Search results
Jump to navigation
Jump to search
- .../index.php?title=Tool_List#Thermal_Processing See the full list of Thermal Processing tools here.]2 KB (211 words) - 09:41, 24 August 2022
- |type = Thermal Processing2 KB (229 words) - 10:53, 20 September 2023
- ...brication tools and equipment, such as vacuum deposition, etchers, thermal processing etc. ...The Process Group helps to ensure that equipment is providing the expected processing capabilities.5 KB (664 words) - 09:42, 11 March 2024
- |type = Thermal Processing2 KB (268 words) - 14:50, 30 October 2023
- ...ely 10 um, allowing for measurement of thin films at various points in the processing.2 KB (274 words) - 07:30, 13 May 2022
- ...eeexplore.ieee.org/abstract/document/546406/ Etch rates for Micromachining Processing (IEEE Jnl. MEMS, 1996)] - includes tables of etch rates of numerous metals ...re.ieee.org/xpls/abs_all.jsp?arnumber=546406 Etch rates for micromachining processing]10 KB (1,405 words) - 10:34, 1 April 2024
- |type = Wet Processing2 KB (340 words) - 14:41, 8 November 2022
- ...t and versatile FIB patterning for simplified, flexible, 3D, and automated processing2 KB (285 words) - 09:56, 15 March 2021
- ...r]], or a custom graphite fixture in conjunction with any one of [[Thermal Processing|numerous ovens]], such as the N2-purged [[Tube Furnace Wafer Bonding (Therm [[Category:Processing]]5 KB (713 words) - 16:24, 30 January 2024
- ...he was a Senior Engineer working on optical packaging, III/V semiconductor processing, and facility design and construction. The primary goal at the Goleta Ciena2 KB (333 words) - 08:29, 7 August 2020
- ...wafer surface before HMDS application. This is very important for wet-etch processing through small, high aspect ratio photoresist holes or lines.2 KB (347 words) - 13:06, 11 November 2022
- ...system is load-locked and can accommodate sample temperatures up to 550°C. Processing temperature windows are defined for each material based on growth limitatio3 KB (377 words) - 14:56, 8 March 2023
- *Clean excess wax off your wafer using the [[Wet Benches#Automated Wet-processing Spinners .28POLOS.29|POLOS Spinners]], and an Acetone squirt bottle, follow3 KB (531 words) - 10:52, 26 April 2023
- ...enclosed emergency showers is located in bay 5 across from the HF/TMAH wet processing bench. If using the emergency shower at the end of the bay, water will spi ...storage area (except HF) is the acid cabinet located next to the acid wet processing benches in bay 5. HF acid is stored in the HF cabinet34 KB (5,514 words) - 11:07, 3 August 2018
- [[Category:Processing]]14 KB (1,875 words) - 15:31, 7 February 2024
- [[Category:Processing]]24 KB (3,097 words) - 15:44, 7 July 2022
- *Glassware for chemical processing (developer/water/solvent/acid/base). Pyrex required for heating. Watch glas ==Processing/Fabrication Questions==25 KB (4,202 words) - 20:37, 13 May 2024
- ...phy_Recipes#Photolithography_Recipes Photolith. Recipes Page] for detailed processing info (bakes/spins/exposure does etc.). Basic photoresists include:6 KB (893 words) - 17:44, 12 February 2024
- ...px|After clicking HELP button on an error window "Fatal error during batch processing", showing the error chain. This shows that the system was unable to pick up8 KB (1,341 words) - 10:36, 15 September 2023
- ...ul for general observations, measurements, inspections after etching/other processing steps, distinguishing residues vs. delamination, to name a few.11 KB (1,710 words) - 12:41, 16 October 2023