Difference between revisions of "Tool List"
Jump to navigation
Jump to search
(→Electron Microscopy: renamed and fixed link for SEM2) |
|||
(96 intermediate revisions by 10 users not shown) | |||
Line 1: | Line 1: | ||
__NOTOC__ | __NOTOC__ | ||
=Lithography= | =Lithography= | ||
+ | |||
{| | {| | ||
− | |-valign="top" | + | |- valign="top" |
− | |width=300| | + | | width="300" | |
− | * [[Suss Aligners (SUSS MJB-3)]] | + | =====Photoresists and Lithography Chemicals===== |
− | * [[ | + | |
− | * [[DUV Flood Expose]] | + | *See the [https://wiki.nanotech.ucsb.edu/w/index.php?title=Lithography_Recipes#Chemicals_Stocked_.2B_Datasheets Chemical Datasheets page]. |
− | * [[ | + | *[[Automated Coat/Develop System (S-Cubed Flexi)|Auto. Coat/Develop (S-Cubed Flexi)]] |
− | * [[ | + | |
− | + | =====Contact Aligners (Optical Exposure)===== | |
− | * [[ | + | |
− | * [[ | + | *[[Suss Aligners (SUSS MJB-3)|Contact Aligners (SUSS MJB-3)]] |
− | * [[Holographic Lith/PL Setup (Custom)]] | + | *[[Contact Aligner (SUSS MA-6)]] |
− | |width=400| | + | *[[DUV Flood Expose]] |
− | * [[Stepper 1 (GCA 6300)]] | + | |
− | * [[Stepper 2 (AutoStep 200)]] | + | =====Direct-Write Lithography===== |
− | * [[Stepper 3 (ASML DUV)]] | + | |
− | * [[ | + | *[[E-Beam Lithography System (JEOL JBX-6300FS)]] |
− | * [[ | + | *[[Field Emission SEM 1 (FEI Sirion)|E-Beam Lithography (FEI Sirion Nabity v9)]] |
− | * [[ | + | *[[Focused Ion-Beam Lithography (Raith Velion)]] |
+ | *[[Maskless Aligner (Heidelberg MLA150)]] | ||
+ | |||
+ | =====Other Patterning Systems===== | ||
+ | |||
+ | *[[Holographic Lith/PL Setup (Custom)|Holographic Litho/PL Setup (Custom)]] | ||
+ | | width="400" | | ||
+ | =====Steppers (Optical Exposure)===== | ||
+ | |||
+ | *[[Stepper 1 (GCA 6300)|Stepper 1 (GCA 6300, i-line)]] | ||
+ | *[[Stepper 2 (AutoStep 200)|Stepper 2 (AutoStep 200, i-line)]] | ||
+ | *[[Stepper 3 (ASML DUV)|Stepper 3 (ASML DUV, Deep-UV)]] | ||
+ | |||
+ | =====Thermal Processing for Photolithography===== | ||
+ | |||
+ | *[[Ovens - Overview of All Lab Ovens|Ovens - Overview of all lab ovens]] | ||
+ | *[[Ovens 1, 2 & 3 (Labline)]] | ||
+ | *[[Oven 4 (Fisher)]] | ||
+ | *[[Oven 5 (Labline)]] | ||
+ | *[[High Temp Oven (Blue M)]] | ||
+ | |||
+ | =====Lithography Support===== | ||
+ | |||
+ | *The [https://wiki.nanotech.ucsb.edu/w/index.php?title=Wet_Benches#Spin_Coat_Benches Spinner Benches] have pre-set hotplates at various temperatures appropriate for common photoresist bakes. | ||
+ | *[https://signupmonkey.ece.ucsb.edu/w/index.php?title=Wet_Benches#Automated_Wet-processing_Spinners_.28POLOS.29 POLOS spinners] on Develop and Solvent benches | ||
+ | *[[Spin Rinse Dryer (SemiTool)|Spin/Rinse/Dryer]] | ||
|- | |- | ||
|} | |} | ||
− | = Vacuum Deposition = | + | =Vacuum Deposition= |
{| | {| | ||
|- valign="top" | |- valign="top" | ||
− | | width="300" | | + | | width="300" | |
− | + | ====Physical Vapor Deposition (PVD)==== | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | + | =====Thermal Evaporation===== | |
− | *[[ | + | |
− | *[[ | + | *[[E-Beam 1 (Sharon)]] |
− | *[[Thermal Evap 1]] | + | *[[E-Beam 2 (Custom)]] |
− | *[[Thermal Evap 2 (Solder)]] | + | *[[E-Beam 3 (Temescal)]] |
− | *[[ | + | *[[E-Beam 4 (CHA)]] |
− | *[[Ion Beam Deposition (Veeco NEXUS)]] | + | *[[E-Beam 5 (Plasys)]] |
− | *[[Molecular Vapor Deposition]] | + | *[[Thermal Evap 1]] |
− | *[[Atomic Layer Deposision (Oxford FlexAL)]] | + | *[[Thermal Evap 2 (Solder)]] |
+ | |||
+ | =====Sputter Deposition===== | ||
+ | |||
+ | *[[Sputter 3 (AJA ATC 2000-F)]] | ||
+ | *[[Sputter 4 (AJA ATC 2200-V)]] | ||
+ | *[[Sputter 5 (AJA ATC 2200-V)]] | ||
+ | *[[Ion Beam Deposition (Veeco NEXUS)]] | ||
+ | *[[SEM Sample Coater (Hummer)]] | ||
+ | |||
+ | | width="400" | | ||
+ | =====Chemical Vapor Deposition (CVD)===== | ||
+ | |||
+ | *[[PECVD 1 (PlasmaTherm 790)]] | ||
+ | *[[PECVD 2 (Advanced Vacuum)]] | ||
+ | *[[ICP-PECVD (Unaxis VLR)]] | ||
+ | *[[Molecular Vapor Deposition]] | ||
+ | *[[Atomic Layer Deposision (Oxford FlexAL)|Atomic Layer Deposition (Oxford FlexAL)]] | ||
|} | |} | ||
− | = Dry Etch = | + | =Dry Etch= |
{| | {| | ||
|- valign="top" | |- valign="top" | ||
− | | width="300" | | + | | width="300" | |
− | *[[RIE 2 (MRC)]] | + | =====Reactive Ion Etching (RIE)===== |
− | *[[RIE 3 (MRC)]] | + | |
− | *[[RIE 5 (PlasmaTherm)]] | + | *[[RIE 2 (MRC)]] |
− | *[[ | + | *[[RIE 3 (MRC)]] |
− | *[[Ashers (Technics PEII)]] | + | *[[RIE 5 (PlasmaTherm)]] |
− | *[[ | + | |
− | * | + | =====Plasma Etching and Cleaning===== |
− | | width="400" | | + | |
− | *[[ICP Etch 1 (Panasonic E626I)]] | + | *[[Plasma Clean (YES EcoClean)]] |
− | *[[ICP Etch 2 (Panasonic E640)]] | + | *[[Plasma Activation (EVG 810)]] |
+ | *[[Ashers (Technics PEII)]] | ||
+ | |||
+ | =====Etch Monitoring===== | ||
+ | |||
+ | *[[Laser Etch Monitoring]] (Endpoint Detection) | ||
+ | *Optical Emission Spectra | ||
+ | *Residual Gas Analyzer (RGA) | ||
+ | | width="400" | | ||
+ | =====ICP-RIE===== | ||
+ | |||
+ | *[[ICP Etch 1 (Panasonic E626I)]] | ||
+ | *[[ICP Etch 2 (Panasonic E640)]] | ||
*[[ICP-Etch (Unaxis VLR)]] | *[[ICP-Etch (Unaxis VLR)]] | ||
− | *[[Plasma | + | *[[Oxford ICP Etcher (PlasmaPro 100 Cobra)]] |
− | *[[XeF2 Etch (Xetch)|XeF<sub>2</sub> Etch (Xetch | + | *[[Fluorine ICP Etcher (PlasmaTherm/SLR Fluorine ICP)|Plasma-Therm SLR: Fluorine ICP (PlasmaTherm/SLR Fluorine Etcher)]] |
− | + | *[[DSEIII (PlasmaTherm/Deep Silicon Etcher)|Plasma-Therm DSE-iii (PlasmaTherm/Deep Silicon Etcher)]] | |
+ | |||
+ | =====Ion Milling and Reactive Ion Beam Etching===== | ||
+ | |||
+ | *[[CAIBE (Oxford Ion Mill)]] | ||
+ | *[[Focused Ion-Beam Lithography (Raith Velion)]] | ||
+ | |||
+ | =====Other Dry Etching===== | ||
+ | |||
+ | *[[UV Ozone Reactor]] | ||
+ | *[[XeF2 Etch (Xetch)|XeF<sub>2</sub> Etch (Xetch)]] | ||
*[[Vapor HF Etch]] | *[[Vapor HF Etch]] | ||
Line 73: | Line 131: | ||
=Wet Processing= | =Wet Processing= | ||
+ | See the [[Chemical List|Chemical List page]] for stocked chemicals such as Developers, Etchants, Solvents etc. | ||
{| | {| | ||
− | |-valign="top" | + | |- valign="top" |
− | |width=300| | + | | width="300" | |
− | * [[Wet Benches]] | + | *[[Wet Benches]] |
**[[Solvent Cleaning Benches]] | **[[Solvent Cleaning Benches]] | ||
**[[Spin Coat Benches]] | **[[Spin Coat Benches]] | ||
**[[Develop Benches]] | **[[Develop Benches]] | ||
**[[Toxic Corrosive Benches]] | **[[Toxic Corrosive Benches]] | ||
+ | **[[Wet Benches#Wafer Toxic Corrosive Benches|Wafer Toxic Corrosive Bench]] | ||
**[[HF/TMAH Processing Benches]] | **[[HF/TMAH Processing Benches]] | ||
**[[Plating Bench]] | **[[Plating Bench]] | ||
− | |width=400| | + | | width="400" | |
− | * [[Gold Plating Bench]] | + | *[[Gold Plating Bench]] |
− | * [[Critical Point Dryer]] | + | *[[Critical Point Dryer]] |
− | * [[Spin Rinse Dryer (SemiTool)]] | + | *[[Spin Rinse Dryer (SemiTool)]] |
− | * [[Chemical-Mechanical Polisher (Logitech)]] | + | *[[Chemical-Mechanical Polisher (Logitech)]] |
+ | *[[Mechanical Polisher (Allied)]] | ||
+ | *[[Automated Coat/Develop System (S-Cubed Flexi)|Auto. Coat/Develop (S-Cubed Flexi)]] | ||
+ | *[https://signupmonkey.ece.ucsb.edu/w/index.php?title=Wet_Benches#Automated_Wet-processing_Spinners_.28POLOS.29 Auto. Wet-Processing Spinners (POLOS)] | ||
|- | |- | ||
|} | |} | ||
=Thermal Processing= | =Thermal Processing= | ||
− | * [[Rapid Thermal Processor (AET RX6)]] | + | {| |
− | * [[ | + | |- valign="top" |
− | * [[Tube Furnace (Tystar 8300)]] | + | | width="400" | |
− | * [[Tube Furnace Wafer Bonding (Thermco)]] | + | *[[Rapid Thermal Processor (AET RX6)|Rapid Thermal Annealer/Processor "RTA" (AET RX6)]] |
− | * [[Tube Furnace AlGaAs Oxidation ( | + | *[[Rapid Thermal Processor (SSI Solaris 150)]] |
− | * [[Wafer Bonder (SUSS SB6-8E)]] | + | *[[Tube Furnace (Tystar 8300)]] |
+ | *[[Tube Furnace Wafer Bonding (Thermco)]] | ||
+ | *[[Tube Furnace AlGaAs Oxidation (Lindberg)]] | ||
+ | *[[Wafer Bonder (SUSS SB6-8E)]] | ||
+ | *[[Wafer Bonder (Logitech WBS7)|Wafer Bonder/Wax Mounting (Logitech WBS2)]] | ||
+ | | width="400" | | ||
+ | *[[Ovens - Overview of All Lab Ovens|Ovens - Overview of all Lab Ovens]] | ||
+ | **[[Ovens 1, 2 & 3 (Labline)]] | ||
+ | **[[Oven 4 (Thermo-Fisher HeraTherm)]] | ||
+ | **[[Oven 5 (Labline)]] | ||
+ | **[[High Temp Oven (Blue M)]] | ||
+ | |- | ||
+ | |} | ||
=Packaging= | =Packaging= | ||
− | * [[Dicing Saw (ADT)]] | + | {| |
− | * [[Flip-Chip Bonder (Finetech)]] | + | | |
− | * [[ | + | ====Die Singulation / Down-sizing==== |
− | * [[ | + | |
+ | *[[Dicing Saw (ADT)]] | ||
+ | *[[Wafer Cleaver (PELCO Flip-Scribe)|Manual Wafer Cleaver (PELCO Flipscribe)]] | ||
+ | *[[Automated Wafer Cleaver (Loomis LSD-155LT)]] | ||
+ | |||
+ | ====Other Packaging==== | ||
+ | |||
+ | *[[Vacuum Sealer]] | ||
+ | | | ||
+ | ====Wafer/Die Bonding==== | ||
+ | |||
+ | *[[Flip-Chip Bonder (Finetech)]] | ||
+ | |||
+ | *[[Wafer Bonder (SUSS SB6-8E)]] | ||
+ | *[[Wafer Bonder (Logitech WBS7)|Wafer Bonder/Wax Mounting (Logitech WBS2)]] | ||
+ | |} | ||
=Inspection, Test and Characterization= | =Inspection, Test and Characterization= | ||
{| | {| | ||
− | |-valign="top" | + | |- valign="top" |
− | |width=300| | + | | width="300" | |
− | * [[ | + | =====Optical Microscopy===== |
− | * [[ | + | |
− | * [[ | + | *[[Microscopes|Optical Microscopes]] - ''General Use'' |
− | * [[ | + | *[[Fluorescence Microscope (Olympus MX51)]] |
− | * [[ | + | *[[Deep UV Optical Microscope (Olympus)]] |
− | * [[ | + | *[[Laser Scanning Confocal M-scope (Olympus LEXT)]] |
− | * [[ | + | *[[Digital Microscope (Olympus DSX1000)|Digital Microscope #7 (Olympus DSX1000)]] |
− | * [[ | + | |
− | * [[ | + | =====Electron Microscopy===== |
− | * [[ | + | |
− | |width=400| | + | *[[SEM 1 (JEOL IT800SHL)]] |
− | * [[ | + | *[[Field Emission SEM 2 (JEOL IT800SHL)|SEM 2 (JEOL IT800SHL) w/ EDAX]] |
− | * [[ | + | *[[SEM Sample Coater (Hummer)]] |
− | * [[ | + | |
− | * [[ | + | =====Topographical Metrology===== |
− | * [[ | + | |
− | * [[ | + | *[[Step Profilometer (KLA Tencor P-7)]] |
− | * [[ | + | *[[Step Profilometer (DektakXT)]] |
− | * [[ | + | *[[Atomic Force Microscope (Bruker ICON)|Atomic Force Microsope (Bruker ICON)]] |
− | * [[ | + | *[[Laser Scanning Confocal M-scope (Olympus LEXT)]] |
− | * [[ | + | | width="400" | |
+ | |||
+ | =====Thin-Film/Material Analysis===== | ||
+ | |||
+ | ======Thickness + Optical Constants====== | ||
+ | |||
+ | *[[Ellipsometer (Woollam)]] | ||
+ | *[[Filmetrics F40-UV Microscope-Mounted|Optical Film Thickness (Microscope-Mounted Filmetrics F-40-UV)]] | ||
+ | *[[Optical Film Thickness & Wafer-Mapping (Filmetrics F50)]] | ||
+ | *[[Optical Film Spectra + Optical Properties (Filmetrics F10-RT-UVX)|Reflection/Transmission Spectra & Optical Film Thickness (Filmetrics F10-RT-UVX)]] | ||
+ | |||
+ | ======Electrical Analysis====== | ||
+ | |||
+ | *[[Resistivity Mapper (CDE RESMAP)]] | ||
+ | *[[Probe Station & Curve Tracer|Probe Station & Source/Meter Units]] | ||
+ | *[[IR Thermal Microscope (QFI)|Photo-emission & Thermal IR Microscope (QFI)]] | ||
+ | |||
+ | ======Other Properties====== | ||
+ | |||
+ | *[[Film Stress (Tencor Flexus)]] | ||
+ | *[[Surface Analysis (KLA/Tencor Surfscan)|Particle Counts (KLA/Tencor Surfscan)]] | ||
+ | *[[Photoluminescence PL Setup (Custom)]] | ||
+ | *[[Goniometer (Rame-Hart A-100)|Goniometer (Ramé-Hart A-100)]] | ||
+ | **''Surface hydrophobicity'' | ||
|- | |- | ||
|} | |} |
Latest revision as of 15:33, 12 September 2023
Lithography
Photoresists and Lithography ChemicalsContact Aligners (Optical Exposure)Direct-Write Lithography
Other Patterning Systems |
Steppers (Optical Exposure)Thermal Processing for Photolithography
Lithography Support
|
Vacuum Deposition
Physical Vapor Deposition (PVD)Thermal Evaporation
Sputter Deposition |
Chemical Vapor Deposition (CVD) |
Dry Etch
Reactive Ion Etching (RIE)Plasma Etching and CleaningEtch Monitoring
|
ICP-RIE
Ion Milling and Reactive Ion Beam EtchingOther Dry Etching |
Wet Processing
See the Chemical List page for stocked chemicals such as Developers, Etchants, Solvents etc.
Thermal Processing
Packaging
Die Singulation / Down-sizingOther Packaging |
Wafer/Die Bonding |
Inspection, Test and Characterization
Optical Microscopy
Electron MicroscopyTopographical Metrology |
Thin-Film/Material AnalysisThickness + Optical Constants
Electrical Analysis
Other Properties |