Lithography Recipes: Difference between revisions

From UCSB Nanofab Wiki
Jump to navigation Jump to search
Content deleted Content added
→Lift-Off Techniques: changed to Liftoff Recipes
rearrange manual TOC
Line 7: Line 7:
!Table of Contents
!Table of Contents
|-
|-
|'''<u><big>Photolithography Processes</big></u>'''
|
*'''[[#PositivePR |Photoresists]]'''
*'''[[#PositivePR |Photoresists]]'''
**[[#Photolithography_Recipes |Photo Lithography Recipe section]]
**[[#Photolithography_Recipes |Photo Lithography Recipe section]]
Line 14: Line 14:
**[[#PositivePR |Stocked Lithography Chemical + Datasheets]]
**[[#PositivePR |Stocked Lithography Chemical + Datasheets]]
***''Lists all stocked photolith. chemicals, PRs, strippers, developers, and links to the chemical's application notes/datasheet, which detail the spin curves and nominal processes.''
***''Lists all stocked photolith. chemicals, PRs, strippers, developers, and links to the chemical's application notes/datasheet, which detail the spin curves and nominal processes.''
*'''[[#EBLPR |E-beam Lithography Resists]]'''
*'''[[Lithography Recipes#Lift-Off Recipes|Lift-Off Recipes]]'''
⚫
**''Verified Recipes for lift-off using various photolith. tools''
⚫
**''General educational description of this technique and it's limitations/considerations.''
*'''E-beam Lithography'''
**[[#E-Beam_Lithography_Recipes |E-Beam Lithography Recipes]]
**[[#E-Beam_Lithography_Recipes |E-Beam Lithography Recipes]]
***''Has links to starting recipes. Substrates and patterns play a large role in process parameters.''
***''Has links to starting recipes. Substrates and patterns play a large role in process parameters.''
**[[#EBLPR |EBL Photoresist Datasheets]]
**[[#EBLPR |EBL Photoresist Datasheets]]
***''Provided for reference, also showing starting recipes and usage info.''
***''Provided for reference, also showing starting recipes and usage info.''
⚫
*'''[[Lithography Recipes#Holography Recipes|Holography]]'''
⚫
**''For 1-D and 2-D gratings with 220nm nominal period, available on substrates up to 1 inch square.''
⚫
**''Recipes for silicon substrates are provided, and have been translated to other substrates by users.''
*'''[[#NanoImprinting |Nanoimprinting Resists]]'''
*'''[[#NanoImprinting |Nanoimprinting Resists]]'''
**''Datasheets are provided with starting recipes and usage info.''
**''Datasheets are provided with starting recipes and usage info.''
**''Recipes provided are for use in the [[Nano-Imprint_(Nanonex_NX2000) |Nano-Imprint (Nanonex NX2000)]] system only.''
**''Recipes provided are for use in the [[Nano-Imprint_(Nanonex_NX2000) |Nano-Imprint (Nanonex NX2000)]] system only.''


<u>'''<big>Photolithography Chemicals/Materials</big>'''</u>
*'''[[#Underlayers |Underlayers]]'''
*'''[[#Underlayers |Underlayers]]'''
**''These are used beneath resists for both adhesive purposes and to enable bi-layer lift-off profiles for use with photoresist.''
**''These are used beneath resists for both adhesive purposes and to enable bi-layer lift-off profiles for use with photoresist.''
**''Datasheets are provided.''
**''Datasheets are provided.''
*[[#Lift-Off_Techniques |'''Lift-Off Techniques''']]
⚫
**''Verified Recipes for lift-off using various photolith. tools''
⚫
**''General educational description of this technique and it's limitations/considerations.''
⚫
*'''[[Lithography Recipes#Holography Recipes|Holography]]'''
⚫
**''For 1-D and 2-D gratings with 220nm nominal period, available on substrates up to 1 inch square.''
⚫
**''Recipes for silicon substrates are provided, and have been translated to other substrates by users.''
*'''[[#AntiReflectionCoatings |Anti-Reflection Coatings]]''':
*'''[[#AntiReflectionCoatings |Anti-Reflection Coatings]]''':
**[[#Photolithography_Recipes |The Photoresist Recipes]] section contains recipes using these materials.
**[[#Photolithography_Recipes |The Photoresist Recipes]] section contains recipes using these materials.
Line 281: Line 282:
|}
|}
<!-- end Litho Recipes table -->
<!-- end Litho Recipes table -->

⚫
==Lift-Off Recipes==

⚫
*{{fl|Liftoff-Techniques.pdf|Lift-Off Description/Tutorial}}
⚫
**How it works, process limits and considerations for designing your process
⚫
*{{fl|Bi-LayerContactprocesswithPMGI.pdf|I-Line Lift-Off: Bi-Layer Process with PMGI Underlayer and Contact Aligner}}
⚫
*[[Lift-Off with DUV Imaging + PMGI Underlayer|DUV Lift-Off: UV6 Imaging Resist + PMGI Underlayer]]


==[[E-Beam Lithography System (JEOL JBX-6300FS)|E-Beam Lithography Recipes (JEOL JBX-6300FS)]]==
==[[E-Beam Lithography System (JEOL JBX-6300FS)|E-Beam Lithography Recipes (JEOL JBX-6300FS)]]==
Line 311: Line 319:
*{{fl|BCB-cyclotene-3000-revA.pdf|Standard BCB (3022-46)}}
*{{fl|BCB-cyclotene-3000-revA.pdf|Standard BCB (3022-46)}}
*{{fl|512B-Application-Data-Bake-revA.pdf|SOG (T512B)}}
*{{fl|512B-Application-Data-Bake-revA.pdf|SOG (T512B)}}

⚫
==Lift-Off Recipes==

⚫
*{{fl|Liftoff-Techniques.pdf|Lift-Off Description/Tutorial}}
⚫
**How it works, process limits and considerations for designing your process
⚫
*{{fl|Bi-LayerContactprocesswithPMGI.pdf|I-Line Lift-Off: Bi-Layer Process with PMGI Underlayer and Contact Aligner}}
⚫
*[[Lift-Off with DUV Imaging + PMGI Underlayer|DUV Lift-Off: UV6 Imaging Resist + PMGI Underlayer]]


==Chemicals Stocked + Datasheets==
==Chemicals Stocked + Datasheets==

Revision as of 00:41, 19 September 2020

General Information

This page contains information and links to recipes/datasheets spin-coated materials used in the facility.

Table of Contents
Photolithography Processes
  • Photoresists
    • Photo Lithography Recipe section
      • Has links to starting recipes (spin, bake, exposure, develop etc.).
      • Substrate, surface materials, pattern size can often affect process parameters. Users may need to run Focus/Exposure Arrays/Matrix (FEA's/FEM's) with these processes to achieve high-resolution.
    • Stocked Lithography Chemical + Datasheets
      • Lists all stocked photolith. chemicals, PRs, strippers, developers, and links to the chemical's application notes/datasheet, which detail the spin curves and nominal processes.
  • Lift-Off Recipes
    • Verified Recipes for lift-off using various photolith. tools
    • General educational description of this technique and it's limitations/considerations.
  • E-beam Lithography
  • Holography
    • For 1-D and 2-D gratings with 220nm nominal period, available on substrates up to 1 inch square.
    • Recipes for silicon substrates are provided, and have been translated to other substrates by users.
  • Nanoimprinting Resists

Photolithography Chemicals/Materials

  • Underlayers
    • These are used beneath resists for both adhesive purposes and to enable bi-layer lift-off profiles for use with photoresist.
    • Datasheets are provided.
  • Anti-Reflection Coatings:
    • The Photoresist Recipes section contains recipes using these materials.
    • Bottom Anti-Reflection Coatings (BARC) are used in the stepper systems, underneath the resists to eliminate substrate reflections that can affect resolution and repeatability for small, near resolution limited, feature sizes.
    • Datasheets are provided for reference on use of the materials.
  • Contrast Enhancement Materials (CEM)
    • The Photoresist Recipes section contains recipes using these materials.
    • Used for resolution enhancement. Not for use in contact aligners, typically used on I-Line Steppers.
    • Datasheets provided with usage info.
  • Adhesion Promoters
    • These are used to improve wetting of photoresists to your substrate.
    • Datasheets are provided on use of these materials.

Photolithography Recipes

  • R = Recipe is available. Clicking this link will take you to the recipe.
  • A = Material is available for use, but no recipes are provided.


Photolithography Recipes
Contact Aligner Recipes Stepper Recipes Other
Positive Resists SUSS MJB-3 SUSS MA-6 Stepper 1
(GCA 6300)
Stepper 2
(AutoStep 200)
Stepper 3
(ASML DUV)
MLA150
(Heidelberg)
AZ4110 R1 R1 A A
AZ4210 R1 R1 A A
AZ4330RS R1 R1 A A
AZ4620 A
OCG 825-35CS A A A A
SPR 950-0.8 A A A A
SPR 955 CM-0.9 A R1 R1 R1
SPR 955 CM-1.8 A A R1 R1
SPR 220-3.0 R1 R1 R1 R1
SPR 220-7.0 R1 R1 R1 R1
THMR-IP3600 HP D A A A
UV6-0.8 R1
UV210-0.3 R1
UV26-2.5 A
Negative Resists SUSS MJB-3 SUSS MA-6 Stepper 1
(GCA 6300)
Stepper 2
(AutoStep 200)
Stepper 3
(ASML DUV)
MLA150
(Heidelberg)
AZ5214-EIR R1 R1 R1 R1
AZnLOF 2020 R1 R1 R1 R1
AZnLOF 2035 A A A A
AZnLOF 2070 A A A A
AZnLOF 5510 A A R1 R1
UVN30-0.8 R1
SU-8 2005,2010, 2015 A R1 A A
SU-8 2075 A A A A
NR9-1000,3000,6000PY R1 R1 A R1
Anti-Reflection Coatings SUSS MJB-3 SUSS MA-6 Stepper 1
(GCA 6300)
Stepper 2
(AutoStep 200)
Stepper 3
(ASML DUV)
MLA150
(Heidelberg)
DUV42-P R1
DS-K101-304 R1
SUSS MJB-3 SUSS MA-6 Stepper 1
(GCA 6300)
Stepper 2
(AutoStep 200)
Stepper 3
(ASML DUV)
MLA150
(Heidelberg)

Lift-Off Recipes

E-Beam Lithography Recipes (JEOL JBX-6300FS)

  • Under Development.

FIB Lithography Recipes (Raith Velion)

To Be Added

Automated Coat/Develop System Recipes (S-Cubed Flexi)

Recipes pre-loaded on the S-Cubed Flexi automated coat/bake/develop system. Only staff may write new recipes, contact the tool supervisor for more info.

To Be Added

Nanoimprinting Recipes

Holography Recipes

Low-K Spin-On Dielectric Recipes

Chemicals Stocked + Datasheets

The following is a list of the lithography chemicals we stock in the lab, with links to the datasheets for each. The datasheets will often have important processing info such as spin-speed vs. thickness curves, typical process parameters, bake temps/times etc.

Positive Photoresists

i-line and broadband

DUV-248nm

Negative Photoresists

i-line and broadband

DUV-248nm

Underlayers
E-beam resists
Nanoimprinting
Contrast Enhancement Materials
Anti-Reflection Coatings
Adhesion Promoters
Spin-On Dielectrics

Low-K Spin-On Dielectrics such as Benzocyclobutane and Spin-on Glass

Developers
Photoresist Removers