Lithography Recipes: Difference between revisions

From UCSB Nanofab Wiki
Jump to navigation Jump to search
Content deleted Content added
→Photolithography Recipes: linked to all PR datasheets
Line 72: Line 72:
{{LithRecipe Table}}
{{LithRecipe Table}}
|- bgcolor="EEFFFF"<!-- This is the Row color: lightblue -->
|- bgcolor="EEFFFF"<!-- This is the Row color: lightblue -->
| bgcolor="#D0E7FF" align="center" |AZ4110
| bgcolor="#D0E7FF" align="center" |[[:File:AXP4000pb-Datasheet.pdf|AZ4110]]
|{{rl|Contact_Alignment_Recipes|Positive Resist (MJB-3)}}
|{{rl|Contact_Alignment_Recipes|Positive Resist (MJB-3)}}
|{{rl|Contact_Alignment_Recipes|Positive Resist (MA-6)}}
|{{rl|Contact_Alignment_Recipes|Positive Resist (MA-6)}}
Line 80: Line 80:
|
|
|-<!-- This is a White row color -->
|-<!-- This is a White row color -->
| bgcolor="#D0E7FF" align="center" |AZ4210
| bgcolor="#D0E7FF" align="center" |[[Media:AXP4000pb-Datasheet.pdf|AZ4210]]
|{{rl|Contact_Alignment_Recipes|Positive Resist (MJB-3)}}
|{{rl|Contact_Alignment_Recipes|Positive Resist (MJB-3)}}
|{{rl|Contact_Alignment_Recipes|Positive Resist (MA-6)}}
|{{rl|Contact_Alignment_Recipes|Positive Resist (MA-6)}}
Line 88: Line 88:
|
|
|- bgcolor="EEFFFF"
|- bgcolor="EEFFFF"
| bgcolor="#D0E7FF" align="center" |AZ4330RS
| bgcolor="#D0E7FF" align="center" |[[Media:AXP4000pb-Datasheet.pdf|AZ4330RS]]
|{{rl|Contact_Alignment_Recipes|Positive Resist (MJB-3)}}
|{{rl|Contact_Alignment_Recipes|Positive Resist (MJB-3)}}
|{{rl|Contact_Alignment_Recipes|Positive Resist (MA-6)}}
|{{rl|Contact_Alignment_Recipes|Positive Resist (MA-6)}}
Line 96: Line 96:
|
|
|-
|-
| bgcolor="#D0E7FF" align="center" |AZ4620
| bgcolor="#D0E7FF" align="center" |[[Media:Az p4620 photoresist data package.pdf|AZ4620]]
|
|
|
|
Line 104: Line 104:
|A
|A
|- bgcolor="EEFFFF"
|- bgcolor="EEFFFF"
| bgcolor="#D0E7FF" align="center" |OCG 825-35CS
| bgcolor="#D0E7FF" align="center" |[[Media:OCG825-Positive-Resist-Datasheet.pdf|OCG 825-35CS]]
| A
| A
| A
| A
Line 120: Line 120:
|
|
|- bgcolor="EEFFFF"
|- bgcolor="EEFFFF"
| bgcolor="#D0E7FF" align="center" |SPR 955 CM-0.9
| bgcolor="#D0E7FF" align="center" |[[Media:SPR955-Positive-Resist-Datasheet.pdf|SPR 955 CM-0.9]]
|A
|A
|{{rl|Contact_Alignment_Recipes|Positive Resist (MA-6)}}
|{{rl|Contact_Alignment_Recipes|Positive Resist (MA-6)}}
Line 128: Line 128:
|
|
|-
|-
| bgcolor="#D0E7FF" align="center" |SPR 955 CM-1.8
| bgcolor="#D0E7FF" align="center" |[[Media:SPR955-Positive-Resist-Datasheet.pdf|SPR 955 CM-1.8]]
|A
|A
|A
|A
Line 136: Line 136:
|
|
|- bgcolor="EEFFFF"
|- bgcolor="EEFFFF"
| bgcolor="#D0E7FF" align="center" |SPR 220-3.0
| bgcolor="#D0E7FF" align="center" |[[Media:SPR220-Positive-Resist-Datasheet.pdf|SPR 220-3.0]]
|{{rl|Contact_Alignment_Recipes|Positive Resist (MJB-3)}}
|{{rl|Contact_Alignment_Recipes|Positive Resist (MJB-3)}}
|{{rl|Contact_Alignment_Recipes|Positive Resist (MA-6)}}
|{{rl|Contact_Alignment_Recipes|Positive Resist (MA-6)}}
Line 144: Line 144:
|
|
|-
|-
| bgcolor="#D0E7FF" align="center" |SPR 220-7.0
| bgcolor="#D0E7FF" align="center" |[[Media:SPR220-Positive-Resist-Datasheet.pdf|SPR 220-7.0]]
|{{rl|Contact_Alignment_Recipes|Positive Resist (MJB-3)}}
|{{rl|Contact_Alignment_Recipes|Positive Resist (MJB-3)}}
|{{rl|Contact_Alignment_Recipes|Positive Resist (MA-6)}}
|{{rl|Contact_Alignment_Recipes|Positive Resist (MA-6)}}
Line 152: Line 152:
|
|
|- bgcolor="EEFFFF"
|- bgcolor="EEFFFF"
| bgcolor="#D0E7FF" align="center" |THMR-IP3600 HP D
| bgcolor="#D0E7FF" align="center" |[[Media:3600 D, D2v Spin Speed Curve.pdf|THMR-IP3600 HP D]]
|
|
|
|
Line 160: Line 160:
|A
|A
|-
|-
| bgcolor="#D0E7FF" align="center" |UV6-0.8
| bgcolor="#D0E7FF" align="center" |[[Media:UV6-Positive-Resist-Datasheet.pdf|UV6-0.8]]
|
|
|
|
Line 168: Line 168:
|
|
|- bgcolor="EEFFFF"
|- bgcolor="EEFFFF"
| bgcolor="#D0E7FF" align="center" |UV210-0.3
| bgcolor="#D0E7FF" align="center" |[[Media:UV210-Positive-Resist-Datasheet.pdf|UV210-0.3]]
|
|
|
|
Line 176: Line 176:
|
|
|-
|-
| bgcolor="#D0E7FF" align="center" |UV26-2.5
| bgcolor="#D0E7FF" align="center" |[[Media:UV26-Positive-Resist-Datasheet.pdf|UV26-2.5]]
|
|
|
|
Line 187: Line 187:
{{LithRecipe Table}}
{{LithRecipe Table}}
|-
|-
| bgcolor="#D0E7FF" align="center" |AZ5214-EIR
| bgcolor="#D0E7FF" align="center" |[[Media:AZ5214-Negative-Resist-Datasheet.pdf|AZ5214-EIR]]
|{{rl|Contact_Alignment_Recipes|Negative Resist (MJB-3)}}
|{{rl|Contact_Alignment_Recipes|Negative Resist (MJB-3)}}
|{{rl|Contact_Alignment_Recipes|Negative Resist (MA-6)}}
|{{rl|Contact_Alignment_Recipes|Negative Resist (MA-6)}}
Line 195: Line 195:
|
|
|- bgcolor="EEFFFF"
|- bgcolor="EEFFFF"
| bgcolor="#D0E7FF" align="center" |AZnLOF 2020
| bgcolor="#D0E7FF" align="center" |[[Media:AZnLOF2020-Negative-Resist-Datasheet.pdf|AZnLOF 2020]]
|{{rl|Contact_Alignment_Recipes|Positive Resist (MJB-3)}}
|{{rl|Contact_Alignment_Recipes|Positive Resist (MJB-3)}}
|{{rl|Contact_Alignment_Recipes|Negative Resist (MA-6)}}
|{{rl|Contact_Alignment_Recipes|Negative Resist (MA-6)}}
Line 203: Line 203:
|
|
|-
|-
| bgcolor="#D0E7FF" align="center" |AZnLOF 2035
| bgcolor="#D0E7FF" align="center" |[[Media:AZnLOF2020-Negative-Resist-Datasheet.pdf|AZnLOF 2035]]
| bgcolor="EEFFFF" |A
| bgcolor="EEFFFF" |A
| bgcolor="EEFFFF" |A
| bgcolor="EEFFFF" |A
Line 211: Line 211:
| bgcolor="EEFFFF" |
| bgcolor="EEFFFF" |
|- bgcolor="EEFFFF"
|- bgcolor="EEFFFF"
| bgcolor="#D0E7FF" align="center" |AZnLOF 2070
| bgcolor="#D0E7FF" align="center" |[[Media:AZnLOF2020-Negative-Resist-Datasheet.pdf|AZnLOF 2070]]
|A
|A
|A
|A
Line 219: Line 219:
|
|
|-
|-
| bgcolor="#D0E7FF" align="center" |AZnLOF 5510
| bgcolor="#D0E7FF" align="center" |[[Media:AZnLOF5510-Negative-Resist-Datasheet.pdf|AZnLOF 5510]]
|A
|A
|A
|A
Line 227: Line 227:
|
|
|- bgcolor="EEFFFF"
|- bgcolor="EEFFFF"
| bgcolor="#D0E7FF" align="center" |UVN30-0.8
| bgcolor="#D0E7FF" align="center" |[[Media:UVN-30 - Negative-Resist-Datasheet - Apr 2004.pdf|UVN30-0.8]]
|
|
|
|
Line 235: Line 235:
|
|
|-
|-
| bgcolor="#D0E7FF" align="center" |SU-8 2005,2010, 2015
| bgcolor="#D0E7FF" align="center" |[[Media:SU-8-2015-revA.pdf|SU-8 2005,2010,2015]]
| A
| A
| {{rl|Contact_Alignment_Recipes|Negative Resist (MA-6)}}
| {{rl|Contact_Alignment_Recipes|Negative Resist (MA-6)}}
Line 243: Line 243:
|
|
|- bgcolor="EEFFFF"
|- bgcolor="EEFFFF"
| bgcolor="#D0E7FF" align="center" |SU-8 2075
| bgcolor="#D0E7FF" align="center" |[[Media:SU-8-2075-revA.pdf|SU-8 2075]]
|A
|A
|A
|A
Line 251: Line 251:
|
|
|-
|-
| bgcolor="#D0E7FF" align="center" |NR9-1000,3000,6000PY
| bgcolor="#D0E7FF" align="center" |NR9-[[Media:NR9-1000PY-revA.pdf|1000]],[[Media:NR9-3000PY-revA.pdf|3000]],[[Media:NR9-6000PY-revA.pdf|6000]]PY
|{{rl|Contact_Alignment_Recipes|Positive Resist (MJB-3)}}
|{{rl|Contact_Alignment_Recipes|Positive Resist (MJB-3)}}
|{{rl|Contact_Alignment_Recipes|Positive Resist (MA-6)}}
|{{rl|Contact_Alignment_Recipes|Positive Resist (MA-6)}}
Line 262: Line 262:
{{LithRecipe Table}}
{{LithRecipe Table}}
|-
|-
| bgcolor="#D0E7FF" align="center" |DUV42-P
| bgcolor="#D0E7FF" align="center" |[[Media:DUV42P-Anti-Reflective-Coating.pdf|DUV42-P]]
|
|
|
|
Line 270: Line 270:
|
|
|- bgcolor="EEFFFF"
|- bgcolor="EEFFFF"
| bgcolor="#D0E7FF" align="center" |DS-K101-304
| bgcolor="#D0E7FF" align="center" |[[Media:DS-K101-304-Anti-Reflective-Coating.pdf|DS-K101-304]]
|
|
|
|
Line 330: Line 330:


*{{fl|AXP4000pb-Datasheet.pdf|AZP4000 (AZ4110, AZ4210, AZ4330)}}
*{{fl|AXP4000pb-Datasheet.pdf|AZP4000 (AZ4110, AZ4210, AZ4330)}}
*[[Media:Az p4620 photoresist data package.pdf|AZP4620]]
*{{fl|OCG825-Positive-Resist-Datasheet.pdf|OCG825}}
*{{fl|OCG825-Positive-Resist-Datasheet.pdf|OCG825}}
*{{fl|SPR220-Positive-Resist-Datasheet.pdf|SPR220 (SPR220-3, SPR220-7)}}
*{{fl|SPR220-Positive-Resist-Datasheet.pdf|SPR220 (SPR220-3, SPR220-7)}}

Revision as of 01:03, 19 September 2020

General Information

This page contains information and links to recipes/datasheets spin-coated materials used in the facility.

Table of Contents
Photolithography Processes
  • UV Optical Lithography
    • Photo Lithography Recipe section
      • Has links to starting recipes (spin, bake, exposure, develop etc.) for Contact Aligners, Steppers and Maskless Aligner.
      • Substrate, surface materials, pattern size can often affect process parameters. Users may need to run Focus/Exposure Arrays/Matrix (FEA's/FEM's) with these processes to achieve high-resolution.
    • Stocked Lithography Chemical + Datasheets
      • Lists all stocked photolith. chemicals, PRs, strippers, developers, and links to the chemical's application notes/datasheet, which detail the spin curves and nominal processes.
  • Lift-Off Recipes
    • Verified Recipes for lift-off using various photolith. tools
    • General educational description of this technique and it's limitations/considerations.
  • E-beam Lithography
  • Holography
    • For 1-D and 2-D gratings with 220nm nominal period, available on substrates up to 1 inch square.
    • Recipes for silicon substrates are provided, and have been translated to other substrates by users.
  • Nanoimprinting Resists

Photolithography Chemicals/Materials

  • Underlayers
    • These are used beneath resists for both adhesive purposes and to enable bi-layer lift-off profiles for use with photoresist.
    • Datasheets are provided.
  • Anti-Reflection Coatings:
    • The Photoresist Recipes section contains recipes using these materials.
    • Bottom Anti-Reflection Coatings (BARC) are used in the stepper systems, underneath the resists to eliminate substrate reflections that can affect resolution and repeatability for small, near resolution limited, feature sizes.
    • Datasheets are provided for reference on use of the materials.
  • Contrast Enhancement Materials (CEM)
    • The Photoresist Recipes section contains recipes using these materials.
    • Used for resolution enhancement. Not for use in contact aligners, typically used on I-Line Steppers.
    • Datasheets provided with usage info.
  • Adhesion Promoters
    • These are used to improve wetting of photoresists to your substrate.
    • Datasheets are provided on use of these materials.

Photolithography Recipes

  • R = Recipe is available. Clicking this link will take you to the recipe.
  • A = Material is available for use, but no recipes are provided.


Photolithography Recipes
Contact Aligner Recipes Stepper Recipes Other
Positive Resists SUSS MJB-3 SUSS MA-6 Stepper 1
(GCA 6300)
Stepper 2
(AutoStep 200)
Stepper 3
(ASML DUV)
MLA150
(Heidelberg)
AZ4110 R1 R1 A A
AZ4210 R1 R1 A A
AZ4330RS R1 R1 A A
AZ4620 A
OCG 825-35CS A A A A
SPR 950-0.8 A A A A
SPR 955 CM-0.9 A R1 R1 R1
SPR 955 CM-1.8 A A R1 R1
SPR 220-3.0 R1 R1 R1 R1
SPR 220-7.0 R1 R1 R1 R1
THMR-IP3600 HP D A A A
UV6-0.8 R1
UV210-0.3 R1
UV26-2.5 A
Negative Resists SUSS MJB-3 SUSS MA-6 Stepper 1
(GCA 6300)
Stepper 2
(AutoStep 200)
Stepper 3
(ASML DUV)
MLA150
(Heidelberg)
AZ5214-EIR R1 R1 R1 R1
AZnLOF 2020 R1 R1 R1 R1
AZnLOF 2035 A A A A
AZnLOF 2070 A A A A
AZnLOF 5510 A A R1 R1
UVN30-0.8 R1
SU-8 2005,2010,2015 A R1 A A
SU-8 2075 A A A A
NR9-1000,3000,6000PY R1 R1 A R1
Anti-Reflection Coatings SUSS MJB-3 SUSS MA-6 Stepper 1
(GCA 6300)
Stepper 2
(AutoStep 200)
Stepper 3
(ASML DUV)
MLA150
(Heidelberg)
DUV42-P R1
DS-K101-304 R1
SUSS MJB-3 SUSS MA-6 Stepper 1
(GCA 6300)
Stepper 2
(AutoStep 200)
Stepper 3
(ASML DUV)
MLA150
(Heidelberg)

Lift-Off Recipes

E-Beam Lithography Recipes (JEOL JBX-6300FS)

  • Under Development.

FIB Lithography Recipes (Raith Velion)

To Be Added

Automated Coat/Develop System Recipes (S-Cubed Flexi)

Recipes pre-loaded on the S-Cubed Flexi automated coat/bake/develop system. Only staff may write new recipes, contact the tool supervisor for more info.

To Be Added

Nanoimprinting Recipes

Holography Recipes

Low-K Spin-On Dielectric Recipes

Chemicals Stocked + Datasheets

The following is a list of the lithography chemicals we stock in the lab, with links to the datasheets for each. The datasheets will often have important processing info such as spin-speed vs. thickness curves, typical process parameters, bake temps/times etc.

Positive Photoresists

i-line and broadband

DUV-248nm

Negative Photoresists

i-line and broadband

DUV-248nm

Underlayers
E-beam resists
Nanoimprinting
Contrast Enhancement Materials
Anti-Reflection Coatings
Adhesion Promoters
Spin-On Dielectrics

Low-K Spin-On Dielectrics such as Benzocyclobutane and Spin-on Glass

Developers
Photoresist Removers