Process Group Internships: Difference between revisions

From UCSB Nanofab Wiki
Jump to navigation Jump to search
Content deleted Content added
mNo edit summary
mNo edit summary
 
(5 intermediate revisions by the same user not shown)
Line 1: Line 1:
The NanoFab hosts UCSB Undergraduate Interns throughout the school year and summer.
The NanoFab hosts UCSB Undergraduate Interns throughout the school year and summer.

No prerequisites/prior knowledge needed; for anyone 16 years old and up; Minimum 6 months commitment (break during summer is acceptable).

* [[Nanofab Job Postings|Upcoming Internship Openings]]
* [[Process Group Interns|Current Interns]]

<br>

__TOC__


=== Internship Goals ===
=== Internship Goals ===
Line 10: Line 19:
The skills acquired for each goal are as follows:
The skills acquired for each goal are as follows:


=== Industry-relevant Experience ===
==== Industry-relevant Experience ====

* '''Protocols''': Interns become comfortable in a busy semiconductor 'fab environment. After 2-3 months of regular usage the interns are fully comfortable with:
* '''Protocols''': Interns become comfortable in a busy semiconductor 'fab environment. After 2-3 months of regular usage the interns are fully comfortable with:
** Cleanroom safety & protocols such as PPE, safe waste disposal etc.
** Cleanroom safety & protocols such as PPE, safe waste disposal etc.
Line 19: Line 27:
** Communications with
** Communications with
*** lab users (scheduling around other users)
*** lab users (scheduling around other users)
*** equipment staff (reporting tool issues)
*** equipment engineers (training, handling/reporting tool issues)
*** process supervisors/managers (reviewing process control data)
*** process supervisors/managers (reviewing process control data, OCAP actions)
* '''Equipment''': Become comfortable with learning different SOP's of similar tool types
* '''Equipment''': Become comfortable with learning different Operating Procedures of similar tool types
** Eg. 4 different plasma depositions, 4 different ICP etchers etc.
** Eg. 4 different plasma depositions, 4 different ICP etchers etc.
** Once an intern has learned 3 different PECVD deposition tools, it is trivial to learn a new PECVD tool even from an unfamiliar manufacturer.
** Once an intern has learned 3 different PECVD deposition tools, it is trivial to learn a new PECVD tool even from an unfamiliar manufacturer.
Line 28: Line 36:
** Combining ''Equipment Operating Procedures'' with ''Process Travelers'' instructions at run-time.
** Combining ''Equipment Operating Procedures'' with ''Process Travelers'' instructions at run-time.
** Data collection with standardized digital filenames & directory structures, available online to all lab users.
** Data collection with standardized digital filenames & directory structures, available online to all lab users.
** [https://docs.google.com/spreadsheets/d/1fTDNXxpf4tgNYLIEs_jvehG1KvtXqqTRDBI7sHNAVvo/edit?gid=0#gid=0 Click on the '''date''' of any SPC data row here to see a Traveler & Data folder] filled out by interns (or here is [https://drive.google.com/drive/folders/10v4pElyxNBTe4kJw8fMtuBtj54M5vkPx one example]).
*** Every Calibration process has the same format: see other intern-run processes here: [[Process Group - Process Control Data|Process Control Data]]
* '''[https://en.wikipedia.org/wiki/Statistical_process_control SPC]''': Perform metrology, process control, create SPC charts
* '''[https://en.wikipedia.org/wiki/Statistical_process_control SPC]''': Perform metrology, process control, create SPC charts
** Data from the Travelers are entered into online spreadsheets, which calculate SPC charts
** Data from the Travelers are entered into online spreadsheets, which calculate SPC charts
** Some interns create/modify SPC charts when needed for newly developed Cals.
** Some interns create/modify SPC charts when needed for newly developed Cals.
** See the intern-generated SPC data here: [[Process Group - Process Control Data|Process Control Data]]
* '''OCAP/Repair''': Work with tool engineers to identify & diagnose equipment problems.
* '''OCAP/Repair''': Work with tool engineers to identify & diagnose equipment problems.
** If Process Engineers identify an Out-of-Control process, Interns are involved in the communications & testing of tool repairs.
** If Process Engineers identify an Out-of-Control process, Interns are involved in the communications & testing of tool repairs, until process is back "in control".


=== Process Control for Increased Uptime ===
==== Process Control (SPC) for Increased Uptime ====
⚫
* Interns run process-control on the lab's most critical/high-usage tools & update [[Process Group - Process Control Data|SPC charts]].

⚫
* Interns run process-control on the lab's most critical/high-usage tools.
* Calibration processes are identical each time (unlike lab user's processes), allowing apples-to-apples comparisons.
* Calibration processes are identical each time (unlike lab user's processes), allowing apples-to-apples comparisons.
* Regular meetings with Process Engineers allow us to proactively identify equipment/process issues, failing tool components, and schedule repairs/remedies sooner than if detected by a lab user.
* Regular meetings with Process Engineers allow us to proactively identify equipment/process issues, failing tool components, and schedule repairs/remedies sooner than if detected by a lab user.
Line 50: Line 60:
=== Phase 1: Deposition Cals (1st Quarter) ===
=== Phase 1: Deposition Cals (1st Quarter) ===


* Interns learn 4 different deposition tools, in the following order:
* Interns run 4 different deposition tools weekly, in the following order:
** Plasmatherm PECVD 1
** [[PECVD 1 (PlasmaTherm 790)|Plasmatherm PECVD 1]]
** Advanced Vacuum PECVD 2,
** [[PECVD 2 (Advanced Vacuum)|Advanced Vacuum PECVD 2]],
** Unaxis ICP-PECVD,
** [[ICP-PECVD (Unaxis VLR)|Unaxis ICP-PECVD]],
** Veeco Ion Beam Deposition
** [[Ion Beam Deposition (Veeco NEXUS)|Veeco Ion Beam Sputter Deposition]]
** 3-4 different films (SiO<sub>2</sub>, Si<sub>3</sub>N<sub>4</sub>, Low-stress-Si<sub>3</sub>N<sub>4</sub>) are run on <u>each tool</u>.
** 3-4 different films (SiO<sub>2</sub>, Si<sub>3</sub>N<sub>4</sub>, Low-stress-Si<sub>3</sub>N<sub>4</sub>) are run on <u>each tool</u>.
* Every film undergoes the following metrology:
* Every film undergoes the following metrology:
** Ellipsometry: Thin-film thickness and refractive index at 2 different wavelengths.
** [[Ellipsometer (Woollam)|Ellipsometry]]: Thin-film thickness and refractive index at 2 different wavelengths.
** Reflectometry Wafer Mapping: Thin-film Uniformity across the wafer.
** [[Optical Film Thickness & Wafer-Mapping (Filmetrics F50)|Reflectometry Wafer Mapping]]: Thin-film Uniformity across the wafer.
** Particle Count: laser-scanning via Surfscan, at two different particle-size/range settings
** [[Surface Analysis (KLA/Tencor Surfscan)|Particle Count]]: laser-scanning via Surfscan, at two different particle-size/range settings
** Thin-Film Stress: requires before & after wafer bow measurements via laser scanning
** [[Film Stress (Tencor Flexus)|Thin-Film Stress]]: requires before & after wafer bow measurements via laser scanning
* Follow Process Protocols:
** Follow and Record Data onto Travelers for every Cal run, save metro data into publicly-accessible folders.
** Update all [[Process Group - Process Control Data|SPC data tables]] and charts accurately, report any "out of control" process issues.
* By the end of 1st Quarter, Interns are running 9-12 thin-film cals every 2 weeks.
* By the end of 1st Quarter, Interns are running 9-12 thin-film cals every 2 weeks.


=== Phase 2: EtchCals and LithoCals (2nd Quarter) ===
=== Phase 2: EtchCals and LithoCals (2nd Quarter) ===


* Interns learn 4 different ICP Etchers:
* Interns run 4 different ICP Etchers weekly:
** Plasmatherm SLR Fluorine Etcher
** [[Fluorine ICP Etcher (PlasmaTherm/SLR Fluorine ICP)|Plasmatherm SLR Fluorine ICP Etcher]] - SiO2 and Si etching
** Oxford Cobra III-V Etcher
** [[Oxford ICP Etcher (PlasmaPro 100 Cobra)|Oxford Cobra III-V ICP Etcher]] - InP etching
** Plasmatherm DSEiii
** [[DSEIII (PlasmaTherm/Deep Silicon Etcher)|Plasmatherm DSEiii]] - Bosch etching of Silicon
** Panasonic ICP #2
** [[ICP Etch 2 (Panasonic E626I)|Panasonic ICP #2]] - SiO2 and GaAs etching
** 1-2 different Etches per tool; one "insensitive" to chamber condition, one "sensitive" to chamber condition.
** 1-2 different Etches per tool; one "insensitive" to chamber condition, one "sensitive" to chamber condition.
⚫
* Interns learn ASML DUV Stepper lithography: photoresist coating, exposure and develop.
⚫
** Critical particulate-sensitive process, cal shows any particles present
⚫
*** Intern's techniques are remedied if particles are detected.
* Metrology on each EtchCal:
* Metrology on each EtchCal:
** SEM of manually Cleaved Cross-section
** [[SEM 1 (JEOL IT800SHL)|SEM]] of manually Cleaved Cross-section
** Cleaving samples for cross-sectional SEM.
** Profilometry & Etch-Rate Calculation
** [[Step Profilometer (DektakXT)|Profilometry]] & Etch-Rate Calculation
** Etch Selectivity Calculation via pre/post hardmask removal profilometry
** Etch Selectivity Calculation via pre/post hardmask removal profilometry
⚫
* Interns run weekly [[Stepper 3 (ASML DUV)|ASML DUV Stepper lithography]]: photoresist coating, exposure and develop.
⚫
** Critical particulate-sensitive process, cal shows any particles present
⚫
*** Intern's techniques are remedied if particles are detected.
* Metro on each LithoCal:
* Metro on each LithoCal:
** SEM for Critical Dimension measurement; multiple locations on wafer.
** [[SEM 1 (JEOL IT800SHL)|SEM]] for Critical Dimension measurement; multiple locations on wafer.
** Identification of "hotspot" particulate contamination on wafer/tool.
** Identification of "hotspot" particulate contamination on wafer/tool.
* Follow Process Protocols:
⚫
* By the end of 2nd Quarter, Interns are running LithoCals and ~2 Etchcals weekly, with multiple SEM sessions. They are proficient at SEM by the end of the 2nd quarter.
** Follow and Record Data onto Travelers for every Cal run, save metro data into publicly-accessible folders.
** Update all [[Process Group - Process Control Data|SPC data tables]] and charts accurately, report any "out of control" process issues.
⚫
* By the end of 2nd Quarter, Interns are running LithoCals and ~2 EtchCals weekly, with multiple SEM sessions. They are proficient at SEM by the end of the 2nd quarter.

Latest revision as of 00:33, 11 January 2026

The NanoFab hosts UCSB Undergraduate Interns throughout the school year and summer.

No prerequisites/prior knowledge needed; for anyone 16 years old and up; Minimum 6 months commitment (break during summer is acceptable).


Internship Goals

Our goals are twofold:

  1. Increased Tool Uptime: Acquire Process Control Data so NanoFab staff can proactively identify equipment/process problems, and
  2. Industry-Relevant Experience: Give Interns hands-on industry-relevant experience to minimize the training required at any microelectronics company/research group.


The skills acquired for each goal are as follows:

Industry-relevant Experience

  • Protocols: Interns become comfortable in a busy semiconductor 'fab environment. After 2-3 months of regular usage the interns are fully comfortable with:
    • Cleanroom safety & protocols such as PPE, safe waste disposal etc.
    • Managing their own schedule to accomplish weekly processing tasks.
    • Multi-tasking to run simultaneous processes fast and efficiently.
      • Interns learn new tools only once their current cals have been condensed into a few hours.
    • Communications with
      • lab users (scheduling around other users)
      • equipment engineers (training, handling/reporting tool issues)
      • process supervisors/managers (reviewing process control data, OCAP actions)
  • Equipment: Become comfortable with learning different Operating Procedures of similar tool types
    • Eg. 4 different plasma depositions, 4 different ICP etchers etc.
    • Once an intern has learned 3 different PECVD deposition tools, it is trivial to learn a new PECVD tool even from an unfamiliar manufacturer.
  • MES: Learn to utilize production tracking/communications tools
    • Travelers/Process Followers & associated data directories are created and filled out at run-time for every calibration. (Digital/online via Google Sheets+Drive)
    • Combining Equipment Operating Procedures with Process Travelers instructions at run-time.
    • Data collection with standardized digital filenames & directory structures, available online to all lab users.
    • Click on the date of any SPC data row here to see a Traveler & Data folder filled out by interns (or here is one example).
      • Every Calibration process has the same format: see other intern-run processes here: Process Control Data
  • SPC: Perform metrology, process control, create SPC charts
    • Data from the Travelers are entered into online spreadsheets, which calculate SPC charts
    • Some interns create/modify SPC charts when needed for newly developed Cals.
    • See the intern-generated SPC data here: Process Control Data
  • OCAP/Repair: Work with tool engineers to identify & diagnose equipment problems.
    • If Process Engineers identify an Out-of-Control process, Interns are involved in the communications & testing of tool repairs, until process is back "in control".

Process Control (SPC) for Increased Uptime

  • Interns run process-control on the lab's most critical/high-usage tools & update SPC charts.
  • Calibration processes are identical each time (unlike lab user's processes), allowing apples-to-apples comparisons.
  • Regular meetings with Process Engineers allow us to proactively identify equipment/process issues, failing tool components, and schedule repairs/remedies sooner than if detected by a lab user.
  • Lab users are notified of process anomalies & repair plans, reducing bad outcomes for lab users.
  • "Contamination" checks via On-Demand process-checks
    • Determine whether a new process affects other processes on the same tool, by running pre/post Cal Etches.
    • On ICP Etchers, enables data-driven equipment sharing between processes.
    • Enables lab-users to quickly determine whether problems lie with the Equipment/"contamination", another user's process or their own Process.

Job Description: 2 phases

Internships are generally run in 2 phases, with each phase being approx. 1 Quarter (3 months) long.

Phase 1: Deposition Cals (1st Quarter)

  • Interns run 4 different deposition tools weekly, in the following order:
  • Every film undergoes the following metrology:
  • Follow Process Protocols:
    • Follow and Record Data onto Travelers for every Cal run, save metro data into publicly-accessible folders.
    • Update all SPC data tables and charts accurately, report any "out of control" process issues.
  • By the end of 1st Quarter, Interns are running 9-12 thin-film cals every 2 weeks.

Phase 2: EtchCals and LithoCals (2nd Quarter)

  • Interns run 4 different ICP Etchers weekly:
  • Metrology on each EtchCal:
    • SEM of manually Cleaved Cross-section
    • Cleaving samples for cross-sectional SEM.
    • Profilometry & Etch-Rate Calculation
    • Etch Selectivity Calculation via pre/post hardmask removal profilometry
  • Interns run weekly ASML DUV Stepper lithography: photoresist coating, exposure and develop.
    • Critical particulate-sensitive process, cal shows any particles present
      • Intern's techniques are remedied if particles are detected.
  • Metro on each LithoCal:
    • SEM for Critical Dimension measurement; multiple locations on wafer.
    • Identification of "hotspot" particulate contamination on wafer/tool.
  • Follow Process Protocols:
    • Follow and Record Data onto Travelers for every Cal run, save metro data into publicly-accessible folders.
    • Update all SPC data tables and charts accurately, report any "out of control" process issues.
  • By the end of 2nd Quarter, Interns are running LithoCals and ~2 EtchCals weekly, with multiple SEM sessions. They are proficient at SEM by the end of the 2nd quarter.