Recent changes

Jump to navigation Jump to search

Track the most recent changes to the wiki on this page.

Recent changes options Show last 50 | 100 | 250 | 500 changes in last 1 | 3 | 7 | 14 | 30 days
Hide registered users | Hide anonymous users | Show my edits | Show bots | Hide minor edits
Show new changes starting from 16:05, 21 August 2024
   
List of abbreviations:
N
This edit created a new page (also see list of new pages)
m
This is a minor edit
b
This edit was performed by a bot
(±123)
The page size changed by this number of bytes

21 August 2024

     12:46  Frequently Asked Questions‎‎ 2 changes history +180 [John d‎ (2×)]
 m   
12:46 (cur | prev) +211 John d talk contribs →‎What Supplies do I need to bring to the lab?: added metal sources Tag: Visual edit
     
12:43 (cur | prev) -31 John d talk contribs reordered Tag: Visual edit
     12:27  Services‎‎ 4 changes history +947 [John d‎ (4×)]
 m   
12:27 (cur | prev) +16 John d talk contribs →‎Statement of Work Tag: Visual edit
 m   
12:27 (cur | prev) +55 John d talk contribs →‎Paperwork for Fabrication Services: made SOW sub heading Tag: Visual edit
 m   
12:25 (cur | prev) +17 John d talk contribs →‎Paperwork for Fabrication Services Tag: Visual edit
     
12:24 (cur | prev) +859 John d talk contribs →‎Paperwork for Fabrication Services: added PPT SOW description Tag: Visual edit: Switched
     12:13  Ion Beam Deposition (Veeco NEXUS) diffhist +205 John d talk contribs →‎Detailed Specifications: "available" sputter targets Tag: Visual edit
     10:16  Contact Alignment Recipes‎‎ 2 changes history +824 [John d‎ (2×)]
     
10:16 (cur | prev) +413 John d talk contribs →‎Negative Resist (MJB-3): added PEB and 5214 info Tag: Visual edit
     
10:16 (cur | prev) +411 John d talk contribs →‎Negative Resist (MA-6): addeed 5214 info Tag: Visual edit
     10:15  Stepper Recipes diffhist +830 John d talk contribs →‎Negative Resist (GCA 6300): added 5214 info Tag: Visual edit
     10:14  Direct-Write Lithography Recipes‎‎ 2 changes history +166 [John d‎ (2×)]
     
10:14 (cur | prev) +19 John d talk contribs →‎Negative Resist (MLA150): udpated 5214 instructions Tag: Visual edit
     
09:46 (cur | prev) +147 John d talk contribs →‎Negative Resist (MLA150): link to az5214 basic process Tag: Visual edit
N    10:12  AZ5214 - Basic Process diffhist +716 John d talk contribs Created page with "AZ5214 is a positive PR to start. If you expose and develop, then the exposed areas develop out like a typical positive PR. File:AZ5214 Fabublox Positive PR schematic.png|n..." Tag: Visual edit
     09:59  (Upload log) [John d‎ (2×)]
     
09:59 John d talk contribs uploaded File:AZ5214 Fabublox negative schematic.png
     
09:57 John d talk contribs uploaded File:AZ5214 Fabublox Positive PR schematic.png

20 August 2024

     14:58  Lithography Recipes‎‎ 2 changes history +55 [Thibeault‎ (2×)]
     
14:58 (cur | prev) -1 Thibeault talk contribs →‎Process Ranking Table Tag: Visual edit
     
14:57 (cur | prev) +56 Thibeault talk contribs →‎Process Ranking Table Tag: Visual edit

19 August 2024

     17:08  Stepper 2 (AutoStep 200) diffhist +121 John d talk contribs →‎Detailed Specifications: added substrate thickness Tag: Visual edit
     13:13 Deletion log John d talk contribs deleted page File:Profim3D System Photo.png(tool removed)
     11:10  Vacuum Deposition Recipes‎‎ 2 changes history +55 [Thibeault‎ (2×)]
     
11:10 (cur | prev) -4 Thibeault talk contribs →‎Deposition Tools/Materials Table Tag: Visual edit
     
11:10 (cur | prev) +59 Thibeault talk contribs →‎Deposition Tools/Materials Table Tag: Visual edit
     11:05  Sputtering Recipes diffhist +86 Thibeault talk contribs →‎Materials Table (Sputter 5) Tag: Visual edit

15 August 2024

     15:33  Template:News‎‎ 3 changes history +11 [John d‎ (3×)]
 m   
15:33 (cur | prev) +8 John d talk contribs →‎NanoFab staff awarded Goleta's Innovator of the Year 2023
     
15:33 (cur | prev) +1 John d talk contribs →‎RIE#3 Removed
 m   
15:33 (cur | prev) +2 John d talk contribs →‎RIE#3 Removed
     15:32  Template:Announcements‎‎ 3 changes history -255 [John d‎ (3×)]
 m   
15:32 (cur | prev) 0 John d talk contribs moved unaxis to top
     
15:32 (cur | prev) -41 John d talk contribs Unaxis UP
     
09:07 (cur | prev) -214 John d talk contribs ebl up
     14:33  Lithography Recipes‎‎ 4 changes history +51 [Thibeault‎ (4×)]
     
14:33 (cur | prev) 0 Thibeault talk contribs →‎Photolithography Recipes Tag: Visual edit
     
14:32 (cur | prev) +3 Thibeault talk contribs →‎Photolithography Recipes Tag: Visual edit
     
14:28 (cur | prev) +24 Thibeault talk contribs →‎Photolithography Recipes Tag: Visual edit
     
14:18 (cur | prev) +24 Thibeault talk contribs →‎Photolithography Recipes Tag: Visual edit
     14:14  Template:Rl/doc diffhist +1 Thibeault talk contribs
     14:13  Template:Rl diffhist +1 Thibeault talk contribs
     11:57  Noah Dutra‎‎ 3 changes history +2 [Noahdutra‎ (3×)]
     
11:57 (cur | prev) -8 Noahdutra talk contribs Tag: Visual edit
     
11:56 (cur | prev) +2 Noahdutra talk contribs Tag: Visual edit
     
11:55 (cur | prev) +8 Noahdutra talk contribs Tag: Visual edit
     09:41  Process Group Interns diffhist +91 John d talk contribs added haley h Tag: Visual edit
     07:52  Gopikrishnan G M diffhist +1,634 Gopimeena talk contribs →‎About: Updated Gopi's personal page Tag: Visual edit

14 August 2024

     18:03  Noah Dutra diffhist +1,321 Noahdutra talk contribs added descriptions Tag: Visual edit
     18:01  Dry Etching Recipes diffhist +3 Ffoong talk contribs →‎Dry Etching Tools/Materials Table Tag: Visual edit
     17:58  Template:Rl/doc diffhist +354 Thibeault talk contribs
     17:54  Lithography Recipes‎‎ 2 changes history +6 [Thibeault‎ (2×)]
     
17:54 (cur | prev) +3 Thibeault talk contribs →‎Photolithography Recipes Tag: Visual edit
     
17:51 (cur | prev) +3 Thibeault talk contribs →‎Photolithography Recipes
     17:49  Template:Rl‎‎ 6 changes history +5 [Thibeault‎ (6×)]
     
17:49 (cur | prev) +5 Thibeault talk contribs
     
17:47 (cur | prev) +3 Thibeault talk contribs
 m   
17:45 (cur | prev) 0 Thibeault talk contribs Reverted edits by Thibeault (talk) to last revision by Zwarburg Tag: Rollback
     
17:44 (cur | prev) -3 Thibeault talk contribs
     
17:43 (cur | prev) 0 Thibeault talk contribs Undo revision 162238 by Thibeault (talk) Tag: Undo
     
17:43 (cur | prev) 0 Thibeault talk contribs Undo revision 162239 by Thibeault (talk) Tag: Undo