Processing - How Do I…?: Difference between revisions
(initial holders) |
(→Design of Experiments: DOE exmaple, added Trello and gDrive examples and llinks etc.) |
||
(One intermediate revision by the same user not shown) | |||
Line 2: | Line 2: | ||
== Lithography == |
== Lithography == |
||
placeholder |
|||
=== Mask Plates - How do I order a mask plate? === |
|||
* [[Mask Making Guidelines for Contact Aligners|How to order a contact mask plate]] |
|||
* [[Autostep 200 Mask Making Guidance|How to order a mask plate for the GCA Steppers]] |
|||
* [[Stepper 3 (ASML DUV)#Mask Design and CAD files|How to order an ASML mask plate]] |
|||
=== Calibration - How do I determine the correct exposure Dose/Focus? === |
|||
On tools that have motorized autofocus (steppers & direct-write litho tools), you often need to analyze both the Focus Offset & Exposure Dose simultaneously. (Remember that "Focus Offset" is an offset from the autofocus' "zero" position of the wafer surface.) These tools will have a function for shooting a "Focus Exposure Matrix/Array", or "FEM/FEA", which exposes a grid with Dose varying in one direction, and Focus varying in another - the following explains how to find the [https://en.wikipedia.org/wiki/Process_window Process Window] from your FEM: |
|||
* [[Lithography Calibration - Analyzing a Focus-Exposure Matrix]] |
|||
== Deposition == |
== Deposition == |
||
Line 32: | Line 42: | ||
== Experiment Setup == |
== Experiment Setup == |
||
=== Design of Experiments === |
=== Design of Experiments (DOE) === |
||
[https://en.wikipedia.org/wiki/Design_of_experiments Design of Experiments] is essentially a way to apply the Scientific Method (''hypothesis → variables → measurements → conclusions'') to determining a physical manufacturing process, by varying process parameters and measuring outcomes in a controlled manner, allowing you to figure out |
|||
placeholder |
|||
(a) how each parameter affects the process, |
|||
(b) identify a process good enough for your needs, |
|||
(c) what the [https://en.wikipedia.org/wiki/Process_window process window] is for this process (ie. if parameters fluctuate randomly, will your process still work). |
|||
One way to organize your experiments and measurements is with a spreadsheet; here is an example Spreadsheet and associated SEM's for developing a dry etch: |
|||
[https://drive.google.com/open?id=19OCiG93M5KppQ1ckX0mIba1ckhRLdMqY&usp=drive_fs 2023-09 InP Vertical Etch DOE] |
|||
=== Travelers (aka. RunCards, Process Followers, Work Instructions) === |
|||
Travelers are a critical way to |
|||
(a) plan out your fabrication before you start, |
|||
(b) record what actually happened during a fabrication run, and |
|||
(c) allow you to copy and modify existing/previous processes (avoiding redeveloping steps). |
|||
In the [https://drive.google.com/drive/folders/19OEkrt4vjdw41Ys_5a3VAOyj7NIRNb1o?usp=sharing example traveler linked here], the critical columns are |
|||
# The steps to be performed |
|||
# The details of the step (eg. "why" you are doing the step) |
|||
# The Wafer tracking columns on the right where you record |
|||
## The initials and date to indicate the step was completed, and/or |
|||
## Notes on what you changed/didn't work etc. |
|||
[https://docs.google.com/spreadsheets/d/19fr-HveCyWTcF-TdIgYJKx5eND1_HWIs/edit?gid=1764420288#gid=1764420288 '''Example Traveller 2018 (DJ Dual-gate)'''] |
|||
[https://drive.google.com/drive/folders/19OEkrt4vjdw41Ys_5a3VAOyj7NIRNb1o?usp=sharing '''Example Job Folder (for all processing documents)'''] |
|||
=== Tracking your processes === |
=== Tracking your processes === |
||
We have recently set up an example of how the UCSB NanoFab organizes our own fabrication jobs: |
|||
placeholder |
|||
<br /> |
|||
I have an [https://trello.com/invite/b/Oxs8nMlt/ATTIcb107c9120edae48f4ba24b401e083339096A145/example-jobs-board example Trello task tracking board], and corresponding [https://drive.google.com/drive/folders/19N4LyL9eba5DHeaWObbQFAlkFSTQSBA8?usp=sharing Google Drive folder here], showing how we organize our 'fab jobs over the years. We use Shared Drives extensively at the NanoFab, one for each "group" (Equipment/Facilities/Fabrication groups). |
|||
Augmenting human communication and memory, using |
|||
* Trello for job tracking and weekly passdown |
|||
* Google Drive (linked in Trello) for data retention. |
|||
The gDrive folder also contains example Travelers/RunCards/Process Followers and DOE's etc., which I highly recommend writing before you start 'fab or experiments. |
|||
{| class="wikitable" |
|||
|+Examples of Trello + Google Drive for tracking fabrication jobs |
|||
|[[File:Trello - Example Job Cards.png|alt=Trello - Example Job Cards screenshot|none|thumb|367x367px|Tracking to-do and completed tasks.]][[File:Google Drive - Example Job Folder.png|alt=Google Drive - Example Job Folder screenshot|none|thumb|327x327px|Example Job Folder on Google Drive with in-process traveler, microscope/SEM images, testing results etc.]] |
|||
|[[File:Trello - example job card.png|alt=Trello - example job card screenshot|none|thumb|504x504px|Example job card for a fabrication run.]] |
|||
|} |
|||
''Written by [[Demis D. John]], 2024-10-22'' |
Latest revision as of 05:28, 23 October 2024
Below are answers to common processing questions in the NanoFab.
Lithography
Mask Plates - How do I order a mask plate?
- How to order a contact mask plate
- How to order a mask plate for the GCA Steppers
- How to order an ASML mask plate
Calibration - How do I determine the correct exposure Dose/Focus?
On tools that have motorized autofocus (steppers & direct-write litho tools), you often need to analyze both the Focus Offset & Exposure Dose simultaneously. (Remember that "Focus Offset" is an offset from the autofocus' "zero" position of the wafer surface.) These tools will have a function for shooting a "Focus Exposure Matrix/Array", or "FEM/FEA", which exposes a grid with Dose varying in one direction, and Focus varying in another - the following explains how to find the Process Window from your FEM:
Deposition
Metal Deposition
placeholder
Dielectric/Insulator Deposition
placeholder
Etching
Dry (plasma) Etching
placeholder
Wet (chemical) Etching
placeholder
Materials
Material "Quality"
placeholder
Alloying metals
placeholder
Impurities
Experiment Setup
Design of Experiments (DOE)
Design of Experiments is essentially a way to apply the Scientific Method (hypothesis → variables → measurements → conclusions) to determining a physical manufacturing process, by varying process parameters and measuring outcomes in a controlled manner, allowing you to figure out
(a) how each parameter affects the process,
(b) identify a process good enough for your needs,
(c) what the process window is for this process (ie. if parameters fluctuate randomly, will your process still work).
One way to organize your experiments and measurements is with a spreadsheet; here is an example Spreadsheet and associated SEM's for developing a dry etch:
Travelers (aka. RunCards, Process Followers, Work Instructions)
Travelers are a critical way to
(a) plan out your fabrication before you start,
(b) record what actually happened during a fabrication run, and
(c) allow you to copy and modify existing/previous processes (avoiding redeveloping steps).
In the example traveler linked here, the critical columns are
- The steps to be performed
- The details of the step (eg. "why" you are doing the step)
- The Wafer tracking columns on the right where you record
- The initials and date to indicate the step was completed, and/or
- Notes on what you changed/didn't work etc.
Example Traveller 2018 (DJ Dual-gate)
Example Job Folder (for all processing documents)
Tracking your processes
We have recently set up an example of how the UCSB NanoFab organizes our own fabrication jobs:
I have an example Trello task tracking board, and corresponding Google Drive folder here, showing how we organize our 'fab jobs over the years. We use Shared Drives extensively at the NanoFab, one for each "group" (Equipment/Facilities/Fabrication groups).
Augmenting human communication and memory, using
- Trello for job tracking and weekly passdown
- Google Drive (linked in Trello) for data retention.
The gDrive folder also contains example Travelers/RunCards/Process Followers and DOE's etc., which I highly recommend writing before you start 'fab or experiments.
Written by Demis D. John, 2024-10-22