User contributions
Jump to navigation
Jump to search
- 08:46, 14 November 2018 diff hist +231 Calculators + Utilities klayout> draw circles Tag: Visual edit
- 11:17, 9 November 2018 diff hist +135 Tool List →Dry Etch: link to etch monitors, specifically Laser Etch Monitoring page Tag: Visual edit
- 11:14, 9 November 2018 diff hist 0 m Laser Etch Monitoring John d moved page Intellemetrics Laser Etch Monitoring to Laser Etch Monitoring without leaving a redirect: make it generic to all laser etch monitors
- 11:14, 9 November 2018 diff hist +2,080 N Laser Etch Monitoring initial page, overview of laser monitoring, references and links to non-existent (desired) procedures Tag: Visual edit
- 09:08, 9 November 2018 diff hist +195 Template:Announcements deleted Cary500, added FIlmetrics announcements
- 10:35, 2 November 2018 diff hist +69,241 N Lab Rules initial copy/paste, partially formatted headings. Tag: Visual edit
- 09:56, 1 November 2018 diff hist +122 Photoluminescence PL Setup (Custom) Added spectrometer Tag: Visual edit
- 17:45, 29 October 2018 diff hist +225 Atomic Layer Deposition Recipes added temps and plasma/reactant info Tag: Visual edit
- 17:41, 29 October 2018 diff hist +4 Atomic Layer Deposition Recipes →ZnO Deposition (ALD Chamber 1): added approx rate from old notes Tag: Visual edit
- 13:37, 24 October 2018 diff hist +57 Stepper Recipes →Positive Resist (ASML DUV): UV6-0.7 recipe - mentioned replaced by -0.8 Tag: Visual edit
- 10:40, 23 October 2018 diff hist -139 m Wet Etching Recipes deleted test stuff Tag: Visual edit
- 10:38, 23 October 2018 diff hist +84 m Wet Etching Recipes table test Tag: Visual edit
- 10:34, 23 October 2018 diff hist +57 m Wet Etching Recipes example testing Tag: Visual edit
- 10:30, 22 October 2018 diff hist +29 Packaging Recipes →Mounting/Unmounting Samples: corrected tape model # and link to image
- 10:29, 22 October 2018 diff hist 0 m ADT UV-Tape Table 1042R John d moved page ? to ADT UV-Tape Table 1042R without leaving a redirect: give a name to page current
- 07:15, 22 October 2018 diff hist -360 Template:Announcements deleted lab closed
- 14:09, 17 October 2018 diff hist +2,218 N RIE5 - Standard Operating procedure (Cortex Software) pasted Don's SOP's current Tag: Visual edit
- 13:58, 17 October 2018 diff hist +40 RIE 5 (PlasmaTherm) →Documentation: link to new SOP Tag: Visual edit
- 13:49, 17 October 2018 diff hist -36 Packaging Recipes →Cutting Parameters: made header row Tag: Visual edit
- 13:47, 17 October 2018 diff hist +707 N Logitech WBS7 - Procedure for Wax Mounting with Spin-On Crystalbond pasted draft procedure
- 13:47, 17 October 2018 diff hist -513 Packaging Recipes moved logitech procedure to separate page. Tag: Visual edit
- 12:19, 17 October 2018 diff hist 0 m Editing Tutorials →Inserting images into a page: adjut recommended image height
- 12:18, 17 October 2018 diff hist +119 m Editing Tutorials →Inserting images into a page: moved floating image to end of sentence
- 12:15, 17 October 2018 diff hist +1,717 Editing Tutorials →Inserting images into a page: added instructions for inserting images Tag: Visual edit
- 11:33, 17 October 2018 diff hist +13 N File:MacOS - Happy Mac.png current
- 17:33, 16 October 2018 diff hist +48 Atomic Layer Deposition Recipes →Al O deposition (ALD CHAMBER 3): converted to regular subscripts, indented each recipe param Tag: Visual edit
- 14:40, 16 October 2018 diff hist +7 Template:Announcements lab closed thurs, deleted RIE5 SiCl4
- 14:39, 16 October 2018 diff hist -55 Template:Announcements updates to RIE5, PECVD1
- 09:15, 16 October 2018 diff hist +59 Dicing Saw (ADT) added sections for SOP, Detials Tag: Visual edit
- 09:14, 16 October 2018 diff hist +366 Wafer Bonder (Logitech WBS7) added link to recipes, short About statement. Tag: Visual edit
- 09:12, 16 October 2018 diff hist +893 Packaging Recipes added Logitech Wafer bonder section, initial draft of procedure for wax mounting Tag: Visual edit
- 09:03, 16 October 2018 diff hist +648 Tube Furnace AlGaAs Oxidation (Lindberg) added Description, and blanks secitons for Procedures/Recipes Tag: Visual edit
- 08:58, 16 October 2018 diff hist +287 Dicing Saw (ADT) linked to Dicing Recipes Tag: Visual edit
- 22:28, 15 October 2018 diff hist +1,228 N Packaging Recipes inital pages Tag: Visual edit
- 22:01, 15 October 2018 diff hist +36 MediaWiki:Sidebar added link to Packaging recipes
- 21:44, 15 October 2018 diff hist +228 m Ion Beam Deposition (Veeco NEXUS) →Detailed Specifications: red-link for calibration method Tag: Visual edit
- 21:41, 15 October 2018 diff hist +141 m Ion Beam Deposition (Veeco NEXUS) →Detailed Specifications: added TiN, Argon sample cleaning, nIR DBRs Tag: Visual edit
- 14:52, 15 October 2018 diff hist +2,102 Thermal Processing Recipes Updated thermal ox Recipe names, added Logitech Bonder, Finetech Bonder, Tystar AlGaAs, Lindberg AlGaAs basic info. Tag: Visual edit
- 10:48, 12 October 2018 diff hist +75 PECVD Recipes →PECVD 1 (PlasmaTherm 790): note about software upgrade Tag: Visual edit
- 23:25, 10 October 2018 diff hist -24 m Step Profilometer (KLA Tencor P-7) deleted erroneous "email" field from {tool} template
- 23:24, 10 October 2018 diff hist -2 Template:Tool update Brian Linng's email
- 23:19, 10 October 2018 diff hist +89 Probe Station & Curve Tracer →Equipment Specifications: included Windows PC & scripting environments Tag: Visual edit
- 23:18, 10 October 2018 diff hist +217 Probe Station & Curve Tracer →Equipment Specifications: deleted HP ParamAnalyzer Tag: Visual edit
- 23:16, 10 October 2018 diff hist -62 Tool List →Topographical Metrology: removed Rudolph Ellips & old Dektak Tag: Visual edit
- 23:13, 10 October 2018 diff hist +459 Filmetrics F40-UV Microscope-Mounted added capabilities section Tag: Visual edit
- 23:06, 10 October 2018 diff hist +161 Ellipsometer (Rudolph) note that tool has been removed current
- 13:51, 5 October 2018 diff hist +72 m ASML 5500: Recovering from an Error minor wording Tag: Visual edit
- 08:34, 5 October 2018 diff hist +1,259 ASML Stepper 3 Error Recovery, Troubleshooting and Calibration moved some procedures onto this one common page Tag: Visual edit
- 08:33, 5 October 2018 diff hist -348 Stepper 3 (ASML DUV) →Troubleshooting and Recovery: removed uneeded links Tag: Visual edit
- 08:03, 5 October 2018 diff hist +184 ASML Stepper 3 Error Recovery, Troubleshooting and Calibration link to wafer recovery page Tag: Visual edit