A




SrF2
R2












Ta R1


R1 A
R1






Ta2O5
R1
R1


R6






Ti R2
R2 R2 R1 R1 R1 R1






TiN




R
R1




R4
TiW R1


A R1








TiO2
R2

A R1
R5




R4
V



A A








W R2


A R1








Zn







A A




ZnO












R3
Zr R2

R2 A A








ZrO2












R4
Material E-Beam 1 (Sharon) E-Beam 2 (Custom) E-Beam 3 (Temescal) E-Beam 4 (CHA) Sputter 3
(ATC 2000-F)
Sputter 4
(ATC 2200-V)
Sputter 5 (ATC 2200-V) Ion Beam
Deposition (Veeco Nexus)
Thermal
Evap 1
Thermal Evap 2 (Solder) PECVD 1
(PlasmaTherm 790)
PECVD 2
(Advanced Vacuum)
Unaxis VLR ICP-PECVD Atomic Layer Deposition (Oxford FlexAl) Molecular Vapor Deposition (Tool)

Process Ranking Table

Processes in the table above are ranked by their "Process Maturity Level" as follows:

Process Level Description of Process Level Ranking
A Process Allowed and materials available but never done
R1 Process has been ran at least once
R2 Process has been ran and/or procedure is documented or/and data available
R3 Process has been ran, procedure is documented, and data is available
R4 Process has a documented procedure with regular (≥4x per year) data or lookahead/in-Situ control available
R5 Process has a documented procedure with regular (≥4x per year) data and lookahead/in-Situ control available
R6 Process has a documented procedure, regular ( ≥4x per year) data, and control charts/limits available