Recent changes

Jump to navigation Jump to search

Track the most recent changes to the wiki on this page.

Recent changes options Below are the changes since 6 July 2024, 13:52 (up to 50 shown). (Reset date selection)
Show last 50 | 100 | 250 | 500 changes in last 1 | 3 | 7 | 14 | 30 days
Hide registered users | Hide anonymous users | Hide my edits | Show bots | Show minor edits
Show new changes starting from 11:31, 5 August 2024
   
List of abbreviations:
N
This edit created a new page (also see list of new pages)
m
This is a minor edit
b
This edit was performed by a bot
(±123)
The page size changed by this number of bytes

5 August 2024

     10:16  Vacuum Deposition Recipes‎‎ 5 changes history +3,717 [Noahdutra‎ (5×)]
     
10:16 (cur | prev) +2,866 Noahdutra talk contribs added Ebeams rankings Tag: Visual edit
     
09:55 (cur | prev) -30 Noahdutra talk contribs Tag: Visual edit
     
09:54 (cur | prev) -47 Noahdutra talk contribs Tag: Visual edit
     
09:53 (cur | prev) +16 Noahdutra talk contribs Tag: Visual edit
     
09:52 (cur | prev) +912 Noahdutra talk contribs added process ranking table Tag: Visual edit

3 August 2024

N    18:05  Processing - How Do I…? diffhist +538 John d talk contribs initial holders Tag: Visual edit

1 August 2024

     17:21  Hummer SEM Sample Coater - Techniques to reduce charging in SEMs diffhist +272 John d talk contribs link to Hummer tool page Tag: Visual edit
     17:17  SEM Sample Coater (Hummer)‎‎ 2 changes history +38 [John d‎ (2×)]
     
17:17 (cur | prev) +1 John d talk contribs →‎Operating Procedures: fixed bullet points, listed approx film thickness Tag: Visual edit
     
17:17 (cur | prev) +37 John d talk contribs →‎About Tag: Visual edit
     17:16  SEM 1 (JEOL IT800SHL) diffhist +70 John d talk contribs →‎Operating Procedures: link to hummer techniques Tag: Visual edit

31 July 2024

     18:52  Template:Announcements diffhist +372 Mehalana v talk contribs
     17:46  Lift-Off with DUV Imaging + PMGI Underlayer diffhist +148 John d talk contribs →‎Suggested Process for Liftoff: added N2 dry step Tag: Visual edit
     14:13  Vacuum Deposition Recipes‎‎ 6 changes history -522 [Ffoong‎ (6×)]
     
14:13 (cur | prev) -20 Ffoong talk contribs Correct the links for UNAXIS PECVD Tag: Visual edit
     
14:12 (cur | prev) -10 Ffoong talk contribs Tag: Visual edit
     
14:11 (cur | prev) +4 Ffoong talk contribs Add R level for UNAXIS PECVD Tag: Visual edit
     
13:39 (cur | prev) -20 Ffoong talk contribs R5 on IBD Al2O3 Tag: Visual edit
     
13:38 (cur | prev) -504 Ffoong talk contribs Added R levels to IBD dep Tag: Visual edit
     
11:00 (cur | prev) +28 Ffoong talk contribs add R levels for ALD system Tag: Visual edit

30 July 2024

     15:34  Vacuum Deposition Recipes‎‎ 3 changes history +34 [Ffoong‎ (3×)]
     
15:34 (cur | prev) +15 Ffoong talk contribs change PECVD1 R levels and add links Tag: Visual edit
     
15:18 (cur | prev) +18 Ffoong talk contribs Changed PECVD2 levels and added proper internal links Tag: Visual edit
     
15:13 (cur | prev) +1 Ffoong talk contribs Changed Si in PECVD2 to R3 Tag: Visual edit
     15:04  Dry Etching Recipes‎‎ 5 changes history +98 [Ffoong‎; Noahdutra‎ (4×)]
     
15:04 (cur | prev) -1 Noahdutra talk contribs changed "Process Control Data" link at the top so it didn't have an "f" at the front of it. Tag: Visual edit
     
14:33 (cur | prev) 0 Ffoong talk contribs changed Al2O3 etch from R4 to R3 Tag: Visual edit
     
10:39 (cur | prev) +85 Noahdutra talk contribs corrected SiC for ICP2 so that it is R1 instead of R4, which was a mistake to ever put it at R4. Also added a link to GaAs etch on ICP2 Tag: Visual edit
     
10:36 (cur | prev) +83 Noahdutra talk contribs added link to Al etch Tag: Visual edit
     
10:35 (cur | prev) -69 Noahdutra talk contribs Did process rankings for ICP2, I also deleted a redundant row for Ru, there were two Ru rows Tag: Visual edit
     09:02  Laser Scanning Confocal M-scope (Olympus LEXT) diffhist +6 Hopkins a talk contribs →‎Offline software Tag: Visual edit
     09:00 Upload log Hopkins a talk contribs uploaded File:LEXT OLS4100 InstallManual Ver.3.1.8 offline.pdf(LEXT Offline software)
     08:10  Suss Aligners (SUSS MJB-3) diffhist +2 Sawyer l talk contribs
     08:10  Contact Aligner (SUSS MA-6) diffhist +2 Sawyer l talk contribs
     08:09  E-Beam 2 (Custom) diffhist +1 Sawyer l talk contribs
     08:06  ICP Etch 2 (Panasonic E626I) diffhist -6 Sawyer l talk contribs Tag: Visual edit: Switched

29 July 2024

     19:24  SEM 1 (JEOL IT800SHL) diffhist +108 John d talk contribs →‎Imaging: added minor descriptions on detector types Tag: Visual edit

26 July 2024

     16:26  Template:Announcements diffhist +20 Mehalana v talk contribs →‎Unaxis ICP-PECVD Update
     14:34  Dry Etching Recipes‎‎ 4 changes history +6 [Ffoong‎ (4×)]
     
14:34 (cur | prev) +5 Ffoong talk contribs Update OXFD recipe maturity levels Tag: Visual edit
     
14:24 (cur | prev) +1 Ffoong talk contribs input OXFD recipe maturity levels Tag: Visual edit
     
14:15 (cur | prev) +350 Ffoong talk contribs Undo revision 162126 by Ffoong (talk) Tag: Undo
     
14:05 (cur | prev) -350 Ffoong talk contribs update R levels to show maturity as defined in CA-Dreams Tag: Visual edit
     10:12  Laser Etch Monitoring‎‎ 2 changes history +910 [John d‎ (2×)]
     
10:12 (cur | prev) +121 John d talk contribs →‎Substrate Temperature Stabilization Tag: Visual edit
     
10:08 (cur | prev) +789 John d talk contribs added Joel's DSP Substrate trace example Tag: Visual edit
     10:06 Upload log John d talk contribs uploaded File:LaserMon - Temp Stabilize JoelGuo - 240725 noGas hold200C InPepi DSP.png

25 July 2024

     10:49  Template:Announcements‎‎ 3 changes history -107 [Mehalana v‎ (3×)]
     
10:49 (cur | prev) +1 Mehalana v talk contribs →‎Wafer Bonder, (Suss SB6-8E)
     
10:48 (cur | prev) +34 Mehalana v talk contribs →‎Unaxis ICP-PECVD Update
     
10:48 (cur | prev) -142 Mehalana v talk contribs

24 July 2024

     09:47  Dry Etching Recipes‎‎ 3 changes history +228 [John d‎ (3×)]
     
09:47 (cur | prev) +1 John d talk contribs fixed Pan1/2 links Tag: Visual edit
     
09:32 (cur | prev) +95 John d talk contribs →‎Process Ranking Table: minor updates to Process Maturity level Tag: Visual edit
     
09:30 (cur | prev) +132 John d talk contribs mention + link to table Key/Legend Tag: Visual edit

19 July 2024

     15:47  Dry Etching Recipes‎‎ 3 changes history -2 [Noahdutra‎ (3×)]
     
15:47 (cur | prev) -16 Noahdutra talk contribs ficp etch ranking data pt5 Tag: Visual edit
     
15:46 (cur | prev) +16 Noahdutra talk contribs ficp etch ranking data pt4 Tag: Visual edit
     
15:45 (cur | prev) -2 Noahdutra talk contribs ficp etch ranking data pt3 Tag: Visual edit