Tool List: Difference between revisions

From UCSB Nanofab Wiki
Jump to navigation Jump to search
Content deleted Content added
Silva (talk | contribs)
 
(28 intermediate revisions by 3 users not shown)
Line 1: Line 1:
__NOTOC__
__NOTOC__
{| class="wikitable" style="width:min-content;"
|
=== Tool Categories ===

* [[:Category:Lithography|Lithography]]
* [[:Category:Vacuum Deposition|Deposition]]
* [[:Category:Dry Etch|Dry Etch]]
* [[:Category:Wet Processing|Wet Process]]
* [[:Category:Thermal Processing|Thermal Process]]
* [[:Category:Packaging|Packaging/Bonding]]
* [[Tool List#Measurement .26 Characterization|Metrology/Test]]
|}

=Lithography=
=Lithography=


Line 12: Line 25:
=====Contact Aligners (Optical Exposure)=====
=====Contact Aligners (Optical Exposure)=====


*[[Suss Aligners (SUSS MJB-3)]]
*[[Suss Aligners (SUSS MJB-3)|Contact Aligners (SUSS MJB-3)]]
*[[Contact Aligner (SUSS MA-6)]]
*[[Contact Aligner (SUSS MA-6)]]
*[[DUV Flood Expose]]
*[[DUV Flood Expose]]
Line 18: Line 31:
=====Direct-Write Lithography=====
=====Direct-Write Lithography=====


*[[E-Beam Lithography System (JEOL JBX-6300FS)]]
*[[E-Beam Lithography System (Raith EBPG 5150+)]]
*[[Field Emission SEM 1 (FEI Sirion)|E-Beam Lithography (FEI Sirion Nabity v9)]]
*[[SEM 1 (JEOL IT800SHL)|E-Beam Lithography (Nabity v9)]]
*[[Focused Ion-Beam Lithography (Raith Velion)]]
*[[Focused Ion-Beam Lithography (Raith Velion)]]
*[[Maskless Aligner (Heidelberg MLA150)]]
*[[Maskless Aligner (Heidelberg MLA150)]]
*[[Maskless Aligner (Raith PicoMaster XF)]]


=====Other Patterning Systems=====
=====Other Patterning Systems=====
Line 29: Line 43:
=====Steppers (Optical Exposure)=====
=====Steppers (Optical Exposure)=====


*[[Stepper 1 (GCA 6300)|Stepper 1 (GCA 6300, i-line)]]
*[[Stepper 2 (AutoStep 200)|Stepper 2 (AutoStep 200, i-line)]]
*[[Stepper 2 (AutoStep 200)|Stepper 2 (AutoStep 200, i-line)]]
*[[Stepper 3 (ASML DUV)|Stepper 3 (ASML DUV, Deep-UV)]]
*[[Stepper 3 (ASML DUV)|Stepper 3 (ASML DUV, Deep-UV)]]
Line 62: Line 75:
*[[E-Beam 3 (Temescal)]]
*[[E-Beam 3 (Temescal)]]
*[[E-Beam 4 (CHA)]]
*[[E-Beam 4 (CHA)]]
⚫
*[[E-Beam 5 (Plasys)]]
*[[Thermal Evap 1]]
*[[Thermal Evap 1]]
*[[Thermal Evap 2 (Solder)]]
*[[Thermal Evap 2 (Solder)]]
Line 92: Line 106:


*[[RIE 2 (MRC)]]
*[[RIE 2 (MRC)]]
⚫
*[[RIE 3 (MRC)]]
*[[RIE 5 (PlasmaTherm)]]
*[[RIE 5 (PlasmaTherm)]]


Line 109: Line 122:
=====ICP-RIE=====
=====ICP-RIE=====


*[[ICP Etch 1 (Panasonic E626I)]]
*[[ICP Etch 2 (Panasonic E626I)]]
*[[ICP Etch 2 (Panasonic E640)]]
*[[ICP-Etch (Unaxis VLR)]]
*[[Oxford ICP Etcher (PlasmaPro 100 Cobra)]]
*[[Oxford ICP Etcher (PlasmaPro 100 Cobra)]]
*[[Fluorine ICP Etcher (PlasmaTherm/SLR Fluorine ICP)|Plasma-Therm SLR: Fluorine ICP (PlasmaTherm/SLR Fluorine Etcher)]]
*[[Fluorine ICP Etcher (PlasmaTherm/SLR Fluorine ICP)|Fluorine ICP (PlasmaTherm/SLR Fluorine Etcher)]]
*[[DSEIII (PlasmaTherm/Deep Silicon Etcher)|Plasma-Therm DSE-iii (PlasmaTherm/Deep Silicon Etcher)]]
*[[DSEIII (PlasmaTherm/Deep Silicon Etcher)|Plasma-Therm DSE-iii (PlasmaTherm/Deep Silicon Etcher)]]


Line 139: Line 150:
**[[Develop Benches]]
**[[Develop Benches]]
**[[Toxic Corrosive Benches]]
**[[Toxic Corrosive Benches]]
**[[Wet Benches#Wafer Toxic Corrosive Benches|Wafer Toxic Corrosive Bench]]
**[[HF/TMAH Processing Benches]]
**[[HF/TMAH Processing Benches]]
**[[Plating Bench]]
**[[Plating Bench]]
| width="400" |
| width="400" |
*[[Gold Plating Bench]]
*[[Gold Plating Bench]] (Semcon)
*[[Critical Point Dryer]]
*[[Spin Rinse Dryer (SemiTool)]]
*[[Spin Rinse Dryer (SemiTool)]]
*[[Chemical-Mechanical Polisher (Logitech)]]
*[[Chemical-Mechanical Polisher (Logitech)]]
Line 173: Line 184:


=Packaging=
=Packaging=
''Back-end Fabrication Tools''
{|
{|
|
|
Line 178: Line 190:


*[[Dicing Saw (ADT)]]
*[[Dicing Saw (ADT)]]
*[[Wafer Cleaver (PELCO Flip-Scribe)|Wafer Cleaver (PELCO Flipscribe)]]
*[[Wafer Cleaver (PELCO Flip-Scribe)|Manual Wafer Cleaver (PELCO Flipscribe)]]
*[[Automated Wafer Cleaver (Loomis LSD-155LT)]]


====Other Packaging====
====Other Packaging====
Line 192: Line 205:
|}
|}


=Inspection, Test and Characterization=
=Measurement & Characterization=
''[https://en.wikipedia.org/wiki/Metrology Metrology], Electrical/Optical Testing and Thin-Film/Materials [https://en.wikipedia.org/wiki/Characterization_(materials_science) Characterization] tools''
{|
{|
|- valign="top"
|- valign="top"
| width="300" |
| width="300" |
=====Optical Microscopy=====
==== <big>Inspection</big> ====

=====Microscopes 🔬=====


*[[Microscopes|Optical Microscopes]] - ''General Use''
*[[Microscopes|Optical Microscopes]] - ''General Use''
Line 202: Line 218:
*[[Deep UV Optical Microscope (Olympus)]]
*[[Deep UV Optical Microscope (Olympus)]]
*[[Laser Scanning Confocal M-scope (Olympus LEXT)]]
*[[Laser Scanning Confocal M-scope (Olympus LEXT)]]
⚫
*[[Photo-emission & IR Microscope (QFI)|Photo-emission & Thermal IR Microscope (QFI)]]
*[[Digital Microscope (Olympus DSX1000)|Digital Microscope #7 (Olympus DSX1000)]]
*[[Digital Microscope (Olympus DSX1000)|Digital Microscope #7 (Olympus DSX1000)]]
*[[Suss Aligners (SUSS MJB-3)#Backside Alignment|Near-IR Inspection Scope (MJB-IR)]]


=====Electron Microscopy=====
=====Electron Microscopes 🦠=====


*[[Field Emission SEM 1 (FEI Sirion)]]
*[[SEM 1 (JEOL IT800SHL)]]
*[[Field Emission SEM 2 (JEOL 7600F)]]
*[[Field Emission SEM 2 (JEOL IT800SHL)|SEM 2 (JEOL IT800SHL) w/ EDAX]]
*[[SEM Sample Coater (Hummer)]]
*[[SEM Sample Coater (Hummer)]]


=====Topographical Metrology=====
=====Topology / Profilometer 🏔️=====


*[[Step Profilometer (KLA Tencor P-7)]]
*[[Step Profilometer (KLA Tencor P-7)]]
*[[Step Profilometer (Dektak 6M)]]
*[[Step Profilometer (DektakXT)]]
*[[Atomic Force Microscope (Bruker ICON)|Atomic Force Microsope (Bruker ICON)]]
*[[Atomic Force Microscope (Bruker ICON)|Atomic Force Microsope (Bruker ICON)]]
*[[Laser Scanning Confocal M-scope (Olympus LEXT)]]
*[[Laser Scanning Confocal M-scope (Olympus LEXT)]]
| width="400" |
| width="400" |
=====Thin-Film/Material Analysis=====
==== <big>Thin-Film/Material Analysis</big> ====


======Thickness + Optical Constants======
======Optical 🔦======


*[[Ellipsometer (Woollam)]]
*[[Ellipsometer (Woollam)]]
Line 227: Line 243:
*[[Optical Film Spectra + Optical Properties (Filmetrics F10-RT-UVX)|Reflection/Transmission Spectra & Optical Film Thickness (Filmetrics F10-RT-UVX)]]
*[[Optical Film Spectra + Optical Properties (Filmetrics F10-RT-UVX)|Reflection/Transmission Spectra & Optical Film Thickness (Filmetrics F10-RT-UVX)]]


======Electrical Analysis======
======Electrical ⚡️======


⚫
*[[Resistivity Mapper (CDE RESMAP)]]
*[[Probe Station & Curve Tracer|Probe Station & Source/Meter Units]]
*[[Probe Station & Curve Tracer|Probe Station & Source/Meter Units]]
⚫
*[[Resistivity Mapper (CDE RESMAP)]]
⚫
*[[IR Thermal Microscope (QFI)|Thermal HotSpot IR Microscope (QFI)]]


======Other Properties======
======Other 🔍======


*[[Film Stress (Tencor Flexus)]]
*[[Film Stress (Tencor Flexus)]]
*[[Surface Analysis (KLA/Tencor Surfscan)|Particle Counts (KLA/Tencor Surfscan)]]
*[[Surface Analysis (KLA/Tencor Surfscan)|Particle Counts (KLA/Tencor Surfscan)]]
*[[Photoluminescence PL Setup (Custom)]]
*[[Photoluminescence PL Setup (Custom)]]
*[[Goniometer (Rame-Hart A-100)|Goniometer (Ramé-Hart A-100)]]
**''Surface hydrophobicity''
|-
|-
|}
|}

== [[Decomissioned Tools]] ==
Click the link above for a list of tools that are no longer available in the lab, but the data is retained for legacy purposes.

Latest revision as of 23:38, 6 November 2026

Tool Categories

Lithography

Photoresists and Lithography Chemicals
Contact Aligners (Optical Exposure)
Direct-Write Lithography
Other Patterning Systems
Steppers (Optical Exposure)
Thermal Processing for Photolithography
Lithography Support

Vacuum Deposition

Physical Vapor Deposition (PVD)

Thermal Evaporation
Sputter Deposition
Chemical Vapor Deposition (CVD)

Dry Etch

Reactive Ion Etching (RIE)
Plasma Etching and Cleaning
Etch Monitoring
ICP-RIE
Ion Milling and Reactive Ion Beam Etching
Other Dry Etching

Wet Processing

See the Chemical List page for stocked chemicals such as Developers, Etchants, Solvents etc.

Thermal Processing

Packaging

Back-end Fabrication Tools

Die Singulation / Down-sizing

Other Packaging

Wafer/Die Bonding

Measurement & Characterization

Metrology, Electrical/Optical Testing and Thin-Film/Materials Characterization tools

Inspection

Microscopes 🔬
Electron Microscopes 🦠
Topology / Profilometer 🏔️

Thin-Film/Material Analysis

Optical 🔦
Electrical ⚡️
Other 🔍

Decomissioned Tools

Click the link above for a list of tools that are no longer available in the lab, but the data is retained for legacy purposes.