Recent changes

Jump to navigation Jump to search

Track the most recent changes to the wiki on this page.

Recent changes options Show last 50 | 100 | 250 | 500 changes in last 1 | 3 | 7 | 14 | 30 days
Hide registered users | Hide anonymous users | Show my edits | Show bots | Hide minor edits
Show new changes starting from 18:25, 10 November 2024
   
List of abbreviations:
N
This edit created a new page (also see list of new pages)
m
This is a minor edit
b
This edit was performed by a bot
(±123)
The page size changed by this number of bytes

8 November 2024

     19:10  Wet Etching Recipes diffhist +149 Biljana talk contribs (→‎Table of Wet Etching Recipes: BHF:DI =1:100 etch rate for ALD -SiO2 BDEAS film) Tag: Visual edit

7 November 2024

     21:57  Vacuum Deposition Recipes‎‎ 2 changes history −2,346 [Noahdutra‎ (2×)]
     
21:57 (cur | prev) +94 Noahdutra talk contribs (Added AuSn to Thermal evap 2) Tag: Visual edit
     
21:49 (cur | prev) −2,440 Noahdutra talk contribs (changing thermal evaps to be correct) Tag: Visual edit
     21:38  Services diffhist −2 John d talk contribs (→‎Statement of Work: moved filename to top) Tag: Visual edit
     18:04  Process Group - Process Control Data diffhist +416 John d talk contribs (added GaN etch cal →‎Oxford PlasmaPro Cobra Etcher)
     02:00  Oxford ICP Etcher (PlasmaPro 100 Cobra)‎‎ 2 changes history +1,453 [John d‎ (2×)]
 m   
02:00 (cur | prev) +226 John d talk contribs (→‎Process Control Data) Tag: Visual edit: Switched
     
02:00 (cur | prev) +1,227 John d talk contribs (link to PC data) Tag: Visual edit: Switched
     00:45  Template:Announcements diffhist −704 John d talk contribs (deleted ASML update)

6 November 2024

     21:51  DSEIII (PlasmaTherm/Deep Silicon Etcher) diffhist +1,325 John d talk contribs (pasted NoahD's example SEM's) Tag: Visual edit: Switched
     21:47  Process Group - Process Control Data‎‎ 3 changes history +1,603 [John d‎ (3×)]
     
21:47 (cur | prev) +1,010 John d talk contribs (→‎Etching (Process Control Data): pasted process control data link/image from DSE recipes page) Tag: Visual edit
 m   
21:42 (cur | prev) +242 John d talk contribs (→‎PlasmaTherm SLR Fluorine Etcher: subscripts in chemicals) Tag: Visual edit
     
21:38 (cur | prev) +351 John d talk contribs (describe purpose of 2 diff EtchCals) Tag: Visual edit
     21:43  Atomic Layer Deposition Recipes diffhist +38 Biljana talk contribs (→‎SiO2 deposition (ALD CHAMBER 1): Added (BHF:DI=1:100) etch rate) Tag: Visual edit
     21:39  Fluorine ICP Etcher (PlasmaTherm/SLR Fluorine ICP)‎‎ 4 changes history +50 [John d‎ (4×)]
 m   
21:39 (cur | prev) +44 John d talk contribs (→‎Process Control Data) Tag: Visual edit
 m   
21:39 (cur | prev) +11 John d talk contribs (→‎Process Control Data) Tag: Visual edit
     
21:39 (cur | prev) −35 John d talk contribs (→‎Process Control Data: pasted PC images+links, cleaned up) Tag: Visual edit
     
21:30 (cur | prev) +30 John d talk contribs (→‎Process Control Data: pasted PC images/links from PC page)
     21:26 Upload log John d talk contribs uploaded a new version of File:ICP2 Process Control Data Example.jpg(newer data, "example" label)
     21:22  ICP Etch 2 (Panasonic E626I) diffhist +366 John d talk contribs (→‎Recipes: added Process Control Header level 1 & images from PC page) Tag: Visual edit: Switched
 m   21:14  Process Group Interns diffhist −5 John d talk contribs Tag: Visual edit
N    21:12  Process Group Internships‎‎ 3 changes history +5,528 [John d‎ (3×)]
 m   
21:12 (cur | prev) +71 John d talk contribs Tag: Visual edit
     
21:09 (cur | prev) +7 John d talk contribs (Intenrhsip Goals heading) Tag: Visual edit
N    
21:00 (cur | prev) +5,450 John d talk contribs (internship goals, skillss learns and detailed 2-phase approach) Tag: Visual edit
     16:54  Lithography Recipes diffhist +444 John d talk contribs (→‎General Photolithography Techniques: link to FEM page) Tag: Visual edit

5 November 2024

     23:54  (Upload log) [John d‎ (2×)]
     
23:54 John d talk contribs uploaded a new version of File:FEM example analysis GMoody Group 2024-11-04 v2.png(added X in middle)
     
23:47 John d talk contribs uploaded File:FEM example analysis GMoody Group 2024-11-04 v2.png
     23:52  Lithography Calibration - Analyzing a Focus-Exposure Matrix diffhist +465 John d talk contribs (uploaded Moody group FEM example) Tag: Visual edit

4 November 2024

     22:51  Services diffhist +25 John d talk contribs (→‎Fabrication Services by NanoFab Staff: clarify charged rates) Tag: Visual edit

2 November 2024

     17:48  SEM 1 (JEOL IT800SHL)‎‎ 2 changes history +210 [John d‎ (2×)]
 m   
17:48 (cur | prev) +15 John d talk contribs (→‎Operating Procedures) Tag: Visual edit
     
16:41 (cur | prev) +195 John d talk contribs (→‎Operating Procedures: link to reduced cahrging imaging modes page) Tag: Visual edit
     17:38  Hummer SEM Sample Coater - Techniques to reduce charging in SEMs diffhist +46 John d talk contribs Tag: Visual edit
N    17:35  JEOL IT800SHL - Reduced Charging Imaging Modes‎‎ 2 changes history +2,972 [John d‎ (2×)]
     
17:35 (cur | prev) +353 John d talk contribs (AUPd help) Tag: Visual edit
N    
17:30 (cur | prev) +2,619 John d talk contribs (reduced charging by Demis,f rom JEOL training by Jen 2024-09) Tag: Visual edit

31 October 2024

     16:32  E-Beam 2 (Custom) diffhist 0 Sawyer l talk contribs (SOP rev) Tag: Visual edit
     16:31 Upload log Sawyer l talk contribs uploaded File:EB2 SOP Rev I.pdf

30 October 2024

     23:58  Vacuum Deposition Recipes diffhist −55 Noahdutra talk contribs Tag: Visual edit

28 October 2024

     21:38  Probe Station: I-V Curves with Keithley 2400 and Python Script diffhist +67 John d talk contribs (added computer login) Tag: Visual edit

27 October 2024

     17:28  MLA150 - Troubleshooting diffhist +293 John d talk contribs (→‎Analyzing misalignment: further explain how to draw arrows) Tag: Visual edit

26 October 2024

     19:39  Maskless Aligner (Heidelberg MLA150)‎‎ 3 changes history +235 [John d‎ (3×)]
 m   
19:39 (cur | prev) −16 John d talk contribs (→‎Recipes) Tag: Visual edit
     
19:36 (cur | prev) +112 John d talk contribs (→‎Documentation: link to new MLA150 FEM page) Tag: Visual edit
     
19:35 (cur | prev) +139 John d talk contribs (→‎Recipes: link to FEM analysis section, mention "Series" for FEM) Tag: Visual edit
N    19:38  MLA150 - Focus-Exposure Matrix ("Series" mode) diffhist +21 John d talk contribs (to be added) Tag: Visual edit
     19:32  Stepper 1 (GCA 6300) diffhist +723 John d talk contribs (added Recipes section with link to recipes, FEM analysis etc) Tag: Visual edit
     19:30  Stepper 2 (AutoStep 200) diffhist +728 John d talk contribs (link to FEM analysis pages, Stepper 2 recipes page) Tag: Visual edit
     19:26  Stepper 3 (ASML DUV) diffhist +339 John d talk contribs (→‎Recipes: added FEM analysis link) Tag: Visual edit
     19:02  (Upload log) [John d‎ (3×)]
     
19:02 John d talk contribs uploaded File:UCSB NetID - correct google account v1.png
     
18:50 John d talk contribs uploaded File:UCSB NetID wrong google account access denied v1.png
     
18:46 John d talk contribs uploaded File:UCSB NetID - wrong login access denied.png