Tutorials: Difference between revisions

From UCSB Nanofab Wiki
Jump to navigation Jump to search
Content deleted Content added
 
(6 intermediate revisions by the same user not shown)
Line 3: Line 3:
__TOC__
__TOC__


⚫
== General Fabrication ==

⚫
* [[Processing - How Do I…?]] ← This page attempts to list common solutions to fabrication issues our lab users often run into.
* [https://drive.google.com/file/d/1B-Xg254T-RdALisnms0jvpJQ34i5TNXN/view Design of Experiments: Taguchi/L9 DOE methods] - [[Gopikrishnan G M|Gopi]] explains how to identify trends in your process, using multi-variable experiments (to minimize the number of experiments). Do this when you don't have a good physical understanding of how the process variables interact.
== Fabrication Tracking and Process Design ==
== Fabrication Tracking and Process Design ==
Designing experiments, tracking your fabrication steps/process improvements, and keeping track of your results are key to achieving repeatable and improved results!
Designing experiments, tracking your fabrication steps/process improvements, and keeping track of your results are key to achieving repeatable and improved results!


⚫
[[Processing - How Do I…?#Experiment%20Setup|<big>'''Processing: Experiment Setup'''</big>]]
See this tutorial for example Travelers, Design of Experiments, and Manufacturing Execution Systems:

See the above ↑ tutorial pages for examples of:


* [[Processing - How Do I…?#Travelers (aka. RunCards, Process Followers, Work Instructions)|Process Travelers/RunCards/Followers]] - ''Write your process and track what you <u>actually</u> did during the fab''
⚫
* [[Processing - How Do I…?#Experiment%20Setup|'''Processing | Experiment Setup''']]
* [[Processing - How Do I…?#Design of Experiments (DOE)|Design of Experiments]] - ''Develop/optimize a fab step''
* [[Processing - How Do I…?#Tracking your processes|Manufacturing Execution Systems]] - ''Track all your designs, fab runs and experiment results, so you can iterate.''


{| class="wikitable"
{| class="wikitable"
Line 25: Line 33:
* [[Calculators + Utilities#CAD%20Files%20%26%20Templates|Calculators + Utilities > CAD Files & Templates]] - example GDS/OAS files for various useful structures (alignment marks, verniers, fonts etc)
* [[Calculators + Utilities#CAD%20Files%20%26%20Templates|Calculators + Utilities > CAD Files & Templates]] - example GDS/OAS files for various useful structures (alignment marks, verniers, fonts etc)


== Stepper Mask Tutorials ==
== Mask Making Guidelines ==
⚫
''Info for mask/CAD layout for specific tools.''

==== General ====
⚫
* [[Photomask Ordering Procedure for UCSB Users]] - see this page for how to submit your order into the purchasing system.
* See [[Tutorials#CAD/Drawing Mask Plates|CAD tutorials above]] for layout tips and examples.
* [[Tutorial - How Photomasks are Made]] - this will help you submit your mask orders and clear up common misconceptions.

==== Stepper Mask Tutorials ====
[[File:Stepper Reticle Tutorial - Reticle Masking Schematic.png|alt=Schematic of stepper blocking off adjacent Images on reticle and exposure onto different wafer locations.|thumb|'''[https://wiki.nanofab.ucsb.edu/w/images/c/cb/Demis_D_John_-_Stepper_Reticle_Layout_vs_Wafer_Layout.pdf Click for Stepper Reticle Tutorial]''' Stepper Reticle Patterns (“images”) can optionally be much more sophisticated and flexible than contact plates.|link=https://wiki.nanofab.ucsb.edu/w/images/c/cb/Demis_D_John_-_Stepper_Reticle_Layout_vs_Wafer_Layout.pdf]]
[[File:Stepper Reticle Tutorial - Reticle Masking Schematic.png|alt=Schematic of stepper blocking off adjacent Images on reticle and exposure onto different wafer locations.|thumb|'''[https://wiki.nanofab.ucsb.edu/w/images/c/cb/Demis_D_John_-_Stepper_Reticle_Layout_vs_Wafer_Layout.pdf Click for Stepper Reticle Tutorial]''' Stepper Reticle Patterns (“images”) can optionally be much more sophisticated and flexible than contact plates.|link=https://wiki.nanofab.ucsb.edu/w/images/c/cb/Demis_D_John_-_Stepper_Reticle_Layout_vs_Wafer_Layout.pdf]]


Line 31: Line 47:
* '''[[Stepper Reticle Layout (Advanced) - Complex Experiments and Variations]]''' - If you need many design variations on your wafer.
* '''[[Stepper Reticle Layout (Advanced) - Complex Experiments and Variations]]''' - If you need many design variations on your wafer.


==== Steppers ====
== Mask Making Guidelines ==
⚫
* [[Stepper Mask-Making Guidelines (Generic)|Stepper Mask-Making Guidelines]] - Info needed to design and order a reticle for our Stepper systems.
⚫
''Info for mask/CAD layout for specific tools.''
⚫
* [[Photomask Ordering Procedure for UCSB Users]] - see this page for how to submit your order into the purchasing system.

⚫
* [[Stepper Mask-Making Guidelines (Generic)|'''Stepper Mask-Making Guidelines''']] - Info needed to design and order a reticle for our Stepper systems.
* [https://docs.google.com/document/d/1b9YT11RPsl-UlLvN74hrQvG01OcYDL16r6I5lPOlBEo/edit?usp=sharing ASML-specific Mask Making Guidelines (Private)] - More detailed info to design and order a reticle for this specific ASML system.
* [https://docs.google.com/document/d/1b9YT11RPsl-UlLvN74hrQvG01OcYDL16r6I5lPOlBEo/edit?usp=sharing ASML-specific Mask Making Guidelines (Private)] - More detailed info to design and order a reticle for this specific ASML system.
** ''Access is restricted to trained users only by ASML's requirement - please contact [[Demis D. John|tool supervisor]] for access.''
** ''Access is restricted to trained users only by ASML's requirement - please contact [[Demis D. John|tool supervisor]] for access.''
Line 41: Line 54:
* [[Autostep 200 Mask Making Guidance]] - information on designing and ordering your photomasks for the GCA AutoStep 200.
* [[Autostep 200 Mask Making Guidance]] - information on designing and ordering your photomasks for the GCA AutoStep 200.
* [[GCA 6300 Mask Making Guidance]] (''Work in progress'') - GCA 6300 Stepper
* [[GCA 6300 Mask Making Guidance]] (''Work in progress'') - GCA 6300 Stepper

==== Contact Aligners ====
* [[Mask Making Guidelines for Contact Aligners|Mask Making Guidelines - Contact Masks]] - for the MJB-3 & MA6 Contact Aligners
* [[Mask Making Guidelines for Contact Aligners|Mask Making Guidelines - Contact Masks]] - for the MJB-3 & MA6 Contact Aligners

==== Direct-Write ====
* [[MLA150 - Design Guidelines]] - for the Heidelberg MLA150 Direct-Writer
* [[MLA150 - Design Guidelines]] - for the Heidelberg MLA150 Direct-Writer


Line 47: Line 64:
* [[Lithography Calibration - Analyzing a Focus-Exposure Matrix|Lithography Calibration - Analyzing a Focus-Exposure Matrix (FEM)]] - Projection litho systems (steppers, direct-writers) usually require a lithography calibration, using a Focus-Exposure Matrix/Array (FEM/FEA).
* [[Lithography Calibration - Analyzing a Focus-Exposure Matrix|Lithography Calibration - Analyzing a Focus-Exposure Matrix (FEM)]] - Projection litho systems (steppers, direct-writers) usually require a lithography calibration, using a Focus-Exposure Matrix/Array (FEM/FEA).
*{{fl|Liftoff-Techniques.pdf|Lift-Off Description/Tutorial}} - How it works, process limits and considerations for designing your process.
*{{fl|Liftoff-Techniques.pdf|Lift-Off Description/Tutorial}} - How it works, process limits and considerations for designing your process.

⚫
== General Fabrication ==

⚫
* [[Processing - How Do I…?]] ← This page attempts to list common solutions to fabrication issues our lab users often run into.

Latest revision as of 01:29, 13 June 2026

The following are various tutorials from our NanoFab Wiki, collected here for your convenience.

General Fabrication

  • Processing - How Do I…? ← This page attempts to list common solutions to fabrication issues our lab users often run into.
  • Design of Experiments: Taguchi/L9 DOE methods - Gopi explains how to identify trends in your process, using multi-variable experiments (to minimize the number of experiments). Do this when you don't have a good physical understanding of how the process variables interact.

Fabrication Tracking and Process Design

Designing experiments, tracking your fabrication steps/process improvements, and keeping track of your results are key to achieving repeatable and improved results!

Processing: Experiment Setup

See the above ↑ tutorial pages for examples of:

Examples of Trello + Google Drive for tracking fabrication jobs
Trello - Example Job Cards screenshot
Tracking to-do and completed tasks.
Google Drive - Example Job Folder screenshot
Example Job Folder on Google Drive with in-process traveler, microscope/SEM images, testing results etc.
Trello - example job card screenshot
Example job card for a fabrication run.

CAD/Drawing Mask Plates

Here are pages to help you design your devices in drawing programs, and make photomasks (aka. "masks" or "reticles") for various systems in our lab.
screenshot of KLayout view of Device_Layout
KLayout: example CAD file.

Microfabrication CAD drawings are simple 2D drawings with layers, even though they are intended to become 3D devices through the fabrication process. The fabrication is all top-down, hence only 2D patterning is used.

Mask Making Guidelines

Info for mask/CAD layout for specific tools.

General

Stepper Mask Tutorials

Schematic of stepper blocking off adjacent Images on reticle and exposure onto different wafer locations.
Click for Stepper Reticle Tutorial Stepper Reticle Patterns (“images”) can optionally be much more sophisticated and flexible than contact plates.

Steppers

Contact Aligners

Direct-Write

Lithography Tutorials