== Fabrication Tracking and Process Design ==
Designing experiments, tracking your fabrication steps/process improvements, and keeping track of your results are key to achieving repeatable and improved results!

See this tutorial for example Travelers, Design of Experiments, and Manufacturing Execution Systems:

* [[Processing - How Do I…?#Experiment%20Setup|'''Processing | Experiment Setup''']]

{| class="wikitable"
|+Examples of Trello + Google Drive for tracking fabrication jobs
|[[File:Trello - Example Job Cards.png|alt=Trello - Example Job Cards screenshot|none|thumb|367x367px|Tracking to-do and completed tasks.]][[File:Google Drive - Example Job Folder.png|alt=Google Drive - Example Job Folder screenshot|none|thumb|327x327px|Example Job Folder on Google Drive with in-process traveler, microscope/SEM images, testing results etc.]]
|[[File:Trello - example job card.png|alt=Trello - example job card screenshot|none|thumb|504x504px|Example job card for a fabrication run.]]
|}


== CAD/Drawing Mask Plates ==
== CAD/Drawing Mask Plates ==

Revision as of 16:18, 5 June 2025

The following are various tutorials from our NanoFab Wiki, collected here for your convenience.

<hr\>

Fabrication Tracking and Process Design

Designing experiments, tracking your fabrication steps/process improvements, and keeping track of your results are key to achieving repeatable and improved results!

See this tutorial for example Travelers, Design of Experiments, and Manufacturing Execution Systems:

Examples of Trello + Google Drive for tracking fabrication jobs
Trello - Example Job Cards screenshot
Tracking to-do and completed tasks.
Google Drive - Example Job Folder screenshot
Example Job Folder on Google Drive with in-process traveler, microscope/SEM images, testing results etc.
Trello - example job card screenshot
Example job card for a fabrication run.

CAD/Drawing Mask Plates

Here are pages to help you design your devices in drawing programs, and make photomasks (aka. "masks" or "reticles") for various systems in our lab.
screenshot of KLayout view of Device_Layout
KLayout: example CAD file.

Microfabrication CAD drawings are simple 2D drawings with layers, even though they are intended to become 3D devices through the fabrication process. The fabrication is all top-down, hence only 2D patterning is used.

Stepper Mask Tutorials

Schematic of stepper blocking off adjacent Images on reticle and exposure onto different wafer locations.
Click for Stepper Reticle Tutorial Stepper Reticle Patterns (“images”) can optionally be much more sophisticated and flexible than contact plates.

Mask Making Guidelines

Info for mask/CAD layout for specific tools.

Lithography Tutorials