Difference between revisions of "Tool List"
Jump to navigation
Jump to search
(→Electron Microscopy: renamed and fixed link for SEM2) |
|||
(22 intermediate revisions by 5 users not shown) | |||
Line 12: | Line 12: | ||
=====Contact Aligners (Optical Exposure)===== | =====Contact Aligners (Optical Exposure)===== | ||
− | *[[Suss Aligners (SUSS MJB-3)]] | + | *[[Suss Aligners (SUSS MJB-3)|Contact Aligners (SUSS MJB-3)]] |
*[[Contact Aligner (SUSS MA-6)]] | *[[Contact Aligner (SUSS MA-6)]] | ||
*[[DUV Flood Expose]] | *[[DUV Flood Expose]] | ||
Line 40: | Line 40: | ||
*[[Oven 5 (Labline)]] | *[[Oven 5 (Labline)]] | ||
*[[High Temp Oven (Blue M)]] | *[[High Temp Oven (Blue M)]] | ||
− | |||
=====Lithography Support===== | =====Lithography Support===== | ||
Line 55: | Line 54: | ||
|- valign="top" | |- valign="top" | ||
| width="300" | | | width="300" | | ||
− | + | ====Physical Vapor Deposition (PVD)==== | |
+ | |||
+ | =====Thermal Evaporation===== | ||
*[[E-Beam 1 (Sharon)]] | *[[E-Beam 1 (Sharon)]] | ||
Line 61: | Line 62: | ||
*[[E-Beam 3 (Temescal)]] | *[[E-Beam 3 (Temescal)]] | ||
*[[E-Beam 4 (CHA)]] | *[[E-Beam 4 (CHA)]] | ||
+ | *[[E-Beam 5 (Plasys)]] | ||
*[[Thermal Evap 1]] | *[[Thermal Evap 1]] | ||
*[[Thermal Evap 2 (Solder)]] | *[[Thermal Evap 2 (Solder)]] | ||
Line 70: | Line 72: | ||
*[[Sputter 5 (AJA ATC 2200-V)]] | *[[Sputter 5 (AJA ATC 2200-V)]] | ||
*[[Ion Beam Deposition (Veeco NEXUS)]] | *[[Ion Beam Deposition (Veeco NEXUS)]] | ||
+ | *[[SEM Sample Coater (Hummer)]] | ||
| width="400" | | | width="400" | | ||
Line 95: | Line 98: | ||
=====Plasma Etching and Cleaning===== | =====Plasma Etching and Cleaning===== | ||
− | |||
*[[Plasma Clean (YES EcoClean)]] | *[[Plasma Clean (YES EcoClean)]] | ||
*[[Plasma Activation (EVG 810)]] | *[[Plasma Activation (EVG 810)]] | ||
Line 118: | Line 120: | ||
*[[CAIBE (Oxford Ion Mill)]] | *[[CAIBE (Oxford Ion Mill)]] | ||
+ | *[[Focused Ion-Beam Lithography (Raith Velion)]] | ||
=====Other Dry Etching===== | =====Other Dry Etching===== | ||
Line 137: | Line 140: | ||
**[[Develop Benches]] | **[[Develop Benches]] | ||
**[[Toxic Corrosive Benches]] | **[[Toxic Corrosive Benches]] | ||
+ | **[[Wet Benches#Wafer Toxic Corrosive Benches|Wafer Toxic Corrosive Bench]] | ||
**[[HF/TMAH Processing Benches]] | **[[HF/TMAH Processing Benches]] | ||
**[[Plating Bench]] | **[[Plating Bench]] | ||
Line 166: | Line 170: | ||
**[[Oven 4 (Thermo-Fisher HeraTherm)]] | **[[Oven 4 (Thermo-Fisher HeraTherm)]] | ||
**[[Oven 5 (Labline)]] | **[[Oven 5 (Labline)]] | ||
− | |||
**[[High Temp Oven (Blue M)]] | **[[High Temp Oven (Blue M)]] | ||
− | |||
|- | |- | ||
|} | |} | ||
=Packaging= | =Packaging= | ||
+ | {| | ||
+ | | | ||
+ | ====Die Singulation / Down-sizing==== | ||
*[[Dicing Saw (ADT)]] | *[[Dicing Saw (ADT)]] | ||
+ | *[[Wafer Cleaver (PELCO Flip-Scribe)|Manual Wafer Cleaver (PELCO Flipscribe)]] | ||
+ | *[[Automated Wafer Cleaver (Loomis LSD-155LT)]] | ||
+ | |||
+ | ====Other Packaging==== | ||
+ | |||
+ | *[[Vacuum Sealer]] | ||
+ | | | ||
+ | ====Wafer/Die Bonding==== | ||
+ | |||
*[[Flip-Chip Bonder (Finetech)]] | *[[Flip-Chip Bonder (Finetech)]] | ||
− | *[[ | + | |
− | *[[ | + | *[[Wafer Bonder (SUSS SB6-8E)]] |
+ | *[[Wafer Bonder (Logitech WBS7)|Wafer Bonder/Wax Mounting (Logitech WBS2)]] | ||
+ | |} | ||
=Inspection, Test and Characterization= | =Inspection, Test and Characterization= | ||
Line 185: | Line 201: | ||
=====Optical Microscopy===== | =====Optical Microscopy===== | ||
− | *[[Microscopes|Optical Microscopes]] | + | *[[Microscopes|Optical Microscopes]] - ''General Use'' |
*[[Fluorescence Microscope (Olympus MX51)]] | *[[Fluorescence Microscope (Olympus MX51)]] | ||
*[[Deep UV Optical Microscope (Olympus)]] | *[[Deep UV Optical Microscope (Olympus)]] | ||
*[[Laser Scanning Confocal M-scope (Olympus LEXT)]] | *[[Laser Scanning Confocal M-scope (Olympus LEXT)]] | ||
− | |||
*[[Digital Microscope (Olympus DSX1000)|Digital Microscope #7 (Olympus DSX1000)]] | *[[Digital Microscope (Olympus DSX1000)|Digital Microscope #7 (Olympus DSX1000)]] | ||
=====Electron Microscopy===== | =====Electron Microscopy===== | ||
− | *[[ | + | *[[SEM 1 (JEOL IT800SHL)]] |
− | *[[Field Emission SEM 2 (JEOL | + | *[[Field Emission SEM 2 (JEOL IT800SHL)|SEM 2 (JEOL IT800SHL) w/ EDAX]] |
*[[SEM Sample Coater (Hummer)]] | *[[SEM Sample Coater (Hummer)]] | ||
Line 201: | Line 216: | ||
*[[Step Profilometer (KLA Tencor P-7)]] | *[[Step Profilometer (KLA Tencor P-7)]] | ||
− | *[[Step Profilometer ( | + | *[[Step Profilometer (DektakXT)]] |
*[[Atomic Force Microscope (Bruker ICON)|Atomic Force Microsope (Bruker ICON)]] | *[[Atomic Force Microscope (Bruker ICON)|Atomic Force Microsope (Bruker ICON)]] | ||
− | |||
− | |||
*[[Laser Scanning Confocal M-scope (Olympus LEXT)]] | *[[Laser Scanning Confocal M-scope (Olympus LEXT)]] | ||
| width="400" | | | width="400" | | ||
+ | |||
=====Thin-Film/Material Analysis===== | =====Thin-Film/Material Analysis===== | ||
Line 212: | Line 226: | ||
*[[Ellipsometer (Woollam)]] | *[[Ellipsometer (Woollam)]] | ||
− | |||
*[[Filmetrics F40-UV Microscope-Mounted|Optical Film Thickness (Microscope-Mounted Filmetrics F-40-UV)]] | *[[Filmetrics F40-UV Microscope-Mounted|Optical Film Thickness (Microscope-Mounted Filmetrics F-40-UV)]] | ||
− | |||
*[[Optical Film Thickness & Wafer-Mapping (Filmetrics F50)]] | *[[Optical Film Thickness & Wafer-Mapping (Filmetrics F50)]] | ||
*[[Optical Film Spectra + Optical Properties (Filmetrics F10-RT-UVX)|Reflection/Transmission Spectra & Optical Film Thickness (Filmetrics F10-RT-UVX)]] | *[[Optical Film Spectra + Optical Properties (Filmetrics F10-RT-UVX)|Reflection/Transmission Spectra & Optical Film Thickness (Filmetrics F10-RT-UVX)]] | ||
− | |||
− | |||
− | |||
− | |||
− | |||
======Electrical Analysis====== | ======Electrical Analysis====== | ||
*[[Resistivity Mapper (CDE RESMAP)]] | *[[Resistivity Mapper (CDE RESMAP)]] | ||
− | *[[Probe Station & Curve Tracer]] | + | *[[Probe Station & Curve Tracer|Probe Station & Source/Meter Units]] |
+ | *[[IR Thermal Microscope (QFI)|Photo-emission & Thermal IR Microscope (QFI)]] | ||
− | =====Other | + | ======Other Properties====== |
+ | *[[Film Stress (Tencor Flexus)]] | ||
+ | *[[Surface Analysis (KLA/Tencor Surfscan)|Particle Counts (KLA/Tencor Surfscan)]] | ||
+ | *[[Photoluminescence PL Setup (Custom)]] | ||
*[[Goniometer (Rame-Hart A-100)|Goniometer (Ramé-Hart A-100)]] | *[[Goniometer (Rame-Hart A-100)|Goniometer (Ramé-Hart A-100)]] | ||
**''Surface hydrophobicity'' | **''Surface hydrophobicity'' | ||
− | |||
− | |||
− | |||
|- | |- | ||
|} | |} |
Latest revision as of 15:33, 12 September 2023
Lithography
Photoresists and Lithography ChemicalsContact Aligners (Optical Exposure)Direct-Write Lithography
Other Patterning Systems |
Steppers (Optical Exposure)Thermal Processing for Photolithography
Lithography Support
|
Vacuum Deposition
Physical Vapor Deposition (PVD)Thermal Evaporation
Sputter Deposition |
Chemical Vapor Deposition (CVD) |
Dry Etch
Reactive Ion Etching (RIE)Plasma Etching and CleaningEtch Monitoring
|
ICP-RIE
Ion Milling and Reactive Ion Beam EtchingOther Dry Etching |
Wet Processing
See the Chemical List page for stocked chemicals such as Developers, Etchants, Solvents etc.
Thermal Processing
Packaging
Die Singulation / Down-sizingOther Packaging |
Wafer/Die Bonding |
Inspection, Test and Characterization
Optical Microscopy
Electron MicroscopyTopographical Metrology |
Thin-Film/Material AnalysisThickness + Optical Constants
Electrical Analysis
Other Properties |