Tool List: Difference between revisions
Jump to navigation
Jump to search
(Text replacement - "/wiki/index.php/" to "/wiki/index.php?title=") |
(→Electron Microscopy: renamed and fixed link for SEM2) |
||
(24 intermediate revisions by 6 users not shown) | |||
Line 7: | Line 7: | ||
=====Photoresists and Lithography Chemicals===== |
=====Photoresists and Lithography Chemicals===== |
||
*See the [https://wiki.nanotech.ucsb.edu/ |
*See the [https://wiki.nanotech.ucsb.edu/w/index.php?title=Lithography_Recipes#Chemicals_Stocked_.2B_Datasheets Chemical Datasheets page]. |
||
*[[Automated Coat/Develop System (S-Cubed Flexi)|Auto. Coat/Develop (S-Cubed Flexi)]] |
*[[Automated Coat/Develop System (S-Cubed Flexi)|Auto. Coat/Develop (S-Cubed Flexi)]] |
||
=====Contact Aligners (Optical Exposure)===== |
=====Contact Aligners (Optical Exposure)===== |
||
*[[Suss Aligners (SUSS MJB-3)]] |
*[[Suss Aligners (SUSS MJB-3)|Contact Aligners (SUSS MJB-3)]] |
||
⚫ | |||
*[[Contact Aligner (SUSS MA-6)]] |
*[[Contact Aligner (SUSS MA-6)]] |
||
*[[DUV Flood Expose]] |
*[[DUV Flood Expose]] |
||
Line 41: | Line 40: | ||
*[[Oven 5 (Labline)]] |
*[[Oven 5 (Labline)]] |
||
*[[High Temp Oven (Blue M)]] |
*[[High Temp Oven (Blue M)]] |
||
*[[Vacuum Oven (YES)]] |
|||
=====Lithography Support===== |
=====Lithography Support===== |
||
*The [https://wiki.nanotech.ucsb.edu/ |
*The [https://wiki.nanotech.ucsb.edu/w/index.php?title=Wet_Benches#Spin_Coat_Benches Spinner Benches] have pre-set hotplates at various temperatures appropriate for common photoresist bakes. |
||
*[https://signupmonkey.ece.ucsb.edu/ |
*[https://signupmonkey.ece.ucsb.edu/w/index.php?title=Wet_Benches#Automated_Wet-processing_Spinners_.28POLOS.29 POLOS spinners] on Develop and Solvent benches |
||
*[[Spin Rinse Dryer (SemiTool)|Spin/Rinse/Dryer]] |
*[[Spin Rinse Dryer (SemiTool)|Spin/Rinse/Dryer]] |
||
|- |
|- |
||
Line 56: | Line 54: | ||
|- valign="top" |
|- valign="top" |
||
| width="300" | |
| width="300" | |
||
====Physical Vapor Deposition (PVD)==== |
|||
=====Thermal Evaporation===== |
|||
*[[E-Beam 1 (Sharon)]] |
*[[E-Beam 1 (Sharon)]] |
||
Line 62: | Line 62: | ||
*[[E-Beam 3 (Temescal)]] |
*[[E-Beam 3 (Temescal)]] |
||
*[[E-Beam 4 (CHA)]] |
*[[E-Beam 4 (CHA)]] |
||
*[[E-Beam 5 (Plasys)]] |
|||
*[[Thermal Evap 1]] |
*[[Thermal Evap 1]] |
||
*[[Thermal Evap 2 (Solder)]] |
*[[Thermal Evap 2 (Solder)]] |
||
Line 71: | Line 72: | ||
*[[Sputter 5 (AJA ATC 2200-V)]] |
*[[Sputter 5 (AJA ATC 2200-V)]] |
||
*[[Ion Beam Deposition (Veeco NEXUS)]] |
*[[Ion Beam Deposition (Veeco NEXUS)]] |
||
*[[SEM Sample Coater (Hummer)]] |
|||
| width="400" | |
| width="400" | |
||
Line 96: | Line 98: | ||
=====Plasma Etching and Cleaning===== |
=====Plasma Etching and Cleaning===== |
||
*[[Plasma Clean (Gasonics 2000)]] |
|||
*[[Plasma Clean (YES EcoClean)]] |
*[[Plasma Clean (YES EcoClean)]] |
||
*[[Plasma Activation (EVG 810)]] |
*[[Plasma Activation (EVG 810)]] |
||
Line 119: | Line 120: | ||
*[[CAIBE (Oxford Ion Mill)]] |
*[[CAIBE (Oxford Ion Mill)]] |
||
*[[Focused Ion-Beam Lithography (Raith Velion)]] |
|||
=====Other Dry Etching===== |
=====Other Dry Etching===== |
||
Line 138: | Line 140: | ||
**[[Develop Benches]] |
**[[Develop Benches]] |
||
**[[Toxic Corrosive Benches]] |
**[[Toxic Corrosive Benches]] |
||
**[[Wet Benches#Wafer Toxic Corrosive Benches|Wafer Toxic Corrosive Bench]] |
|||
**[[HF/TMAH Processing Benches]] |
**[[HF/TMAH Processing Benches]] |
||
**[[Plating Bench]] |
**[[Plating Bench]] |
||
Line 147: | Line 150: | ||
*[[Mechanical Polisher (Allied)]] |
*[[Mechanical Polisher (Allied)]] |
||
*[[Automated Coat/Develop System (S-Cubed Flexi)|Auto. Coat/Develop (S-Cubed Flexi)]] |
*[[Automated Coat/Develop System (S-Cubed Flexi)|Auto. Coat/Develop (S-Cubed Flexi)]] |
||
*[https://signupmonkey.ece.ucsb.edu/ |
*[https://signupmonkey.ece.ucsb.edu/w/index.php?title=Wet_Benches#Automated_Wet-processing_Spinners_.28POLOS.29 Auto. Wet-Processing Spinners (POLOS)] |
||
|- |
|- |
||
|} |
|} |
||
Line 167: | Line 170: | ||
**[[Oven 4 (Thermo-Fisher HeraTherm)]] |
**[[Oven 4 (Thermo-Fisher HeraTherm)]] |
||
**[[Oven 5 (Labline)]] |
**[[Oven 5 (Labline)]] |
||
**[[Vacuum Oven (YES)]] |
|||
**[[High Temp Oven (Blue M)]] |
**[[High Temp Oven (Blue M)]] |
||
⚫ | |||
|- |
|- |
||
|} |
|} |
||
=Packaging= |
=Packaging= |
||
{| |
|||
⚫ | |||
====Die Singulation / Down-sizing==== |
|||
*[[Dicing Saw (ADT)]] |
*[[Dicing Saw (ADT)]] |
||
*[[Wafer Cleaver (PELCO Flip-Scribe)|Manual Wafer Cleaver (PELCO Flipscribe)]] |
|||
⚫ | |||
*[[Automated Wafer Cleaver (Loomis LSD-155LT)]] |
|||
⚫ | |||
*[[Vacuum Sealer]] |
*[[Vacuum Sealer]] |
||
⚫ | |||
*[[Wire Saw (Takatori)]] |
|||
====Wafer/Die Bonding==== |
|||
⚫ | |||
⚫ | |||
*[[Wafer Bonder (Logitech WBS7)|Wafer Bonder/Wax Mounting (Logitech WBS2)]] |
|||
⚫ | |||
=Inspection, Test and Characterization= |
=Inspection, Test and Characterization= |
||
Line 186: | Line 201: | ||
=====Optical Microscopy===== |
=====Optical Microscopy===== |
||
*[[Microscopes|Optical Microscopes]] |
*[[Microscopes|Optical Microscopes]] - ''General Use'' |
||
*[[Fluorescence Microscope (Olympus MX51)]] |
*[[Fluorescence Microscope (Olympus MX51)]] |
||
*[[Deep UV Optical Microscope (Olympus)]] |
*[[Deep UV Optical Microscope (Olympus)]] |
||
*[[Laser Scanning Confocal M-scope (Olympus LEXT)]] |
*[[Laser Scanning Confocal M-scope (Olympus LEXT)]] |
||
⚫ | |||
*[[Digital Microscope (Olympus DSX1000)|Digital Microscope #7 (Olympus DSX1000)]] |
*[[Digital Microscope (Olympus DSX1000)|Digital Microscope #7 (Olympus DSX1000)]] |
||
=====Electron Microscopy===== |
=====Electron Microscopy===== |
||
*[[ |
*[[SEM 1 (JEOL IT800SHL)]] |
||
*[[Field Emission SEM 2 (JEOL |
*[[Field Emission SEM 2 (JEOL IT800SHL)|SEM 2 (JEOL IT800SHL) w/ EDAX]] |
||
*[[SEM Sample Coater (Hummer)]] |
*[[SEM Sample Coater (Hummer)]] |
||
Line 202: | Line 216: | ||
*[[Step Profilometer (KLA Tencor P-7)]] |
*[[Step Profilometer (KLA Tencor P-7)]] |
||
*[[Step Profilometer ( |
*[[Step Profilometer (DektakXT)]] |
||
*[[Atomic Force Microscope (Bruker ICON)|Atomic Force Microsope (Bruker ICON)]] |
*[[Atomic Force Microscope (Bruker ICON)|Atomic Force Microsope (Bruker ICON)]] |
||
⚫ | |||
**''Sub-micron Particle Counter'' |
|||
*[[Laser Scanning Confocal M-scope (Olympus LEXT)]] |
*[[Laser Scanning Confocal M-scope (Olympus LEXT)]] |
||
| width="400" | |
| width="400" | |
||
=====Thin-Film/Material Analysis===== |
=====Thin-Film/Material Analysis===== |
||
Line 213: | Line 226: | ||
*[[Ellipsometer (Woollam)]] |
*[[Ellipsometer (Woollam)]] |
||
*[[Optical Film Thickness (Filmetrics)|Optical Film Thickness (Filmetrics F20)]] |
|||
*[[Filmetrics F40-UV Microscope-Mounted|Optical Film Thickness (Microscope-Mounted Filmetrics F-40-UV)]] |
*[[Filmetrics F40-UV Microscope-Mounted|Optical Film Thickness (Microscope-Mounted Filmetrics F-40-UV)]] |
||
*[[Optical Film Thickness (Nanometric)]] |
|||
*[[Optical Film Thickness & Wafer-Mapping (Filmetrics F50)]] |
*[[Optical Film Thickness & Wafer-Mapping (Filmetrics F50)]] |
||
*[[Optical Film Spectra + Optical Properties (Filmetrics F10-RT-UVX)|Reflection/Transmission Spectra & Optical Film Thickness (Filmetrics F10-RT-UVX)]] |
*[[Optical Film Spectra + Optical Properties (Filmetrics F10-RT-UVX)|Reflection/Transmission Spectra & Optical Film Thickness (Filmetrics F10-RT-UVX)]] |
||
⚫ | |||
⚫ | |||
⚫ | |||
======Electrical Analysis====== |
======Electrical Analysis====== |
||
*[[Resistivity Mapper (CDE RESMAP)]] |
*[[Resistivity Mapper (CDE RESMAP)]] |
||
*[[Probe Station & Curve Tracer]] |
*[[Probe Station & Curve Tracer|Probe Station & Source/Meter Units]] |
||
⚫ | |||
=====Other |
======Other Properties====== |
||
⚫ | |||
⚫ | |||
⚫ | |||
*[[Goniometer (Rame-Hart A-100)|Goniometer (Ramé-Hart A-100)]] |
*[[Goniometer (Rame-Hart A-100)|Goniometer (Ramé-Hart A-100)]] |
||
**''Surface hydrophobicity'' |
**''Surface hydrophobicity'' |
||
⚫ | |||
⚫ | |||
⚫ | |||
|- |
|- |
||
|} |
|} |
Revision as of 22:33, 12 September 2023
Lithography
Photoresists and Lithography ChemicalsContact Aligners (Optical Exposure)Direct-Write Lithography
Other Patterning Systems |
Steppers (Optical Exposure)Thermal Processing for Photolithography
Lithography Support
|
Vacuum Deposition
Physical Vapor Deposition (PVD)Thermal Evaporation
Sputter Deposition |
Chemical Vapor Deposition (CVD) |
Dry Etch
Reactive Ion Etching (RIE)Plasma Etching and CleaningEtch Monitoring
|
ICP-RIE
Ion Milling and Reactive Ion Beam EtchingOther Dry Etching |
Wet Processing
See the Chemical List page for stocked chemicals such as Developers, Etchants, Solvents etc.
Thermal Processing
Packaging
Die Singulation / Down-sizingOther Packaging |
Wafer/Die Bonding |
Inspection, Test and Characterization
Optical Microscopy
Electron MicroscopyTopographical Metrology |
Thin-Film/Material AnalysisThickness + Optical Constants
Electrical Analysis
Other Properties |