Recent changes

Jump to navigation Jump to search

Track the most recent changes to the wiki on this page.

Recent changes options Show last 50 | 100 | 250 | 500 changes in last 1 | 3 | 7 | 14 | 30 days
Hide registered users | Hide anonymous users | Show my edits | Show bots | Hide minor edits
Show new changes starting from 10:56, 5 October 2024
   
List of abbreviations:
N
This edit created a new page (also see list of new pages)
m
This is a minor edit
b
This edit was performed by a bot
(±123)
The page size changed by this number of bytes

4 October 2024

 m   16:04  Stepper 2 (AutoStep 200) diffhist +3 John d talk contribs →‎Reference/Other Info Tag: Visual edit
     15:31  Dry Etching Recipes diffhist 0 Noahdutra talk contribs changed Oxford GaAs to R2 since we have no data, but there is a recipe on the tool. Tag: Visual edit

3 October 2024

     18:36  Template:Announcements diffhist +330 Mehalana v talk contribs
     10:59  Surface Analysis (KLA/Tencor Surfscan)‎‎ 10 changes history -1 [Biljana‎ (10×)]
     
10:59 (cur | prev) -90 Biljana talk contribs →‎Operating Procedures
     
10:58 (cur | prev) +90 Biljana talk contribs →‎Operating Procedures
     
10:53 (cur | prev) -107 Biljana talk contribs →‎Operating Procedures
     
10:53 (cur | prev) +104 Biljana talk contribs →‎Operating Procedures
     
10:51 (cur | prev) -91 Biljana talk contribs →‎Operating Procedures
     
10:50 (cur | prev) -1 Biljana talk contribs →‎Operating Procedures
     
10:49 (cur | prev) +3 Biljana talk contribs →‎Operating Procedures
     
10:45 (cur | prev) -4 Biljana talk contribs →‎Operating Procedures
     
10:36 (cur | prev) +4 Biljana talk contribs →‎Operating Procedures
     
10:34 (cur | prev) +91 Biljana talk contribs →‎Operating Procedures

2 October 2024

     22:19  Mask Making Guidelines for Contact Aligners diffhist +146 John d talk contribs →‎Generic Contact Mask Parameters: added CAD images Tag: Visual edit: Switched
 m   22:15  Calculators + Utilities diffhist -1 John d talk contribs →‎CAD Files & Templates: indent figure
     22:03  Stepper 1 (GCA 6300) diffhist +248 John d talk contribs added related tools Tag: Visual edit
     22:02  Stepper 2 (AutoStep 200) diffhist +189 John d talk contribs added Related Tools Tag: Visual edit
     17:52  Template:News‎‎ 2 changes history +22 [John d‎ (2×)]
     
17:52 (cur | prev) -2 John d talk contribs →‎NSF-ATE Award for SBCC and UCSB: AS Degree in Semiconductors
     
17:51 (cur | prev) +24 John d talk contribs →‎NSF-ATE Award for SBCC and UCSB: AS Degree in Semiconductors: change associates degree language according to Jens's request
     17:46  Template:Announcements diffhist -924 John d talk contribs updated MLA, deleted DSE and YES
     17:44  Nanofab Job Postings diffhist +162 John d talk contribs updated hiring dates to Spring 2025, added expansion into other cals. Tag: Visual edit
     10:32  Fluorine ICP Etcher (PlasmaTherm/SLR Fluorine ICP) diffhist +223 Noahdutra talk contribs →‎Process Control Data: added picture to this page for Si etch Tag: Visual edit

1 October 2024

     00:22  Demis D. John diffhist +301 John d talk contribs →‎Tools: added backup section and tools. Tag: Visual edit

30 September 2024

     14:24  PECVD Recipes‎‎ 2 changes history +42 [Biljana‎ (2×)]
     
14:24 (cur | prev) +4 Biljana talk contribs →‎Gap-Fill SiO2 [ICP-PECVD]
     
13:53 (cur | prev) +38 Biljana talk contribs →‎Gap-Fill SiO2 [ICP-PECVD]
     09:36  ICP Etching Recipes diffhist +157 Noahdutra talk contribs Added a photo attributed to the SiVertHFv2 cal recipe Tag: Visual edit
     09:23  (Upload log) [Noahdutra‎ (2×)]
     
09:23 Noahdutra talk contribs uploaded File:PRStrip 019 (1).jpg(Si Etch FICP 9/19/24)
     
09:15 Noahdutra talk contribs uploaded File:PRStrip 022 (1).jpg

27 September 2024

     14:56 Upload log John d talk contribs uploaded a new version of File:Nanofabrication Facility Project Description.xlsx(Rev v2024-09-27 - unlocked PI Phone number.)
     12:20  Template:Announcements diffhist +351 Mehalana v talk contribs
     12:07  Surface Analysis (KLA/Tencor Surfscan)‎‎ 20 changes history +116 [Biljana‎ (20×)]
     
12:07 (cur | prev) +2 Biljana talk contribs →‎Operating Procedures
     
12:07 (cur | prev) -3 Biljana talk contribs →‎Operating Procedures
     
12:06 (cur | prev) -29 Biljana talk contribs →‎Operating Procedures
     
12:06 (cur | prev) 0 Biljana talk contribs →‎Operating Procedures
     
12:05 (cur | prev) 0 Biljana talk contribs →‎Operating Procedures
     
12:05 (cur | prev) +70 Biljana talk contribs →‎Operating Procedures
     
12:04 (cur | prev) +150 Biljana talk contribs →‎Operating Procedures
     
11:46 (cur | prev) 0 Biljana talk contribs →‎Operating Procedures
     
11:45 (cur | prev) +28 Biljana talk contribs →‎Operating Procedures
     
11:43 (cur | prev) -150 Biljana talk contribs →‎Operating Procedures
     
11:43 (cur | prev) 0 Biljana talk contribs →‎Operating Procedures
     
11:43 (cur | prev) -13 Biljana talk contribs →‎Operating Procedures
     
11:42 (cur | prev) +1 Biljana talk contribs →‎Operating Procedures
     
11:41 (cur | prev) -2 Biljana talk contribs →‎Operating Procedures
     
11:41 (cur | prev) -103 Biljana talk contribs →‎Operating Procedures
     
11:39 (cur | prev) +74 Biljana talk contribs →‎Operating Procedures
     
11:38 (cur | prev) +5 Biljana talk contribs →‎Operating Procedures
     
11:38 (cur | prev) -49 Biljana talk contribs →‎Operating Procedures
     
11:37 (cur | prev) +146 Biljana talk contribs →‎Operating Procedures
     
11:34 (cur | prev) -11 Biljana talk contribs →‎Operating Procedures