Tool List: Difference between revisions

From UCSB Nanofab Wiki
Jump to navigation Jump to search
m (corrected photo chemicals link, moved inside table for easier location)
 
(64 intermediate revisions by 8 users not shown)
Line 5: Line 5:
|- valign="top"
|- valign="top"
| width="300" |
| width="300" |
===== Photoresists and Lithography Chemicals =====
=====Photoresists and Lithography Chemicals=====
* See the [https://www.nanotech.ucsb.edu/wiki/index.php/Lithography_Recipes#Chemicals_Stocked_.2B_Datasheets Chemical Datasheets page].


*See the [https://wiki.nanotech.ucsb.edu/w/index.php?title=Lithography_Recipes#Chemicals_Stocked_.2B_Datasheets Chemical Datasheets page].
===== Contact Aligners (Optical Exposure) =====
*[[Automated Coat/Develop System (S-Cubed Flexi)|Auto. Coat/Develop (S-Cubed Flexi)]]
* [[Suss Aligners (SUSS MJB-3)]]
* [[IR Aligner (SUSS MJB-3 IR)]]
* [[Contact Aligner (SUSS MA-6)]]
* [[DUV Flood Expose]]


===== Other Patterning Systems =====
=====Contact Aligners (Optical Exposure)=====

* [[E-Beam Lithography System (JEOL JBX-6300FS)]]
*[[Suss Aligners (SUSS MJB-3)|Contact Aligners (SUSS MJB-3)]]
* [[Nano-Imprint (Nanonex NX2000)]]
*[[Contact Aligner (SUSS MA-6)]]
* [[Holographic Lith/PL Setup (Custom)|Holographic Litho/PL Setup (Custom)]]
*[[DUV Flood Expose]]

=====Direct-Write Lithography=====

*[[E-Beam Lithography System (JEOL JBX-6300FS)]]
*[[SEM 1 (JEOL IT800SHL)|E-Beam Lithography (Nabity v9)]]
*[[Focused Ion-Beam Lithography (Raith Velion)]]
*[[Maskless Aligner (Heidelberg MLA150)]]

=====Other Patterning Systems=====

*[[Holographic Lith/PL Setup (Custom)|Holographic Litho/PL Setup (Custom)]]
| width="400" |
| width="400" |
===== Steppers (Optical Exposure) =====
=====Steppers (Optical Exposure)=====

* [[Stepper 1 (GCA 6300)|Stepper 1 (GCA 6300, i-line)]]
* [[Stepper 2 (AutoStep 200)|Stepper 2 (AutoStep 200, i-line)]]
*[[Stepper 1 (GCA 6300)|Stepper 1 (GCA 6300, i-line)]]
* [[Stepper 3 (ASML DUV)|Stepper 3 (ASML DUV, Deep-UV)]]
*[[Stepper 2 (AutoStep 200)|Stepper 2 (AutoStep 200, i-line)]]
*[[Stepper 3 (ASML DUV)|Stepper 3 (ASML DUV, Deep-UV)]]

=====Thermal Processing for Photolithography=====

*[[Ovens - Overview of All Lab Ovens|Ovens - Overview of all lab ovens]]
*[[Ovens 1, 2 & 3 (Labline)]]
*[[Oven 4 (Fisher)]]
*[[Oven 5 (Labline)]]
*[[High Temp Oven (Blue M)]]

=====Lithography Support=====


*The [https://wiki.nanotech.ucsb.edu/w/index.php?title=Wet_Benches#Spin_Coat_Benches Spinner Benches] have pre-set hotplates at various temperatures appropriate for common photoresist bakes.
===== Thermal Processing for Photolithography =====
*[https://signupmonkey.ece.ucsb.edu/w/index.php?title=Wet_Benches#Automated_Wet-processing_Spinners_.28POLOS.29 POLOS spinners] on Develop and Solvent benches
* [[Ovens - Overview of All Lab Ovens|Ovens - Overview of all lab ovens]]
*[[Spin Rinse Dryer (SemiTool)|Spin/Rinse/Dryer]]
* [[Ovens 1, 2 & 3 (Labline)]]
* [[Oven 4 (Fisher)]]
* [[Oven 5 (Labline)]]
* [[High Temp Oven (Blue M)]]
* [[Vacuum Oven (YES)]]
* The [https://www.nanotech.ucsb.edu/wiki/index.php/Wet_Benches#Spin_Coat_Benches Spinner Benches] have pre-set hotplates at various temperatures appropriate for common photoresist bakes.
|-
|-
|}
|}


= Vacuum Deposition =
=Vacuum Deposition=


{|
{|
|- valign="top"
|- valign="top"
| width="300" |
| width="300" |
===== Physical Vapor Deposition (PVD) =====
====Physical Vapor Deposition (PVD)====
*[[E-Beam 1 (Sharon)]]
*[[E-Beam 2 (Custom)]]
*[[E-Beam 3 (Temescal)]]
*[[E-Beam 4 (CHA)]]
*[[Thermal Evap 1]]
*[[Thermal Evap 2 (Solder)]]


===== Sputter Deposition =====
=====Thermal Evaporation=====

*[[Sputter 3 (AJA ATC 2000-F)]]
*[[Sputter 4 (AJA ATC 2200-V)]]
*[[E-Beam 1 (Sharon)]]
*[[E-Beam 2 (Custom)]]
*[[E-Beam 3 (Temescal)]]
*[[E-Beam 4 (CHA)]]
*[[E-Beam 5 (Plasys)]]
*[[Thermal Evap 1]]
*[[Thermal Evap 2 (Solder)]]

=====Sputter Deposition=====

*[[Sputter 3 (AJA ATC 2000-F)]]
*[[Sputter 4 (AJA ATC 2200-V)]]
*[[Sputter 5 (AJA ATC 2200-V)]]
*[[Sputter 5 (AJA ATC 2200-V)]]
*[[Ion Beam Deposition (Veeco NEXUS)]]
*[[Ion Beam Deposition (Veeco NEXUS)]]
*[[SEM Sample Coater (Hummer)]]


| width="400" |
| width="400" |
===== Chemical Vapor Deposition (CVD) =====
=====Chemical Vapor Deposition (CVD)=====

*[[PECVD 1 (PlasmaTherm 790)]]
*[[PECVD 2 (Advanced Vacuum)]]
*[[PECVD 1 (PlasmaTherm 790)]]
*[[ICP-PECVD (Unaxis VLR)]]
*[[PECVD 2 (Advanced Vacuum)]]
*[[Molecular Vapor Deposition]]
*[[ICP-PECVD (Unaxis VLR)]]
*[[Molecular Vapor Deposition]]
*[[Atomic Layer Deposision (Oxford FlexAL)|Atomic Layer Deposition (Oxford FlexAL)]]
*[[Atomic Layer Deposision (Oxford FlexAL)|Atomic Layer Deposition (Oxford FlexAL)]]


|}
|}


= Dry Etch =
=Dry Etch=


{|
{|
|- valign="top"
|- valign="top"
| width="300" |
| width="300" |
===== Reactive Ion Etching (RIE) =====
=====Reactive Ion Etching (RIE)=====
*[[RIE 2 (MRC)]]
*[[RIE 3 (MRC)]]
*[[RIE 5 (PlasmaTherm)]]
*[[Ashers (Technics PEII)]]
*[[Plasma Clean (Gasonics 2000)]]
*[[Plasma Activation (EVG 810)]]
*[[CAIBE (Oxford Ion Mill)]]


*[[RIE 2 (MRC)]]
===== Etch Monitoring =====
*[[RIE 5 (PlasmaTherm)]]
* [[Laser Etch Monitoring]] (Endpoint Detection)

* Optical Emission Spectra
=====Plasma Etching and Cleaning=====
* Residual Gas Analyzer (RGA)

*[[Plasma Clean (YES EcoClean)]]
*[[Plasma Activation (EVG 810)]]
*[[Ashers (Technics PEII)]]

=====Etch Monitoring=====

*[[Laser Etch Monitoring]] (Endpoint Detection)
*Optical Emission Spectra
*Residual Gas Analyzer (RGA)
| width="400" |
| width="400" |
===== ICP-RIE =====
=====ICP-RIE=====
*[[ICP Etch 1 (Panasonic E626I)]]
*[[ICP Etch 2 (Panasonic E640)]]
*[[ICP-Etch (Unaxis VLR)]]
*[[Fluorine ICP Etcher (PlasmaTherm/SLR Fluorine ICP)|Plasma-Therm SLR: Fluorine ICP (PlasmaTherm/SLR Fluorine Etcher)]]
*[[DSEIII (PlasmaTherm/Deep Silicon Etcher)|Plasma-Therm DSE-iii (PlasmaTherm/Deep Silicon Etcher)]]


*[[ICP Etch 1 (Panasonic E646V)]]
===== Other Dry Etching =====
*[[ICP Etch 2 (Panasonic E626I)]]
*[[UV Ozone Reactor]]
*[[Oxford ICP Etcher (PlasmaPro 100 Cobra)]]
*[[XeF2 Etch (Xetch)|XeF<sub>2</sub> Etch (Xetch)]]
*[[Fluorine ICP Etcher (PlasmaTherm/SLR Fluorine ICP)|Fluorine ICP (PlasmaTherm/SLR Fluorine Etcher)]]
*[[DSEIII (PlasmaTherm/Deep Silicon Etcher)|Plasma-Therm DSE-iii (PlasmaTherm/Deep Silicon Etcher)]]

=====Ion Milling and Reactive Ion Beam Etching=====

*[[CAIBE (Oxford Ion Mill)]]
*[[Focused Ion-Beam Lithography (Raith Velion)]]

=====Other Dry Etching=====

*[[UV Ozone Reactor]]
*[[XeF2 Etch (Xetch)|XeF<sub>2</sub> Etch (Xetch)]]
*[[Vapor HF Etch]]
*[[Vapor HF Etch]]


Line 102: Line 133:
|- valign="top"
|- valign="top"
| width="300" |
| width="300" |
* [[Wet Benches]]
*[[Wet Benches]]
**[[Solvent Cleaning Benches]]
**[[Solvent Cleaning Benches]]
**[[Spin Coat Benches]]
**[[Spin Coat Benches]]
**[[Develop Benches]]
**[[Develop Benches]]
**[[Toxic Corrosive Benches]]
**[[Toxic Corrosive Benches]]
**[[Wet Benches#Wafer Toxic Corrosive Benches|Wafer Toxic Corrosive Bench]]
**[[HF/TMAH Processing Benches]]
**[[HF/TMAH Processing Benches]]
**[[Plating Bench]]
**[[Plating Bench]]
| width="400" |
| width="400" |
* [[Gold Plating Bench]]
*[[Gold Plating Bench]]
* [[Critical Point Dryer]]
*[[Critical Point Dryer]]
* [[Spin Rinse Dryer (SemiTool)]]
*[[Spin Rinse Dryer (SemiTool)]]
* [[Chemical-Mechanical Polisher (Logitech)]]
*[[Chemical-Mechanical Polisher (Logitech)]]
*[[Mechanical Polisher (Allied)]]
*[[Automated Coat/Develop System (S-Cubed Flexi)|Auto. Coat/Develop (S-Cubed Flexi)]]
*[https://signupmonkey.ece.ucsb.edu/w/index.php?title=Wet_Benches#Automated_Wet-processing_Spinners_.28POLOS.29 Auto. Wet-Processing Spinners (POLOS)]
|-
|-
|}
|}
Line 121: Line 156:
|- valign="top"
|- valign="top"
| width="400" |
| width="400" |
* [[Rapid Thermal Processor (AET RX6)|Rapid Thermal Annealer/Processor "RTA" (AET RX6)]]
*[[Rapid Thermal Processor (AET RX6)|Rapid Thermal Annealer/Processor "RTA" (AET RX6)]]
* [[Rapid Thermal Processor (SSI Solaris 150)]]
*[[Rapid Thermal Processor (SSI Solaris 150)]]
* [[Tube Furnace (Tystar 8300)]]
*[[Tube Furnace (Tystar 8300)]]
* [[Tube Furnace Wafer Bonding (Thermco)]]
*[[Tube Furnace Wafer Bonding (Thermco)]]
* [[Tube Furnace AlGaAs Oxidation (Lindberg)]]
*[[Tube Furnace AlGaAs Oxidation (Lindberg)]]
* [[Wafer Bonder (SUSS SB6-8E)]]
*[[Wafer Bonder (SUSS SB6-8E)]]
* [[Wafer Bonder (Logitech WBS7)|Wafer Bonder/Wax Mounting (Logitech WBS2)]]
*[[Wafer Bonder (Logitech WBS7)|Wafer Bonder/Wax Mounting (Logitech WBS2)]]
| width="400" |
| width="400" |
* [[Ovens - Overview of All Lab Ovens|Ovens - Overview of all Lab Ovens]]
*[[Ovens - Overview of All Lab Ovens|Ovens - Overview of all Lab Ovens]]
** [[Ovens 1, 2 & 3 (Labline)]]
**[[Ovens 1, 2 & 3 (Labline)]]
** [[Oven 4 (Thermo-Fisher HeraTherm)]]
**[[Oven 4 (Thermo-Fisher HeraTherm)]]
** [[Oven 5 (Labline)]]
**[[Oven 5 (Labline)]]
** [[Vacuum Oven (YES)]]
**[[High Temp Oven (Blue M)]]
** [[High Temp Oven (Blue M)]]
|-
|-
|}
|}


=Packaging=
=Packaging=
''Back-end Fabrication Tools''
* [[Dicing Saw (ADT)]]
{|
* [[Flip-Chip Bonder (Finetech)]]
|
* [[Vacuum Sealer]]
====Die Singulation / Down-sizing====
* [[Wire Saw (Takatori)]]

*[[Dicing Saw (ADT)]]
*[[Wafer Cleaver (PELCO Flip-Scribe)|Manual Wafer Cleaver (PELCO Flipscribe)]]
*[[Automated Wafer Cleaver (Loomis LSD-155LT)]]

====Other Packaging====

*[[Vacuum Sealer]]
|
====Wafer/Die Bonding====

*[[Flip-Chip Bonder (Finetech)]]

*[[Wafer Bonder (SUSS SB6-8E)]]
*[[Wafer Bonder (Logitech WBS7)|Wafer Bonder/Wax Mounting (Logitech WBS2)]]
|}


=Inspection, Test and Characterization=
=Measurement & Characterization=
''[https://en.wikipedia.org/wiki/Metrology Metrology], Electrical/Optical Testing and Thin-Film/Materials [https://en.wikipedia.org/wiki/Characterization_(materials_science) Characterization] tools''
{|
{|
|- valign="top"
|- valign="top"
| width="300" |
| width="300" |
===== Optical/Electron Microscopy =====
=====Optical Microscopy=====
* [[Microscopes|Optical Microscopes]]
* [[Fluorescence Microscope (Olympus MX51)]]
* [[Deep UV Optical Microscope (Olympus)]]
* [[Laser Scanning Confocal M-scope (Olympus LEXT)]]
* [[Photo-emission & IR Microscope (QFI)|Photo-emission & Thermal IR Microscope (QFI)]]
* [[Field Emission SEM 1 (FEI Sirion)]]
* [[Field Emission SEM 2 (JEOL 7600F)]]
* [[SEM Sample Coater (Hummer)]]


*[[Microscopes|Optical Microscopes]] - ''General Use''
===== Topographical Metrology =====
* [[Step Profilometer (KLA Tencor P-7)]]
*[[Fluorescence Microscope (Olympus MX51)]]
*[[Deep UV Optical Microscope (Olympus)]]
* [[Step Profilometer (Dektak 6M)]]
*[[Laser Scanning Confocal M-scope (Olympus LEXT)]]
* [[Atomic Force Microscope (Bruker ICON)|Atomic Force Microsope (Bruker ICON)]]
*[[Digital Microscope (Olympus DSX1000)|Digital Microscope #7 (Olympus DSX1000)]]
* [[Surface Analysis (KLA/Tencor Surfscan)]]
*[[Suss Aligners (SUSS MJB-3)#Backside Alignment|Near-IR Inspection Scope (MJB-IR)]]
** ''Sub-micron Particle Counter''

* [[Laser Scanning Confocal M-scope (Olympus LEXT)]]
=====Electron Microscopy=====
* [[Optical Profilometer - White-Light/Phase-Shift Interference (Filmetrics Profilm3D)]]

*[[SEM 1 (JEOL IT800SHL)]]
*[[Field Emission SEM 2 (JEOL IT800SHL)|SEM 2 (JEOL IT800SHL) w/ EDAX]]
*[[SEM Sample Coater (Hummer)]]

=====Topographical Metrology=====

*[[Step Profilometer (KLA Tencor P-7)]]
*[[Step Profilometer (DektakXT)]]
*[[Atomic Force Microscope (Bruker ICON)|Atomic Force Microsope (Bruker ICON)]]
*[[Laser Scanning Confocal M-scope (Olympus LEXT)]]
| width="400" |
| width="400" |
===== Thin-Film Analysis/Measurement =====
* [[Ellipsometer (Woollam)]]
* [[Film Stress (Tencor Flexus)]]
* [[Filmetrics F40-UV Microscope-Mounted|Optical Film Thickness (Microscope-Mounted Filmetrics F-40-UV)]]
* [[Optical Film Thickness (Filmetrics)|Optical Film Thickness (Filmetrics F20)]]
* [[Optical Film Thickness & Wafer-Mapping (Filmetrics F50)]]
* [[Optical Film Spectra + Optical Properties (Filmetrics F10-RT-UVX)|Reflection/Transmission Spectra & Optical Film Thickness (Filmetrics F10-RT-UVX)]]
* [[Optical Film Thickness (Nanometric)]]
* [[Resistivity Mapper (CDE RESMAP)]]


===== Other Tools =====
=====Thin-Film/Material Analysis=====

* [[Probe Station & Curve Tracer]]
======Thickness + Optical Constants======
* [[Goniometer]]

* [[Photoluminescence PL Setup (Custom)]]
*[[Ellipsometer (Woollam)]]
*[[Filmetrics F40-UV Microscope-Mounted|Optical Film Thickness (Microscope-Mounted Filmetrics F-40-UV)]]
*[[Optical Film Thickness & Wafer-Mapping (Filmetrics F50)]]
*[[Optical Film Spectra + Optical Properties (Filmetrics F10-RT-UVX)|Reflection/Transmission Spectra & Optical Film Thickness (Filmetrics F10-RT-UVX)]]

======Electrical Analysis======

*[[Probe Station & Curve Tracer|Probe Station & Source/Meter Units]]
*[[Resistivity Mapper (CDE RESMAP)]]
*[[IR Thermal Microscope (QFI)|Thermal HotSpot IR Microscope (QFI)]]

======Other Properties======

*[[Film Stress (Tencor Flexus)]]
*[[Surface Analysis (KLA/Tencor Surfscan)|Particle Counts (KLA/Tencor Surfscan)]]
*[[Photoluminescence PL Setup (Custom)]]
|-
|-
|}
|}

== [[Decomissioned Tools]] ==
Click the link above for a list of tools that are no longer available in the lab, but the data is retained for legacy purposes.

Latest revision as of 19:44, 8 January 2025

Lithography

Photoresists and Lithography Chemicals
Contact Aligners (Optical Exposure)
Direct-Write Lithography
Other Patterning Systems
Steppers (Optical Exposure)
Thermal Processing for Photolithography
Lithography Support

Vacuum Deposition

Physical Vapor Deposition (PVD)

Thermal Evaporation
Sputter Deposition
Chemical Vapor Deposition (CVD)

Dry Etch

Reactive Ion Etching (RIE)
Plasma Etching and Cleaning
Etch Monitoring
ICP-RIE
Ion Milling and Reactive Ion Beam Etching
Other Dry Etching

Wet Processing

See the Chemical List page for stocked chemicals such as Developers, Etchants, Solvents etc.

Thermal Processing

Packaging

Back-end Fabrication Tools

Die Singulation / Down-sizing

Other Packaging

Wafer/Die Bonding

Measurement & Characterization

Metrology, Electrical/Optical Testing and Thin-Film/Materials Characterization tools

Optical Microscopy
Electron Microscopy
Topographical Metrology
Thin-Film/Material Analysis
Thickness + Optical Constants
Electrical Analysis
Other Properties

Decomissioned Tools

Click the link above for a list of tools that are no longer available in the lab, but the data is retained for legacy purposes.