Main public logs
Jump to navigation
Jump to search
Combined display of all available logs of UCSB Nanofab Wiki. You can narrow down the view by selecting a log type, the username (case-sensitive), or the affected page (also case-sensitive).
- 19:28, 14 May 2025 Sawyer l talk contribs created page File:Ultron 1042R-B Film Specs.pdf
- 19:28, 14 May 2025 Sawyer l talk contribs uploaded File:Ultron 1042R-B Film Specs.pdf
- 19:26, 14 May 2025 Sawyer l talk contribs created page File:ADT SOP Rev K.pdf
- 19:26, 14 May 2025 Sawyer l talk contribs uploaded File:ADT SOP Rev K.pdf
- 03:22, 13 May 2025 Jcrode talk contribs changed group membership for Mitchell b from staff and administrator to staff, administrator and interface administrator
- 23:29, 8 May 2025 John d talk contribs moved page CAD and Photomask Layout to Tutorials (purpose of the page changed)
- 16:02, 29 April 2025 John d talk contribs created page CAD and Photomask Layout (pasted lins to various mask palges across the wiki) Tag: Visual edit
- 01:48, 29 April 2025 John d talk contribs created page File:ASML Reticle Programming Params - DEMIS-DOE v1.xlsx (Stepper reticle tutorial - programming sheet for DOE layouts (Demis D John))
- 01:48, 29 April 2025 John d talk contribs uploaded File:ASML Reticle Programming Params - DEMIS-DOE v1.xlsx (Stepper reticle tutorial - programming sheet for DOE layouts (Demis D John))
- 01:47, 29 April 2025 John d talk contribs created page File:CAD Tutorial for ASML Reticle v2 DEMIS-DOE.OAS (Stepper reticle tutorial OAS file (Demis D John))
- 01:47, 29 April 2025 John d talk contribs uploaded File:CAD Tutorial for ASML Reticle v2 DEMIS-DOE.OAS (Stepper reticle tutorial OAS file (Demis D John))
- 01:44, 29 April 2025 John d talk contribs created page Stepper Reticle Layout (Advanced) - Complex Experiments and Variations (initial page) Tag: Visual edit
- 01:26, 29 April 2025 John d talk contribs created page File:Stepper Reticle Layout Tutorial - Wafer layout with variations.png
- 01:26, 29 April 2025 John d talk contribs uploaded File:Stepper Reticle Layout Tutorial - Wafer layout with variations.png
- 01:24, 29 April 2025 John d talk contribs created page File:Stepper Reticle Layout Tutorial - Reticle layout with variations.png
- 01:24, 29 April 2025 John d talk contribs uploaded File:Stepper Reticle Layout Tutorial - Reticle layout with variations.png
- 19:13, 16 April 2025 Sawyer l talk contribs created page File:ICP -2 SOP Rev A.pdf
- 19:13, 16 April 2025 Sawyer l talk contribs uploaded File:ICP -2 SOP Rev A.pdf
- 19:11, 16 April 2025 Sawyer l talk contribs created page File:Manual Wafer Transfer.pdf
- 19:11, 16 April 2025 Sawyer l talk contribs uploaded File:Manual Wafer Transfer.pdf
- 19:07, 16 April 2025 Sawyer l talk contribs created page File:ICP -2 Gas Change SOP Rev B.pdf
- 19:07, 16 April 2025 Sawyer l talk contribs uploaded File:ICP -2 Gas Change SOP Rev B.pdf
- 17:43, 15 April 2025 User account Seongeun Kang talk contribs was created
- 20:15, 12 April 2025 John d talk contribs created page File:Edge bead Removal on MA6 - IMG 5625 - placed on wafer.jpg
- 20:15, 12 April 2025 John d talk contribs uploaded File:Edge bead Removal on MA6 - IMG 5625 - placed on wafer.jpg
- 20:14, 12 April 2025 John d talk contribs created page File:Edge bead Removal on MA6 - IMG 5626 - place on wafer.jpg
- 20:14, 12 April 2025 John d talk contribs uploaded File:Edge bead Removal on MA6 - IMG 5626 - place on wafer.jpg
- 20:13, 12 April 2025 John d talk contribs created page File:Edge bead Removal on MA6 - IMG 5624 - cassette location.jpg
- 20:13, 12 April 2025 John d talk contribs uploaded File:Edge bead Removal on MA6 - IMG 5624 - cassette location.jpg
- 20:12, 12 April 2025 John d talk contribs created page File:Edge bead Removal on MA6 - IMG 5623 - vidmar drawers.jpg
- 20:12, 12 April 2025 John d talk contribs uploaded File:Edge bead Removal on MA6 - IMG 5623 - vidmar drawers.jpg
- 20:06, 12 April 2025 John d talk contribs moved page ASML DUV: Edge Bead Removal via Photolithography to Edge Bead Removal via Photolithography for 4-inch Wafers (make title generic to I-line and DUV PR's)
- 20:27, 7 April 2025 John d talk contribs created page File:Microscope DIC-Nomarski Example v1.jpg
- 20:27, 7 April 2025 John d talk contribs uploaded File:Microscope DIC-Nomarski Example v1.jpg
- 20:15, 7 April 2025 John d talk contribs created page File:Dark Field Microscopy - High Particle Count example 2025-03-25 W1 particle check Demis.jpg
- 20:15, 7 April 2025 John d talk contribs uploaded File:Dark Field Microscopy - High Particle Count example 2025-03-25 W1 particle check Demis.jpg
- 20:10, 7 April 2025 John d talk contribs created page File:Dark Field Microscopy explanation v1.jpg
- 20:10, 7 April 2025 John d talk contribs uploaded File:Dark Field Microscopy explanation v1.jpg
- 18:28, 7 April 2025 John d talk contribs deleted page MLA150 - Focus-Exposure Matrix ("Series" mode) (empty)
- 14:55, 14 March 2025 Barreraz talk contribs created page File:IMG 7361.jpg
- 14:55, 14 March 2025 Barreraz talk contribs uploaded File:IMG 7361.jpg
- 17:10, 13 March 2025 Biljana talk contribs created page File:Thermal Evaporator2-Plot.png
- 17:10, 13 March 2025 Biljana talk contribs uploaded File:Thermal Evaporator2-Plot.png
- 17:04, 13 March 2025 Biljana talk contribs created page File:Thermal Evaprator2-Cold Fixture-Indium Deposition.pdf
- 17:04, 13 March 2025 Biljana talk contribs uploaded File:Thermal Evaprator2-Cold Fixture-Indium Deposition.pdf
- 17:02, 13 March 2025 Biljana talk contribs created page File:Thermal Evaporator2-Normal Fixture- Indium Deposition.pdf
- 17:02, 13 March 2025 Biljana talk contribs uploaded File:Thermal Evaporator2-Normal Fixture- Indium Deposition.pdf
- 16:59, 13 March 2025 Biljana talk contribs created page File:Thermal Evapoartor 2 Indium deposition plot (1).pdf
- 16:59, 13 March 2025 Biljana talk contribs uploaded File:Thermal Evapoartor 2 Indium deposition plot (1).pdf
- 16:58, 13 March 2025 Biljana talk contribs created page File:Wiki-Thermal Evaporator2-Normal Fixture- Indium Deposition.docx