Tool List: Difference between revisions
Jump to navigation
Jump to search
Content deleted Content added
→ICP-RIE: link to Oxford ICP new page |
→Lithography: deleted Stepper 1 |
||
| (43 intermediate revisions by 6 users not shown) | |||
| Line 1: | Line 1: | ||
__NOTOC__ |
__NOTOC__ |
||
{| class="wikitable" style="width:min-content;" |
|||
| ⚫ | |||
=== Tool Categories === |
|||
* [[:Category:Lithography|Lithography]] |
|||
* [[:Category:Vacuum Deposition|Deposition]] |
|||
* [[:Category:Dry Etch|Dry Etch]] |
|||
* [[:Category:Wet Processing|Wet Process]] |
|||
* [[:Category:Thermal Processing|Thermal Process]] |
|||
* [[:Category:Packaging|Packaging/Bonding]] |
|||
* [[Tool List#Measurement .26 Characterization|Metrology/Test]] |
|||
| ⚫ | |||
=Lithography= |
=Lithography= |
||
| Line 7: | Line 20: | ||
=====Photoresists and Lithography Chemicals===== |
=====Photoresists and Lithography Chemicals===== |
||
*See the [https://wiki.nanotech.ucsb.edu/ |
*See the [https://wiki.nanotech.ucsb.edu/w/index.php?title=Lithography_Recipes#Chemicals_Stocked_.2B_Datasheets Chemical Datasheets page]. |
||
*[[Automated Coat/Develop System (S-Cubed Flexi)|Auto. Coat/Develop (S-Cubed Flexi)]] |
*[[Automated Coat/Develop System (S-Cubed Flexi)|Auto. Coat/Develop (S-Cubed Flexi)]] |
||
=====Contact Aligners (Optical Exposure)===== |
=====Contact Aligners (Optical Exposure)===== |
||
*[[Suss Aligners (SUSS MJB-3)]] |
*[[Suss Aligners (SUSS MJB-3)|Contact Aligners (SUSS MJB-3)]] |
||
| ⚫ | |||
*[[Contact Aligner (SUSS MA-6)]] |
*[[Contact Aligner (SUSS MA-6)]] |
||
*[[DUV Flood Expose]] |
*[[DUV Flood Expose]] |
||
| Line 19: | Line 31: | ||
=====Direct-Write Lithography===== |
=====Direct-Write Lithography===== |
||
*[[E-Beam Lithography System ( |
*[[E-Beam Lithography System (Raith EBPG 5150+)]] |
||
*[[ |
*[[SEM 1 (JEOL IT800SHL)|E-Beam Lithography (Nabity v9)]] |
||
*[[Focused Ion-Beam Lithography (Raith Velion)]] |
*[[Focused Ion-Beam Lithography (Raith Velion)]] |
||
*[[Maskless Aligner (Heidelberg MLA150)]] |
*[[Maskless Aligner (Heidelberg MLA150)]] |
||
| Line 30: | Line 42: | ||
=====Steppers (Optical Exposure)===== |
=====Steppers (Optical Exposure)===== |
||
*[[Stepper 1 (GCA 6300)|Stepper 1 (GCA 6300, i-line)]] |
|||
*[[Stepper 2 (AutoStep 200)|Stepper 2 (AutoStep 200, i-line)]] |
*[[Stepper 2 (AutoStep 200)|Stepper 2 (AutoStep 200, i-line)]] |
||
*[[Stepper 3 (ASML DUV)|Stepper 3 (ASML DUV, Deep-UV)]] |
*[[Stepper 3 (ASML DUV)|Stepper 3 (ASML DUV, Deep-UV)]] |
||
| Line 41: | Line 52: | ||
*[[Oven 5 (Labline)]] |
*[[Oven 5 (Labline)]] |
||
*[[High Temp Oven (Blue M)]] |
*[[High Temp Oven (Blue M)]] |
||
*[[Vacuum Oven (YES)]] |
|||
=====Lithography Support===== |
=====Lithography Support===== |
||
*The [https://wiki.nanotech.ucsb.edu/ |
*The [https://wiki.nanotech.ucsb.edu/w/index.php?title=Wet_Benches#Spin_Coat_Benches Spinner Benches] have pre-set hotplates at various temperatures appropriate for common photoresist bakes. |
||
*[https://signupmonkey.ece.ucsb.edu/ |
*[https://signupmonkey.ece.ucsb.edu/w/index.php?title=Wet_Benches#Automated_Wet-processing_Spinners_.28POLOS.29 POLOS spinners] on Develop and Solvent benches |
||
*[[Spin Rinse Dryer (SemiTool)|Spin/Rinse/Dryer]] |
*[[Spin Rinse Dryer (SemiTool)|Spin/Rinse/Dryer]] |
||
|- |
|- |
||
| Line 56: | Line 66: | ||
|- valign="top" |
|- valign="top" |
||
| width="300" | |
| width="300" | |
||
====Physical Vapor Deposition (PVD)==== |
|||
=====Thermal Evaporation===== |
|||
*[[E-Beam 1 (Sharon)]] |
*[[E-Beam 1 (Sharon)]] |
||
| Line 62: | Line 74: | ||
*[[E-Beam 3 (Temescal)]] |
*[[E-Beam 3 (Temescal)]] |
||
*[[E-Beam 4 (CHA)]] |
*[[E-Beam 4 (CHA)]] |
||
| ⚫ | |||
*[[Thermal Evap 1]] |
*[[Thermal Evap 1]] |
||
*[[Thermal Evap 2 (Solder)]] |
*[[Thermal Evap 2 (Solder)]] |
||
| Line 71: | Line 84: | ||
*[[Sputter 5 (AJA ATC 2200-V)]] |
*[[Sputter 5 (AJA ATC 2200-V)]] |
||
*[[Ion Beam Deposition (Veeco NEXUS)]] |
*[[Ion Beam Deposition (Veeco NEXUS)]] |
||
*[[SEM Sample Coater (Hummer)]] |
|||
| width="400" | |
| width="400" | |
||
| Line 91: | Line 105: | ||
*[[RIE 2 (MRC)]] |
*[[RIE 2 (MRC)]] |
||
| ⚫ | |||
*[[RIE 5 (PlasmaTherm)]] |
*[[RIE 5 (PlasmaTherm)]] |
||
=====Plasma Etching and Cleaning===== |
=====Plasma Etching and Cleaning===== |
||
*[[Plasma Clean (Gasonics 2000)]] |
|||
*[[Plasma Clean (YES EcoClean)]] |
*[[Plasma Clean (YES EcoClean)]] |
||
*[[Plasma Activation (EVG 810)]] |
*[[Plasma Activation (EVG 810)]] |
||
| Line 109: | Line 121: | ||
=====ICP-RIE===== |
=====ICP-RIE===== |
||
*[[ICP Etch |
*[[ICP Etch 2 (Panasonic E626I)]] |
||
*[[ICP Etch 2 (Panasonic E640)]] |
|||
*[[ICP-Etch (Unaxis VLR)]] |
|||
*[[Oxford ICP Etcher (PlasmaPro 100 Cobra)]] |
*[[Oxford ICP Etcher (PlasmaPro 100 Cobra)]] |
||
*[[Fluorine ICP Etcher (PlasmaTherm/SLR Fluorine ICP)| |
*[[Fluorine ICP Etcher (PlasmaTherm/SLR Fluorine ICP)|Fluorine ICP (PlasmaTherm/SLR Fluorine Etcher)]] |
||
*[[DSEIII (PlasmaTherm/Deep Silicon Etcher)|Plasma-Therm DSE-iii (PlasmaTherm/Deep Silicon Etcher)]] |
*[[DSEIII (PlasmaTherm/Deep Silicon Etcher)|Plasma-Therm DSE-iii (PlasmaTherm/Deep Silicon Etcher)]] |
||
| Line 119: | Line 129: | ||
*[[CAIBE (Oxford Ion Mill)]] |
*[[CAIBE (Oxford Ion Mill)]] |
||
*[[Focused Ion-Beam Lithography (Raith Velion)]] |
|||
=====Other Dry Etching===== |
=====Other Dry Etching===== |
||
| Line 138: | Line 149: | ||
**[[Develop Benches]] |
**[[Develop Benches]] |
||
**[[Toxic Corrosive Benches]] |
**[[Toxic Corrosive Benches]] |
||
**[[Wet Benches#Wafer Toxic Corrosive Benches|Wafer Toxic Corrosive Bench]] |
|||
**[[HF/TMAH Processing Benches]] |
**[[HF/TMAH Processing Benches]] |
||
**[[Plating Bench]] |
**[[Plating Bench]] |
||
| width="400" | |
| width="400" | |
||
*[[Gold Plating Bench]] |
*[[Gold Plating Bench]] (Semcon) |
||
*[[Critical Point Dryer]] |
|||
*[[Spin Rinse Dryer (SemiTool)]] |
*[[Spin Rinse Dryer (SemiTool)]] |
||
*[[Chemical-Mechanical Polisher (Logitech)]] |
*[[Chemical-Mechanical Polisher (Logitech)]] |
||
*[[Mechanical Polisher (Allied)]] |
*[[Mechanical Polisher (Allied)]] |
||
*[[Automated Coat/Develop System (S-Cubed Flexi)|Auto. Coat/Develop (S-Cubed Flexi)]] |
*[[Automated Coat/Develop System (S-Cubed Flexi)|Auto. Coat/Develop (S-Cubed Flexi)]] |
||
*[https://signupmonkey.ece.ucsb.edu/ |
*[https://signupmonkey.ece.ucsb.edu/w/index.php?title=Wet_Benches#Automated_Wet-processing_Spinners_.28POLOS.29 Auto. Wet-Processing Spinners (POLOS)] |
||
|- |
|- |
||
|} |
|} |
||
| Line 167: | Line 178: | ||
**[[Oven 4 (Thermo-Fisher HeraTherm)]] |
**[[Oven 4 (Thermo-Fisher HeraTherm)]] |
||
**[[Oven 5 (Labline)]] |
**[[Oven 5 (Labline)]] |
||
**[[Vacuum Oven (YES)]] |
|||
**[[High Temp Oven (Blue M)]] |
**[[High Temp Oven (Blue M)]] |
||
| ⚫ | |||
|- |
|- |
||
|} |
|} |
||
=Packaging= |
=Packaging= |
||
''Back-end Fabrication Tools'' |
|||
| ⚫ | |||
| ⚫ | |||
====Die Singulation / Down-sizing==== |
|||
*[[Dicing Saw (ADT)]] |
*[[Dicing Saw (ADT)]] |
||
*[[Wafer Cleaver (PELCO Flip-Scribe)|Manual Wafer Cleaver (PELCO Flipscribe)]] |
|||
| ⚫ | |||
*[[Automated Wafer Cleaver (Loomis LSD-155LT)]] |
|||
| ⚫ | |||
*[[Vacuum Sealer]] |
*[[Vacuum Sealer]] |
||
| |
|||
*[[Wire Saw (Takatori)]] |
|||
====Wafer/Die Bonding==== |
|||
| ⚫ | |||
| ⚫ | |||
*[[Wafer Bonder (Logitech WBS7)|Wafer Bonder/Wax Mounting (Logitech WBS2)]] |
|||
|} |
|||
= |
=Measurement & Characterization= |
||
''[https://en.wikipedia.org/wiki/Metrology Metrology], Electrical/Optical Testing and Thin-Film/Materials [https://en.wikipedia.org/wiki/Characterization_(materials_science) Characterization] tools'' |
|||
{| |
{| |
||
|- valign="top" |
|- valign="top" |
||
| Line 186: | Line 211: | ||
=====Optical Microscopy===== |
=====Optical Microscopy===== |
||
*[[Microscopes|Optical Microscopes]] |
*[[Microscopes|Optical Microscopes]] - ''General Use'' |
||
*[[Fluorescence Microscope (Olympus MX51)]] |
*[[Fluorescence Microscope (Olympus MX51)]] |
||
*[[Deep UV Optical Microscope (Olympus)]] |
*[[Deep UV Optical Microscope (Olympus)]] |
||
*[[Laser Scanning Confocal M-scope (Olympus LEXT)]] |
*[[Laser Scanning Confocal M-scope (Olympus LEXT)]] |
||
| ⚫ | |||
*[[Digital Microscope (Olympus DSX1000)|Digital Microscope #7 (Olympus DSX1000)]] |
*[[Digital Microscope (Olympus DSX1000)|Digital Microscope #7 (Olympus DSX1000)]] |
||
*[[Suss Aligners (SUSS MJB-3)#Backside Alignment|Near-IR Inspection Scope (MJB-IR)]] |
|||
=====Electron Microscopy===== |
=====Electron Microscopy===== |
||
*[[ |
*[[SEM 1 (JEOL IT800SHL)]] |
||
*[[Field Emission SEM 2 (JEOL |
*[[Field Emission SEM 2 (JEOL IT800SHL)|SEM 2 (JEOL IT800SHL) w/ EDAX]] |
||
*[[SEM Sample Coater (Hummer)]] |
*[[SEM Sample Coater (Hummer)]] |
||
| Line 202: | Line 227: | ||
*[[Step Profilometer (KLA Tencor P-7)]] |
*[[Step Profilometer (KLA Tencor P-7)]] |
||
*[[Step Profilometer ( |
*[[Step Profilometer (DektakXT)]] |
||
*[[Atomic Force Microscope (Bruker ICON)|Atomic Force Microsope (Bruker ICON)]] |
*[[Atomic Force Microscope (Bruker ICON)|Atomic Force Microsope (Bruker ICON)]] |
||
| ⚫ | |||
**''Sub-micron Particle Counter'' |
|||
*[[Laser Scanning Confocal M-scope (Olympus LEXT)]] |
*[[Laser Scanning Confocal M-scope (Olympus LEXT)]] |
||
| width="400" | |
| width="400" | |
||
=====Thin-Film/Material Analysis===== |
=====Thin-Film/Material Analysis===== |
||
| Line 213: | Line 237: | ||
*[[Ellipsometer (Woollam)]] |
*[[Ellipsometer (Woollam)]] |
||
*[[Optical Film Thickness (Filmetrics)|Optical Film Thickness (Filmetrics F20)]] |
|||
*[[Filmetrics F40-UV Microscope-Mounted|Optical Film Thickness (Microscope-Mounted Filmetrics F-40-UV)]] |
*[[Filmetrics F40-UV Microscope-Mounted|Optical Film Thickness (Microscope-Mounted Filmetrics F-40-UV)]] |
||
*[[Optical Film Thickness (Nanometric)]] |
|||
*[[Optical Film Thickness & Wafer-Mapping (Filmetrics F50)]] |
*[[Optical Film Thickness & Wafer-Mapping (Filmetrics F50)]] |
||
*[[Optical Film Spectra + Optical Properties (Filmetrics F10-RT-UVX)|Reflection/Transmission Spectra & Optical Film Thickness (Filmetrics F10-RT-UVX)]] |
*[[Optical Film Spectra + Optical Properties (Filmetrics F10-RT-UVX)|Reflection/Transmission Spectra & Optical Film Thickness (Filmetrics F10-RT-UVX)]] |
||
| ⚫ | |||
| ⚫ | |||
| ⚫ | |||
======Electrical Analysis====== |
======Electrical Analysis====== |
||
| ⚫ | |||
*[[Resistivity Mapper (CDE RESMAP)]] |
*[[Resistivity Mapper (CDE RESMAP)]] |
||
| ⚫ | |||
| ⚫ | |||
=====Other |
======Other Properties====== |
||
| ⚫ | |||
*[[Goniometer (Rame-Hart A-100)|Goniometer (Ramé-Hart A-100)]] |
|||
| ⚫ | |||
**''Surface hydrophobicity'' |
|||
| ⚫ | |||
| ⚫ | |||
| ⚫ | |||
| ⚫ | |||
|- |
|- |
||
|} |
|} |
||
== [[Decomissioned Tools]] == |
|||
Click the link above for a list of tools that are no longer available in the lab, but the data is retained for legacy purposes. |
|||
Latest revision as of 18:22, 1 June 2026
Tool Categories |
Lithography
Photoresists and Lithography ChemicalsContact Aligners (Optical Exposure)Direct-Write Lithography
Other Patterning Systems |
Steppers (Optical Exposure)Thermal Processing for Photolithography
Lithography Support
|
Vacuum Deposition
Physical Vapor Deposition (PVD)Thermal Evaporation
Sputter Deposition |
Chemical Vapor Deposition (CVD) |
Dry Etch
Reactive Ion Etching (RIE)Plasma Etching and CleaningEtch Monitoring
|
ICP-RIE
Ion Milling and Reactive Ion Beam EtchingOther Dry Etching |
Wet Processing
See the Chemical List page for stocked chemicals such as Developers, Etchants, Solvents etc.
Thermal Processing
Packaging
Back-end Fabrication Tools
Die Singulation / Down-sizingOther Packaging |
Wafer/Die Bonding |
Measurement & Characterization
Metrology, Electrical/Optical Testing and Thin-Film/Materials Characterization tools
Optical Microscopy
Electron MicroscopyTopographical Metrology |
Thin-Film/Material AnalysisThickness + Optical Constants
Electrical Analysis
Other Properties |
Decomissioned Tools
Click the link above for a list of tools that are no longer available in the lab, but the data is retained for legacy purposes.