Help
Uploads by Ningcao
Jump to navigation
Jump to search
This special page shows all uploaded files.
File list
Items per page:
20
50
100
250
500
Username:
Include old versions of files
Show file list
First page
Previous page
Next page
Last page
Date
Name
Thumbnail
Size
Description
Versions
21:39, 11 September 2013
01-ICP-PECVD-a-Si-Deposition Recipe-250C.pdf
(
file
)
495 KB
1
23:03, 11 September 2013
03-Amorphous-Si-PECVD-2.pdf
(
file
)
248 KB
1
23:08, 11 September 2013
02-ICP-PECVD-a-Si Film-90C.pdf
(
file
)
131 KB
1
16:07, 17 September 2013
05-SiO2 Nano-structure Etch.pdf
(
file
)
937 KB
1
18:36, 17 September 2013
06-XeF2-etch-recipe.pdf
(
file
)
312 KB
1
22:42, 18 September 2013
07-GaN Etch-Panasonic-ICP-1.pdf
(
file
)
1.43 MB
1
22:40, 19 September 2013
08-Plasma Etching of GaN-RIE5.pdf
(
file
)
706 KB
1
21:13, 24 September 2013
09-Plasma Etching of GaN-UnaxisPM1.pdf
(
file
)
500 KB
1
16:59, 25 September 2013
10-Si Etch using DRIE (single-step).pdf
(
file
)
843 KB
1
18:16, 27 September 2013
11-CZT etching-1.pdf
(
file
)
110 KB
1
17:58, 2 October 2013
12-Plasma Etching of AlGaAs-Panasonic ICP-1-Etcher.pdf
(
file
)
870 KB
1
18:26, 2 October 2013
13-GaAs-AlGaAs Etching-RIE-5.pdf
(
file
)
599 KB
1
20:41, 2 October 2013
15-GaAs etch-Unaxis ICP etcher.pdf
(
file
)
765 KB
1
20:47, 2 October 2013
14-AlAs-GR-cal etch-Unaxis ICP etcher.pdf
(
file
)
671 KB
1
23:11, 2 October 2013
16-GaAs etch-ICP-2.pdf
(
file
)
229 KB
1
15:19, 3 October 2013
17-InP&InGaAs etch-Cl2H2Ar-Unaxis-VLR.pdf
(
file
)
1,009 KB
1
17:40, 3 October 2013
18-InP-based etching-Cl2N2Ar.pdf
(
file
)
985 KB
1
16:02, 7 October 2013
19-AlN-Sputtering-Film-Sputter-2.pdf
(
file
)
157 KB
1
16:19, 7 October 2013
20-Al-Sputtering-Film-Sputter-2.pdf
(
file
)
599 KB
1
17:37, 10 October 2013
21-Au-Sputter-film-recipes-Sputter-2.pdf
(
file
)
240 KB
1
17:22, 28 October 2013
22-TiO2-Film-Sputter-2.pdf
(
file
)
172 KB
1
19:23, 5 November 2013
24-Ni and Ta Films using Sputter-3.pdf
(
file
)
165 KB
1
19:39, 30 January 2014
IMG 2416 1.jpg
(
file
)
93 KB
1
23:41, 30 January 2014
SPTS-Primaxx uEtch Presentation-a.pdf
(
file
)
1.89 MB
1
23:44, 30 January 2014
SPTS-Primaxx uEtch Presentation-b.pdf
(
file
)
1.78 MB
1
23:57, 30 January 2014
25-Dry Etch of Unaxis ICP-grown SiO2 using Vapor HF tool-a.pdf
(
file
)
1.74 MB
1
23:59, 30 January 2014
26-Dry Etch of Unaxis ICP-grown SiO2 using Vapor HF tool-b.pdf
(
file
)
1.07 MB
1
21:03, 18 March 2014
23-Tungsten Sputtering Film-Sputter-4-Ar.pdf
(
file
)
310 KB
1
22:09, 18 March 2014
27-SiNx Film (Bias=50W) Sidewall Coverage.pdf
(
file
)
150 KB
1
22:28, 18 March 2014
28-Very-low-pin-hole-density SiNx film at 300 C.pdf
(
file
)
410 KB
1
23:10, 17 April 2014
29-UnaxisPM3-SiO2-SiH4-O2-He.pdf
(
file
)
88 KB
1
21:11, 18 April 2014
30-Redicing Nanowire Diameter by Thermal Oxidation and Vapored HF Etch.pdf
(
file
)
1.31 MB
1
21:22, 18 April 2014
31-Holography Process for 1D-lines and 2D-dots-rev-3-13-2014.pdf
(
file
)
624 KB
1
16:22, 21 January 2015
32-Reducing AlCl3 Corrosion with CHF3 plasma.pdf
(
file
)
636 KB
1
17:21, 27 January 2015
33-Etching SiO2 with Vertical Side-wall.pdf
(
file
)
924 KB
1
22:06, 22 June 2015
THMR-iP3600 HP D 20140801 (B) GHS US.pdf
(
file
)
292 KB
1
22:10, 22 June 2015
THMR iP 3500 iP3600.pdf
(
file
)
1.4 MB
1
22:12, 22 June 2015
3600 D, D2v Spin Speed Curve.pdf
(
file
)
52 KB
1
22:27, 29 June 2015
35-Low-stress SiNx at 250 C using Unaxis ICP deposition tool.pdf
(
file
)
118 KB
1
22:59, 29 June 2015
34-High-stress SiNx at 250 C using Unaxis ICP deposition tool.pdf
(
file
)
10 KB
1
23:15, 29 June 2015
36-Medium-stress SiNx using Unaxis ICP deposition tool.pdf
(
file
)
16 KB
1
18:39, 30 June 2015
37-Low-stress SiNx at 100 C using Unaxis ICP deposition tool.pdf
(
file
)
169 KB
1
18:55, 30 June 2015
38-High-stress SiNx at 100 C using Unaxis ICP deposition tool.pdf
(
file
)
43 KB
1
19:07, 30 June 2015
39-Medium-stress SiNx at 100C using Unaxis ICP deposition tool.pdf
(
file
)
48 KB
1
20:58, 22 July 2015
42-Etching Platinum using Oxford Ion Mill Tool.pdf
(
file
)
1.62 MB
1
21:08, 22 July 2015
42-Etching Platinum using Oxford Ion Mill Tool-a.pdf
(
file
)
1.62 MB
1
21:36, 2 September 2015
43-Issue with the etch of InP-InGaAs-and- InAlAs-b.pdf
(
file
)
838 KB
1
22:49, 9 October 2015
44-Etching Gold with Al2O3 Mask using Oxford Ion Mill Tool.pdf
(
file
)
2.28 MB
1
23:23, 1 December 2015
45-Etching Nickel with Al2O3 Mask using Oxford Ion Mill Tool.pdf
(
file
)
1.87 MB
1
23:42, 16 December 2015
46-Mo Film using Sputter3.pdf
(
file
)
143 KB
1
First page
Previous page
Next page
Last page
Navigation menu
Personal tools
Create account
Log in
Namespaces
Special page
English
Views
More
Search
InvisibleMenu
QuickLinks
Lab Rules
Common Questions/FAQ
Staff List
Equipment Signup
Chemicals + MSDS
Protofab
Equipment
Full Tool List
Lithography
Vacuum Deposition
Dry Etch
Wet Processing
Thermal Processing
Packaging
Metrology & Test
Recipes and Data
Lithography
Vacuum Deposition
Dry Etching
Wet Etching
Thermal Processing
Packaging Tools
Data + Info
Process Control Data
Tutorials
Calculators/Utilities
NanoFab Info
Research + Pubs
Tech Talks
Tools
User contributions
Logs
View user groups
Special pages
Printable version