Process Group Internships

From UCSB Nanofab Wiki
Revision as of 18:49, 11 September 2025 by John d (talk | contribs) (links to spc data and tools etc)
Jump to navigation Jump to search

The NanoFab hosts UCSB Undergraduate Interns throughout the school year and summer.

Internship Goals

Our goals are twofold:

  1. Increased Tool Uptime: Acquire Process Control Data so NanoFab staff can proactively identify equipment/process problems, and
  2. Industry-Relevant Experience: Give Interns hands-on industry-relevant experience to minimize the training required at any microelectronics company/research group.


The skills acquired for each goal are as follows:

Industry-relevant Experience

  • Protocols: Interns become comfortable in a busy semiconductor 'fab environment. After 2-3 months of regular usage the interns are fully comfortable with:
    • Cleanroom safety & protocols such as PPE, safe waste disposal etc.
    • Managing their own schedule to accomplish weekly processing tasks.
    • Multi-tasking to run simultaneous processes fast and efficiently.
      • Interns learn new tools only once their current cals have been condensed into a few hours.
    • Communications with
      • lab users (scheduling around other users)
      • equipment engineers (training, handling/reporting tool issues)
      • process supervisors/managers (reviewing process control data, OCAP actions)
  • Equipment: Become comfortable with learning different Operating Procedures of similar tool types
    • Eg. 4 different plasma depositions, 4 different ICP etchers etc.
    • Once an intern has learned 3 different PECVD deposition tools, it is trivial to learn a new PECVD tool even from an unfamiliar manufacturer.
  • MES: Learn to utilize production tracking/communications tools
    • Travelers/Process Followers & associated data directories are created and filled out at run-time for every calibration. (Digital/online via Google Sheets+Drive)
    • Combining Equipment Operating Procedures with Process Travelers instructions at run-time.
    • Data collection with standardized digital filenames & directory structures, available online to all lab users.
    • Click on the date of any SPC data row here to see a Traveler & Data folder filled out by interns (or here is one example).
      • Every Calibration process has the same format: see other intern-run processes here: Process Control Data
  • SPC: Perform metrology, process control, create SPC charts
    • Data from the Travelers are entered into online spreadsheets, which calculate SPC charts
    • Some interns create/modify SPC charts when needed for newly developed Cals.
    • See the intern-generated SPC data here: Process Control Data
  • OCAP/Repair: Work with tool engineers to identify & diagnose equipment problems.
    • If Process Engineers identify an Out-of-Control process, Interns are involved in the communications & testing of tool repairs.

Process Control for Increased Uptime

  • Interns run process-control on the lab's most critical/high-usage tools.
  • Calibration processes are identical each time (unlike lab user's processes), allowing apples-to-apples comparisons.
  • Regular meetings with Process Engineers allow us to proactively identify equipment/process issues, failing tool components, and schedule repairs/remedies sooner than if detected by a lab user.
  • Lab users are notified of process anomalies & repair plans, reducing bad outcomes for lab users.
  • "Contamination" checks via On-Demand process-checks
    • Determine whether a new process affects other processes on the same tool, by running pre/post Cal Etches.
    • On ICP Etchers, enables data-driven equipment sharing between processes.
    • Enables lab-users to quickly determine whether problems lie with the Equipment/"contamination", another user's process or their own Process.

Job Description: 2 phases

Internships are generally run in 2 phases, with each phase being approx. 1 Quarter (3 months) long.

Phase 1: Deposition Cals (1st Quarter)

  • Interns run 4 different deposition tools weekly, in the following order:
  • Every film undergoes the following metrology:
  • Follow Process Protocols:
    • Follow and Record Data onto Travelers for every Cal run, save metro data into publicly-accessible folders.
    • Update all SPC data tables and charts accurately, report any "out of control" process issues.
  • By the end of 1st Quarter, Interns are running 9-12 thin-film cals every 2 weeks.

Phase 2: EtchCals and LithoCals (2nd Quarter)

  • Interns run 4 different ICP Etchers weekly:
  • Metrology on each EtchCal:
    • SEM of manually Cleaved Cross-section
    • Cleaving samples for cross-sectional SEM.
    • Profilometry & Etch-Rate Calculation
    • Etch Selectivity Calculation via pre/post hardmask removal profilometry
  • Interns run weekly ASML DUV Stepper lithography: photoresist coating, exposure and develop.
    • Critical particulate-sensitive process, cal shows any particles present
      • Intern's techniques are remedied if particles are detected.
  • Metro on each LithoCal:
    • SEM for Critical Dimension measurement; multiple locations on wafer.
    • Identification of "hotspot" particulate contamination on wafer/tool.
  • Follow Process Protocols:
    • Follow and Record Data onto Travelers for every Cal run, save metro data into publicly-accessible folders.
    • Update all SPC data tables and charts accurately, report any "out of control" process issues.
  • By the end of 2nd Quarter, Interns are running LithoCals and ~2 EtchCals weekly, with multiple SEM sessions. They are proficient at SEM by the end of the 2nd quarter.