Tool List: Difference between revisions
Jump to navigation
Jump to search
Content deleted Content added
→Wet Processing: link to Mechanical_Polisher_(Allied) |
→ICP-RIE: link to Oxford ICP new page |
||
| Line 24: | Line 24: | ||
*[[Maskless Aligner (Heidelberg MLA150)]] |
*[[Maskless Aligner (Heidelberg MLA150)]] |
||
===== |
=====Other Patterning Systems===== |
||
*[[Holographic Lith/PL Setup (Custom)|Holographic Litho/PL Setup (Custom)]] |
*[[Holographic Lith/PL Setup (Custom)|Holographic Litho/PL Setup (Custom)]] |
||
| width="400" | |
| width="400" | |
||
| Line 111: | Line 112: | ||
*[[ICP Etch 2 (Panasonic E640)]] |
*[[ICP Etch 2 (Panasonic E640)]] |
||
*[[ICP-Etch (Unaxis VLR)]] |
*[[ICP-Etch (Unaxis VLR)]] |
||
*[[Oxford ICP Etcher (PlasmaPro 100 Cobra)]] |
|||
*[[Fluorine ICP Etcher (PlasmaTherm/SLR Fluorine ICP)|Plasma-Therm SLR: Fluorine ICP (PlasmaTherm/SLR Fluorine Etcher)]] |
*[[Fluorine ICP Etcher (PlasmaTherm/SLR Fluorine ICP)|Plasma-Therm SLR: Fluorine ICP (PlasmaTherm/SLR Fluorine Etcher)]] |
||
*[[DSEIII (PlasmaTherm/Deep Silicon Etcher)|Plasma-Therm DSE-iii (PlasmaTherm/Deep Silicon Etcher)]] |
*[[DSEIII (PlasmaTherm/Deep Silicon Etcher)|Plasma-Therm DSE-iii (PlasmaTherm/Deep Silicon Etcher)]] |
||
| Line 191: | Line 193: | ||
*[[Digital Microscope (Olympus DSX1000)|Digital Microscope #7 (Olympus DSX1000)]] |
*[[Digital Microscope (Olympus DSX1000)|Digital Microscope #7 (Olympus DSX1000)]] |
||
===== |
=====Electron Microscopy===== |
||
*[[Field Emission SEM 1 (FEI Sirion)]] |
*[[Field Emission SEM 1 (FEI Sirion)]] |
||
*[[Field Emission SEM 2 (JEOL 7600F)]] |
*[[Field Emission SEM 2 (JEOL 7600F)]] |
||
| Line 207: | Line 210: | ||
=====Thin-Film/Material Analysis===== |
=====Thin-Film/Material Analysis===== |
||
====== |
======Thickness + Optical Constants====== |
||
*[[Ellipsometer (Woollam)]] |
*[[Ellipsometer (Woollam)]] |
||
*[[Optical Film Thickness (Filmetrics)|Optical Film Thickness (Filmetrics F20)]] |
*[[Optical Film Thickness (Filmetrics)|Optical Film Thickness (Filmetrics F20)]] |
||
| Line 215: | Line 219: | ||
*[[Optical Film Spectra + Optical Properties (Filmetrics F10-RT-UVX)|Reflection/Transmission Spectra & Optical Film Thickness (Filmetrics F10-RT-UVX)]] |
*[[Optical Film Spectra + Optical Properties (Filmetrics F10-RT-UVX)|Reflection/Transmission Spectra & Optical Film Thickness (Filmetrics F10-RT-UVX)]] |
||
====== |
======Other Properties====== |
||
*[[Film Stress (Tencor Flexus)]] |
*[[Film Stress (Tencor Flexus)]] |
||
*[[Photoluminescence PL Setup (Custom)]] |
*[[Photoluminescence PL Setup (Custom)]] |
||
====== |
======Electrical Analysis====== |
||
*[[Resistivity Mapper (CDE RESMAP)]] |
*[[Resistivity Mapper (CDE RESMAP)]] |
||
*[[Probe Station & Curve Tracer]] |
*[[Probe Station & Curve Tracer]] |
||
Revision as of 20:13, 3 September 2021
Lithography
Photoresists and Lithography ChemicalsContact Aligners (Optical Exposure)Direct-Write Lithography
Other Patterning Systems |
Steppers (Optical Exposure)Thermal Processing for Photolithography
Lithography Support
|
Vacuum Deposition
Physical Vapor Deposition (PVD)
Sputter Deposition |
Chemical Vapor Deposition (CVD) |
Dry Etch
Reactive Ion Etching (RIE)Plasma Etching and Cleaning
Etch Monitoring
|
ICP-RIE
Ion Milling and Reactive Ion Beam EtchingOther Dry Etching |
Wet Processing
See the Chemical List page for stocked chemicals such as Developers, Etchants, Solvents etc.
Thermal Processing
Packaging
Inspection, Test and Characterization
Optical Microscopy
Electron MicroscopyTopographical Metrology |
Thin-Film/Material AnalysisThickness + Optical Constants
Other PropertiesElectrical AnalysisOther Tools
|