Tool List: Difference between revisions

From UCSB Nanofab Wiki
Jump to navigation Jump to search
Content deleted Content added
Zwarburg (talk | contribs)
Dry Etch: Removed ICP#1 from the list - retiring
 
(137 intermediate revisions by 14 users not shown)
Line 1: Line 1:
__NOTOC__
__NOTOC__
{| class="wikitable" style="width:min-content;"
|
=== Tool Categories ===

* [[:Category:Lithography|Lithography]]
* [[:Category:Vacuum Deposition|Deposition]]
* [[:Category:Dry Etch|Dry Etch]]
* [[:Category:Wet Processing|Wet Process]]
* [[:Category:Thermal Processing|Thermal Process]]
* [[:Category:Packaging|Packaging/Bonding]]
* [[Tool List#Measurement .26 Characterization|Metrology/Test]]
|}

=Lithography=
=Lithography=

{|
{|
|-valign="top"
|- valign="top"
|width=300|
| width="300" |
=====Photoresists and Lithography Chemicals=====
* [[Suss Aligners (SUSS MJB-3)]]

* [[IR Aligner (SUSS MJB-3 IR)]]
*See the [https://wiki.nanotech.ucsb.edu/w/index.php?title=Lithography_Recipes#Chemicals_Stocked_.2B_Datasheets Chemical Datasheets page].
* [[DUV Flood Expose]]
*[[Automated Coat/Develop System (S-Cubed Flexi)|Auto. Coat/Develop (S-Cubed Flexi)]]
* [[Ovens 1, 2 & 3 (Labline)]]

* [[Oven 4 (Fisher)]]
=====Contact Aligners (Optical Exposure)=====
* [[Oven 5 (Blue M)]]

* [[Vacuum Oven (YES)]]
*[[Suss Aligners (SUSS MJB-3)|Contact Aligners (SUSS MJB-3)]]
* [[Holographic Lith/PL Setup (Custom)]]
*[[Contact Aligner (SUSS MA-6)]]
|width=400|
* [[Stepper 1 (GCA 6300)]]
*[[DUV Flood Expose]]

* [[Stepper 2 (AutoStep 200)]]
=====Direct-Write Lithography=====
* [[Stepper 3 (ASML DUV)]]

* [[E-Beam Lithography System (JEOL JBX-6300FS)]]
*[[E-Beam Lithography System (Raith EBPG 5150+)]]
* [[Nano-Imprint (Nanonex NX2000)]]
*[[SEM 1 (JEOL IT800SHL)|E-Beam Lithography (Nabity v9)]]
* [[Contact Aligner (SUSS MA-6)]]
*[[Focused Ion-Beam Lithography (Raith Velion)]]
*[[Maskless Aligner (Heidelberg MLA150)]]

=====Other Patterning Systems=====

*[[Holographic Lith/PL Setup (Custom)|Holographic Litho/PL Setup (Custom)]]
| width="400" |
=====Steppers (Optical Exposure)=====

*[[Stepper 1 (GCA 6300)|Stepper 1 (GCA 6300, i-line)]]
*[[Stepper 2 (AutoStep 200)|Stepper 2 (AutoStep 200, i-line)]]
*[[Stepper 3 (ASML DUV)|Stepper 3 (ASML DUV, Deep-UV)]]

=====Thermal Processing for Photolithography=====

*[[Ovens - Overview of All Lab Ovens|Ovens - Overview of all lab ovens]]
*[[Ovens 1, 2 & 3 (Labline)]]
*[[Oven 4 (Fisher)]]
*[[Oven 5 (Labline)]]
*[[High Temp Oven (Blue M)]]

=====Lithography Support=====

*The [https://wiki.nanotech.ucsb.edu/w/index.php?title=Wet_Benches#Spin_Coat_Benches Spinner Benches] have pre-set hotplates at various temperatures appropriate for common photoresist bakes.
*[https://signupmonkey.ece.ucsb.edu/w/index.php?title=Wet_Benches#Automated_Wet-processing_Spinners_.28POLOS.29 POLOS spinners] on Develop and Solvent benches
*[[Spin Rinse Dryer (SemiTool)|Spin/Rinse/Dryer]]
|-
|-
|}
|}


= Vacuum Deposition =
=Vacuum Deposition=


{|
{|
|- valign="top"
|- valign="top"
| width="300" |
| width="300" |
====Physical Vapor Deposition (PVD)====
*[[E-Beam 1 (Sharon)]]
*[[E-Beam 2 (Custom)]]
*[[E-Beam 3 (Temescal)]]
*[[E-Beam 4 (CHA)]]
*[[Sputter 1 (Custom)]]
*[[Sputter 2 (SFI Endeavor)]]
*[[Sputter 3 (AJA ATC 2000-F)]]
*[[Sputter 4 (AJA ATC 2200-V)]]
*[[Sputter 5 (Lesker AXXIS)]]


=====Thermal Evaporation=====
| width="400" |

*[[PECVD 1 (PlasmaTherm 790)]]
*[[PECVD 2 (Advanced Vacuum)]]
*[[E-Beam 1 (Sharon)]]
*[[Thermal Evap 1]]
*[[E-Beam 2 (Custom)]]
*[[Thermal Evap 2 (Solder)]]
*[[E-Beam 3 (Temescal)]]
*[[ICP-PECVD (Unaxis VLR)]]
*[[E-Beam 4 (CHA)]]
*[[Ion Beam Deposition (Veeco NEXUS)]]
*[[E-Beam 5 (Plasys)]]
*[[Molecular Vapor Deposition]]
*[[Thermal Evap 1]]
*[[Atomic Layer Deposision (Oxford FlexAL)]]
*[[Thermal Evap 2 (Solder)]]

=====Sputter Deposition=====

*[[Sputter 3 (AJA ATC 2000-F)]]
*[[Sputter 4 (AJA ATC 2200-V)]]
*[[Sputter 5 (AJA ATC 2200-V)]]
*[[Ion Beam Deposition (Veeco NEXUS)]]
*[[SEM Sample Coater (Hummer)]]

| width="400" |
=====Chemical Vapor Deposition (CVD)=====

*[[PECVD 1 (PlasmaTherm 790)]]
*[[PECVD 2 (Advanced Vacuum)]]
*[[ICP-PECVD (Unaxis VLR)]]
*[[Molecular Vapor Deposition]]
*[[Atomic Layer Deposision (Oxford FlexAL)|Atomic Layer Deposition (Oxford FlexAL)]]


|}
|}


= Dry Etch =
=Dry Etch=


{|
{|
|- valign="top"
|- valign="top"
| width="300" |
| width="300" |
=====Reactive Ion Etching (RIE)=====
*[[RIE 1 (Custom)]]

*[[RIE 2 (MRC)]]
*[[RIE 3 (MRC)]]
*[[RIE 2 (MRC)]]
*[[RIE 5 (PlasmaTherm)]]
*[[RIE 5 (PlasmaTherm)]]

*[[Si Deep RIE (PlasmaTherm/Bosch Etch)]]
=====Plasma Etching and Cleaning=====
*[[Ashers (Technics PEII)]]

*[[UV Ozone Reactor]]
*[[Plasma Clean (YES EcoClean)]]
| width="400" |
*[[ICP Etch 1 (Panasonic E626I)]]
*[[Plasma Activation (EVG 810)]]
*[[ICP Etch 2 (Panasonic E640)]]
*[[Ashers (Technics PEII)]]

*[[ICP-Etch (Unaxis VLR)]]
=====Etch Monitoring=====
*[[Plasma Clean (Gasonics 2000)]]

*[[XeF2 Etch (Xetch)|XeF<sub>2</sub> Etch (Xetch)]]
*[[Laser Etch Monitoring]] (Endpoint Detection)
*[[Plasma Activation (EVG 810)]]
*Optical Emission Spectra
*[[HF Vapor Etch]]
*Residual Gas Analyzer (RGA)
| width="400" |
=====ICP-RIE=====

*[[ICP Etch 2 (Panasonic E626I)]]
*[[Oxford ICP Etcher (PlasmaPro 100 Cobra)]]
*[[Fluorine ICP Etcher (PlasmaTherm/SLR Fluorine ICP)|Fluorine ICP (PlasmaTherm/SLR Fluorine Etcher)]]
*[[DSEIII (PlasmaTherm/Deep Silicon Etcher)|Plasma-Therm DSE-iii (PlasmaTherm/Deep Silicon Etcher)]]

=====Ion Milling and Reactive Ion Beam Etching=====

*[[CAIBE (Oxford Ion Mill)]]
*[[Focused Ion-Beam Lithography (Raith Velion)]]

=====Other Dry Etching=====

*[[UV Ozone Reactor]]
*[[XeF2 Etch (Xetch)|XeF<sub>2</sub> Etch (Xetch)]]
*[[Vapor HF Etch]]


|}
|}


=Wet Processing=
=Wet Processing=
See the [[Chemical List|Chemical List page]] for stocked chemicals such as Developers, Etchants, Solvents etc.
{|
{|
|-valign="top"
|- valign="top"
|width=300|
| width="300" |
* [[Gold Plating Bench]]
*[[Wet Benches]]
* [[Critical Point Dryer]]
**[[Solvent Cleaning Benches]]
* [[Spin Rinse Dryer (SemiTool)]]
**[[Spin Coat Benches]]
**[[Develop Benches]]
* [[Chemical-Mechanical Polisher (Logitech)]]
**[[Toxic Corrosive Benches]]
|width=400|
**[[Wet Benches#Wafer Toxic Corrosive Benches|Wafer Toxic Corrosive Bench]]
* Wet Benches
**[[Acid Benches]]
**[[HF/TMAH Processing Benches]]
**[[Solvent Benches]]
**[[Plating Bench]]
| width="400" |
**[[Photoresist Spin Coat Benches]]
*[[Gold Plating Bench]] (Semcon)
**[[Develop Wet Benches]]
*[[Spin Rinse Dryer (SemiTool)]]
*[[Chemical-Mechanical Polisher (Logitech)]]
*[[Mechanical Polisher (Allied)]]
*[[Automated Coat/Develop System (S-Cubed Flexi)|Auto. Coat/Develop (S-Cubed Flexi)]]
*[https://signupmonkey.ece.ucsb.edu/w/index.php?title=Wet_Benches#Automated_Wet-processing_Spinners_.28POLOS.29 Auto. Wet-Processing Spinners (POLOS)]
|-
|-
|}
|}


=Thermal Processing=
=Thermal Processing=
{|
* [[Rapid Thermal Processor (AET RX6)]]
|- valign="top"
* [[Strip Annealer]]
| width="400" |
* [[Tube Furnace (Tystar 8300)]]
*[[Rapid Thermal Processor (AET RX6)|Rapid Thermal Annealer/Processor "RTA" (AET RX6)]]
* [[Tube Furnace Wafer Bonding (Thermco)]]
*[[Rapid Thermal Processor (SSI Solaris 150)]]
* [[Tube Furnace AlGaAs Oxidation (Linberg)]]
*[[Tube Furnace (Tystar 8300)]]
*[[Tube Furnace Wafer Bonding (Thermco)]]
*[[Tube Furnace AlGaAs Oxidation (Lindberg)]]
*[[Wafer Bonder (SUSS SB6-8E)]]
*[[Wafer Bonder (Logitech WBS7)|Wafer Bonder/Wax Mounting (Logitech WBS2)]]
| width="400" |
*[[Ovens - Overview of All Lab Ovens|Ovens - Overview of all Lab Ovens]]
**[[Ovens 1, 2 & 3 (Labline)]]
**[[Oven 4 (Thermo-Fisher HeraTherm)]]
**[[Oven 5 (Labline)]]
**[[High Temp Oven (Blue M)]]
|-
|}


=Packaging=
=Packaging=
''Back-end Fabrication Tools''
* [[Flip-Chip Bonder (Finetech)]]
{|
* [[Vacuum Sealer]]
|
* [[Dicing Saw (ADT)]]
====Die Singulation / Down-sizing====
* [[Wire Saw (Takatori)]]
* [[Wafer Bonder (SUSS SB6-8E)]]


*[[Dicing Saw (ADT)]]
=Inspection, Test and Characterization=
*[[Wafer Cleaver (PELCO Flip-Scribe)|Manual Wafer Cleaver (PELCO Flipscribe)]]
*[[Automated Wafer Cleaver (Loomis LSD-155LT)]]

====Other Packaging====

*[[Vacuum Sealer]]
|
====Wafer/Die Bonding====

*[[Flip-Chip Bonder (Finetech)]]

*[[Wafer Bonder (SUSS SB6-8E)]]
*[[Wafer Bonder (Logitech WBS7)|Wafer Bonder/Wax Mounting (Logitech WBS2)]]
|}

=Measurement & Characterization=
''[https://en.wikipedia.org/wiki/Metrology Metrology], Electrical/Optical Testing and Thin-Film/Materials [https://en.wikipedia.org/wiki/Characterization_(materials_science) Characterization] tools''
{|
{|
|-valign="top"
|- valign="top"
|width=300|
| width="300" |
=====Optical Microscopy=====
* [[Field Emission SEM 1 (FEI Sirion)]]

* [[Field Emission SEM 2 (JEOL 7600F)]]
*[[Microscopes|Optical Microscopes]] - ''General Use''
* [[Step Profile (Dektak IIA)]]
* [[Step Profilometer (Dektak 6M)]]
*[[Fluorescence Microscope (Olympus MX51)]]
*[[Deep UV Optical Microscope (Olympus)]]
* [[Ellipsometer (Rudolph)]]
*[[Laser Scanning Confocal M-scope (Olympus LEXT)]]
* [[Microscopes]]
*[[Digital Microscope (Olympus DSX1000)|Digital Microscope #7 (Olympus DSX1000)]]
* [[Probe Station & Curve Tracer]]
*[[Suss Aligners (SUSS MJB-3)#Backside Alignment|Near-IR Inspection Scope (MJB-IR)]]
* [[Optical Film Thickness (Filmetrics)]]

* [[Optical Film Thickness (Nanometric)]]
=====Electron Microscopy=====
* [[Goniometer]]

|width=400|
* [[Film Stress (Tencor Flexus)]]
*[[SEM 1 (JEOL IT800SHL)]]
*[[Field Emission SEM 2 (JEOL IT800SHL)|SEM 2 (JEOL IT800SHL) w/ EDAX]]
* [[SEM Sample Coater (Hummer)]]
*[[SEM Sample Coater (Hummer)]]
* [[Surface Analysis (KLA/Tencor Surfscan)]]

* [[Photo-emission & IR Microscope (QFI)]]
=====Topographical Metrology=====
* [[Ellipsometer (Woollam)]]

* [[4-Point Probe Resistivity Mapper]]
*[[Step Profilometer (KLA Tencor P-7)]]
* [[Laser Scanning Confocal M-scope (Olympus LEXT)]]
*[[Step Profilometer (DektakXT)]]
* [[Deep UV Optical Microscope (Olympus)]]
* [[Atomic Force Microsope (Dimension 3100/Nanoscope IVA)]]
*[[Atomic Force Microscope (Bruker ICON)|Atomic Force Microsope (Bruker ICON)]]
*[[Laser Scanning Confocal M-scope (Olympus LEXT)]]
| width="400" |

=====Thin-Film/Material Analysis=====

======Thickness + Optical Constants======

*[[Ellipsometer (Woollam)]]
*[[Filmetrics F40-UV Microscope-Mounted|Optical Film Thickness (Microscope-Mounted Filmetrics F-40-UV)]]
*[[Optical Film Thickness & Wafer-Mapping (Filmetrics F50)]]
*[[Optical Film Spectra + Optical Properties (Filmetrics F10-RT-UVX)|Reflection/Transmission Spectra & Optical Film Thickness (Filmetrics F10-RT-UVX)]]

======Electrical Analysis======

*[[Probe Station & Curve Tracer|Probe Station & Source/Meter Units]]
*[[Resistivity Mapper (CDE RESMAP)]]
*[[IR Thermal Microscope (QFI)|Thermal HotSpot IR Microscope (QFI)]]

======Other Properties======

*[[Film Stress (Tencor Flexus)]]
*[[Surface Analysis (KLA/Tencor Surfscan)|Particle Counts (KLA/Tencor Surfscan)]]
*[[Photoluminescence PL Setup (Custom)]]
|-
|-
|}
|}

== [[Decomissioned Tools]] ==
Click the link above for a list of tools that are no longer available in the lab, but the data is retained for legacy purposes.

Latest revision as of 19:36, 17 February 2026

Tool Categories

Lithography

Photoresists and Lithography Chemicals
Contact Aligners (Optical Exposure)
Direct-Write Lithography
Other Patterning Systems
Steppers (Optical Exposure)
Thermal Processing for Photolithography
Lithography Support

Vacuum Deposition

Physical Vapor Deposition (PVD)

Thermal Evaporation
Sputter Deposition
Chemical Vapor Deposition (CVD)

Dry Etch

Reactive Ion Etching (RIE)
Plasma Etching and Cleaning
Etch Monitoring
ICP-RIE
Ion Milling and Reactive Ion Beam Etching
Other Dry Etching

Wet Processing

See the Chemical List page for stocked chemicals such as Developers, Etchants, Solvents etc.

Thermal Processing

Packaging

Back-end Fabrication Tools

Die Singulation / Down-sizing

Other Packaging

Wafer/Die Bonding

Measurement & Characterization

Metrology, Electrical/Optical Testing and Thin-Film/Materials Characterization tools

Optical Microscopy
Electron Microscopy
Topographical Metrology
Thin-Film/Material Analysis
Thickness + Optical Constants
Electrical Analysis
Other Properties

Decomissioned Tools

Click the link above for a list of tools that are no longer available in the lab, but the data is retained for legacy purposes.