Recent changes

Jump to navigation Jump to search

Track the most recent changes to the wiki on this page.

Recent changes options Show last 50 | 100 | 250 | 500 changes in last 1 | 3 | 7 | 14 | 30 days
Hide registered users | Hide anonymous users | Hide my edits | Hide bots | Show minor edits
Show new changes starting from 11:51, 23 June 2024
   
List of abbreviations:
N
This edit created a new page (also see list of new pages)
m
This is a minor edit
b
This edit was performed by a bot
(±123)
The page size changed by this number of bytes

20 June 2024

     08:30  Fluorine ICP Etcher (PlasmaTherm/SLR Fluorine ICP) diffhist +777 John d talk contribs →‎Recipes: added process control data section Tag: Visual edit: Switched

14 June 2024

     17:01  Template:Announcements‎‎ 2 changes history -74 [Mehalana v‎ (2×)]
     
17:01 (cur | prev) -281 Mehalana v talk contribs →‎(JEOL JBX-6300FS) - 06/13: System still DOWN
     
16:59 (cur | prev) +207 Mehalana v talk contribs
     09:59  Fluorine ICP Etcher (PlasmaTherm/SLR Fluorine ICP) diffhist +20 John d talk contribs added tool model to toolinfo

13 June 2024

     17:16  Template:Announcements‎‎ 2 changes history -1,053 [Mehalana v‎ (2×)]
     
17:16 (cur | prev) +316 Mehalana v talk contribs
     
17:15 (cur | prev) -1,369 Mehalana v talk contribs

6 June 2024

     15:20  E-Beam 4 (CHA) diffhist -6 Barreraz talk contribs →‎Documentation Tag: Visual edit
     15:19  (Upload log) [Sawyer l‎; Barreraz‎ (2×)]
     
15:19 Barreraz talk contribs uploaded File:EB4 Operating Instructions 6-6-24.pdf
     
15:07 Barreraz talk contribs uploaded File:EB-1 operation instructions 6-6-24.pdf
     
14:08 Sawyer l talk contribs uploaded File:Post Dicing Tape Expansion SOP.pdf
     15:08  E-Beam 1 (Sharon) diffhist 0 Barreraz talk contribs →‎Documentation Tag: Visual edit
     14:10  Dicing Saw (ADT) diffhist -8 Sawyer l talk contribs Added Tape expansion SOP Tag: Visual edit

5 June 2024

     10:59  MLA150 - Troubleshooting diffhist +3 John d talk contribs →‎Solutions for small substrates: --> sols for ALL substrate types Tag: Visual edit

4 June 2024

     15:59  Template:Announcements diffhist +408 Mehalana v talk contribs
     15:27  PECVD Recipes‎‎ 6 changes history +960 [Biljana‎ (6×)]
     
15:27 (cur | prev) +249 Biljana talk contribs →‎Low Stress Si3N4 [ICP-PECVD]
     
15:25 (cur | prev) +229 Biljana talk contribs →‎Si3N4 [ICP-PECVD]
     
15:24 (cur | prev) -1 Biljana talk contribs →‎High Deposition Rate SiO2 [ICP-PECVD]
     
15:24 (cur | prev) +241 Biljana talk contribs →‎High Deposition Rate SiO2 [ICP-PECVD]
     
15:22 (cur | prev) +31 Biljana talk contribs →‎Low Deposition Rate SiO2 [ICP-PECVD]
     
15:21 (cur | prev) +211 Biljana talk contribs →‎Low Deposition Rate SiO2 [ICP-PECVD]
     12:32  E-Beam 1 (Sharon)‎‎ 2 changes history -321 [Barreraz‎ (2×)]
     
12:32 (cur | prev) +4 Barreraz talk contribs →‎Documentation Tag: Visual edit
     
10:19 (cur | prev) -325 Barreraz talk contribs →‎About Tag: Visual edit
     12:31  (Upload log) [Barreraz‎ (3×)]
     
12:31 Barreraz talk contribs uploaded File:EB1 Rotation Fixture SOP 6-4-24.pdf
     
10:26 Barreraz talk contribs uploaded a new version of File:E-beam1.jpg
     
10:22 Barreraz talk contribs uploaded File:IMG 5450.jpg
     10:26  File:IMG 5450.jpg diffhist +3 Barreraz talk contribs Tag: Visual edit

3 June 2024

     14:44  (Upload log) [Barreraz‎ (2×)]
     
14:44 Barreraz talk contribs uploaded a new version of File:EB-3 operation instructions 5-22-24 V45.47.pdf
     
14:43 Barreraz talk contribs uploaded File:EB-1 operation instructions 6-3-24.pdf
     14:44  E-Beam 1 (Sharon) diffhist -1 Barreraz talk contribs →‎Documentation Tag: Visual edit

1 June 2024

     13:32  Template:Announcements‎‎ 2 changes history +440 [Mehalana v‎ (2×)]
     
13:32 (cur | prev) -77 Mehalana v talk contribs
     
13:29 (cur | prev) +517 Mehalana v talk contribs

31 May 2024

     15:53  Template:Tool2 diffhist -3 John d talk contribs Remove "N/A" when "recipes" section is not shown
     15:48  (Upload log) [John d‎ (2×)]
     
15:48 John d talk contribs uploaded a new version of File:DSEiii Example Bosch Etch 02.jpg(Added UCSB NanoFab watermark)
     
15:44 John d talk contribs uploaded File:DSEiii Example Bosch Etch 02.jpg
     15:46  DSEIII (PlasmaTherm/Deep Silicon Etcher) diffhist +615 John d talk contribs added beter Bosch example showing striations Tag: Visual edit

30 May 2024

     10:36  Template:Announcements diffhist +940 Mehalana v talk contribs

29 May 2024

     10:22  Template:Announcements diffhist -435 John d talk contribs removed old ASML annc, fixed sig on new ASMl annc

28 May 2024

     08:54  Plasma Clean (YES EcoClean) diffhist -1 Sawyer l talk contribs SOP Rev Tag: Visual edit
     08:53 Upload log Sawyer l talk contribs uploaded File:YES SOP Rev F.pdf(Revised)